Laserfiche WebLink
included in each FUA were applied in the calculation of the space breakdowns. A <br />comparative space utilization analysis was undertaken as part of the review of the <br />physical characteristics of each institution. <br />The FUA's considered in the facility evaluation are those generic spaces found in <br />detention type facilities. The 14 FUA's allow a facility containing numerous differing <br />spaces to be categorized and compared, averaged, and described. The FUA's <br />reviewed in the detention facilities are the following: (1) administration area, (2) public <br />lobby area, (3) visiting, (4) Central Control, (5) maintenance/storage/utility, (6) food <br />service, (7) laundry, (8) intake / release, (9) medical, (10) programs / classrooms, <br />(11) housing / dayrooms, (12) circulation, (13) quasi -outdoor recreation, and (14) <br />vehicle sallyport. <br />Standard Building and Design Criteria: This review and assessment involved <br />surveying the Jail for (1) appropriate size and efficiency, expansion, capabilities, <br />location and adjacencies of departments, (2) systems - HVAC, plumbing, electrical <br />and lighting, (3) fire and life safety - fire sprinklers, smoke detectors, alarms and <br />panels, doors, emergency lighting, fire resistive materials, furniture and equipment, <br />(4) codes and standards including ADA standards, (5) maintenance — interior / <br />exterior structure, systems, grounds, (6) site - landscaping, parking, handicapped <br />access, walks, curbs, and drainage, (7) structure - exterior walls, roof, foundations, <br />windows, doors, overhangs and chimneys, (8) infrastructure - interior walls, Floors, <br />ceilings, finishes, stairs, hand rails, locks, hardware, and flues, and (9) energy <br />conservation - orientation, glazing, insulation, and shading. <br />The review focused on the following areas and issues outlined in the chart on the top <br />of the following page. The chart shows building components and conditions, as well <br />as system components and conditions the assessment considered. <br />Building Component <br />Condition <br />Roof <br />Leaks, bubbles, cracks, loose tiles. <br />Exterior Walls <br />Cracks, condition of surface <br />Structure <br />Visible signs of structural problems; cracks <br />in walls, floors or ceilings. <br />Windows <br />Operate and lock properly, glazing, <br />sealants. <br />Doors <br />Operate and lock properly. <br />Interior: Floors <br />ComponentSystem <br />Condition of surface, cracks. <br />Interior: Walls <br />Non-structural cracks, condition of surface. <br />Interior: Ceilings <br />Cracks, condition of surface. <br />Heating, Ventilation, and <br />Operation, reliability, level of maintenance <br />Air Conditioning <br />required / available. <br />Appendix B. <br />65A-148 <br />