My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SIEMENS MASTER SERVICES
Clerk
>
Contracts / Agreements
>
S
>
SIEMENS MASTER SERVICES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2019 11:18:01 AM
Creation date
3/25/2019 12:36:45 PM
Metadata
Fields
Template:
Contracts
Company Name
SIEMENS MASTER SERVICES
Contract #
A-2019-035
Agency
POLICE
Council Approval Date
3/5/2019
Expiration Date
11/8/2020
Insurance Exp Date
10/1/2019
Destruction Year
2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIEMENS <br />Restroom Bulldine/Concession Next to the Street <br />• Install two (2) network fixed cameras on the roofs edge viewing each corners of the park <br />towards the bleachers. <br />Install two (2) network fixed cameras on the roof edge viewing the street parking and <br />building facingtowards the street <br />• Install rigid conduit where it is exposed on the exteriorof the building. All indoor conduits <br />may be EMT. <br />Install one (1) outdoor loud speaker on the side of the building facing towards the street <br />Install on a custom roof pole mount two (2) Ubiquiti radio links, one (1) pointing to the high <br />light pole next to bleachers, one (1) pointing to the community center swimming pool <br />building. <br />• Install Cat6 cable to the cameras and the loud speaker from the IDF enclosure. <br />• install Inside the building electrical panel room on a fire rated hackhoard, a vertical low <br />profile IDF enclosure, server, PoE switch and other miscellaneous Items inside the <br />enclosure. Provide Inside the IDF enclosure a 120vac quad outlet on a dedicated 20amp <br />circuit. <br />1. All required fire stopping shall be UL listed 3M Fire barrier Caulk or 4hr, UL rated <br />equivalent is required. Retain one (1) used cartridge for documentation. <br />2. Each pole and field enclosure location shall be interconnected via conduit <br />3. All outdoor equipment shall be weather proofed to protect devices, cabling and structures <br />from the outdoor elements. <br />4. All risers and lateral connections into the field enclosures, both Security and IT/Telecom <br />enclosures shall be schedule 80 rigid steel construction. <br />S. Conduit elbows may be schedule 80 PVC construction, assuming the connection to steel <br />risers occurs within the concrete foundation. Any conduit elbows that are notembedded <br />within a concrete foundation shall be schedule 80 and rigid steel construction. <br />6. All above ground conduit shall be galvanized rigid steel unless otherwise noted. <br />7. Conduit runs shall allow for 50% additional capacity. All conduits shall have a "pull string" <br />installed and remain for future use. <br />8. All work shall meet or exceed the latest requirements of all national, state, county and <br />municipal codes. <br />9. All required permits and Inspection certificates shall be provided by others. <br />10. All work shall conform to the National Electrical Code, National Fire Codes, NFPA Life Safety <br />Code and other local codes. <br />General Terms & Conditions: <br />11, Prior to any daily work being conducted, a safety tailboard meeting shall be conducted with <br />all contractors and site personnel. This training will be re -conducted every time there are <br />new personnel working on site. <br />11 Ali affiliates of the contractor shall dress inappropriate work attire hearing their respective <br />company logo for recognition. When working at the Police Department all affiliates of the <br />contractor shall report to CDC, for sign In and temporary badging for the day. They must <br />Page 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.