Laserfiche WebLink
the transportation solutions company... <br />INTERSECTION: 2 ALTERNATIVE: Existing Conditions <br />INTERSECTION NAME: Broadway/Santa Clara Avenue <br />NORTH/SOUTH: Broadway <br />EAST/WEST:Santa Clara Avenue <br />Right <br />Turn # of Turn Lanegroup <br />Mvmt. Lanes Cond. Capacity Vol. V/C Vol. V/C <br />NBL 0.0 0 0 0.00 * 0 0.00 * <br />NBT 2.0 3,400 295 0.19 620 0.31 <br />NBR 0.0 P 0 342 0.00 420 0.00 <br />SBL 1.0 1,600 37 0.02 97 0.06 <br />SBT 2.0 3,400 1,459 0.43 * 1,307 0.38 * <br />SBR 0.0 P 0 0 0.00 0 0.00 <br />EBL 0.0 0 134 0.00 144 0.00 <br />EBT 1.0 1,700 321 0.38 * 233 0.26 * <br />EBR 0.0 P 0 193 0.00 67 0.00 <br />WBL 1.0 1,600 76 0.05 * 90 0.06 * <br />WBT 0.0 0 0 0.00 0 0.00 <br />WBR 1.0 P 1,600 6 0.00 14 0.00 <br />N/S Critical Movements 0.43 0.38 <br />E/W Critical Movements 0.43 0.32 <br />Right Turn Critical Movement 0.00 0.00 <br />Clearance Interval 0.05 0.05 <br />ICU 0.908 0.751 <br />Level of Service (LOS)E C <br />Notes: ICU - Intersection Capacity Utilization <br />V/C - Volume to Capacity Ratio <br />Right Turn Conditions: <br />F - Free Right Turn <br />O - Overlap Phase <br />P - Permitted Right Turn <br />N - No Right Turn on Red <br />Existing Conditions <br />AM Peak Hour PM Peak Hour <br /> D:\Projects\RE - 2525 Main Street\Analysis Offset September 2019 Revised\ICU Worksheet 2\Existing 22-401