Kleinfelder Statement of Quahficiltions for On -Call Material Testing and Special Inspection Services <br />for City of Santa Ana, RFP No. 20-111 <br />Site grading <br />Foundation excavations <br />Backfill placement <br />* Subgrade preparation <br />* Pile driving <br />Drilled pier construction <br />* Rock anchor placement <br />Precast concrete inspection <br />* Welding inspection <br />Concrete paving Masonry construction <br />Reinforcement placement * High strength bolting <br />* Batch plant inspection <br />* Concrete placement <br />M Asphalt paving <br />Soil improvement <br />Load tests <br />A Steel construction <br />* Painting <br />s Expansion bolting <br />* Drainage systems <br />Field instrumentation <br />* Underpinning <br />* Source inspection <br />s Fabrication shop <br />inspection <br />Listed below are the standard materials testing and inspection services which we expect to perform <br />on this contract and have provided for similar on -call contracts - <br />Soil and Aggregate Sampling and Testing. Our certified technicians will sample soil and aggregate <br />using ASTM Standard Practice D75 for the appropriate laboratory testing, which may include sieve <br />analysis, sand equivalent, cleanness value, K-value, maximum density, specific gravity, durability, <br />soundness, and expansion potential. <br />Bituminous Mixture Sampling and Testing. Our certified technicians will sample asphalt concrete <br />mixtures in the field or at the batch plant using ASTM D979 for laboratory testing which may include <br />maximum theoretical unit weight, asphalt extraction, stability, moisture and rutting susceptibility, and <br />gradation analysis. <br />Soil and Base Compaction Testing. Our certified technicians observe placement of soils and <br />aggregate base material and conduct field testing using a nuclear gauge device or sand cone to <br />evaluate the in -place density and moisture of the material and to calculate relative compaction. <br />7'4, 1%.i It 3,a ',,.a A:w;'i'I %V4 .,yapafln,.''r,r f, o,t l;a•n,Vre_ m r4, w, tr rO on T',s, dap l,:"n^ A9 <br />:, , Im Uf C,3 la r- G ,r mna. TJ I TOL r. I v o• a. r r0 ,ays „ m 14 ry, <br />Micro -surfacing and Slurry Seal. Our certified technicians observe the placement of slurry seal, <br />scrub seal and micro -surfacing materials for resurfacing of the existing roadways. They check for <br />oversize material, monitor mix temperature, proper mixing, and blending of the mix. Our inspectors <br />can also collect samples of slurry seal for wet -track abrasion testing. <br />Asphalt Compaction Testing. Our certified technicians observe placement and compaction of HMA <br />material using nuclear density gauges in accordance with California Test Method 375. al.,n,. is : f <br />,u'„>':n^,iL:d,I AR: U n r.alir•,3 „r,a•s. wy;;,r. ,......m:,r,.,"„r.,m•W,,.,lno.t.,iir,ior.•fi`,tlyr <br />r„a-;„,g r, ir,.a_'0 'as',,,v ar^,r ollIII )no .i v I „ "+I ,j a'S... <br />Asphalt Batch Plant Inspection. Our certified technicians routinely provide batch plant inspection <br />during paving operations to observe and document material quantities, mixing temperatures, binder <br />type and temperatures. They collect samples of asphalt and aggregates and conduct moisture tests <br />and grain sire analysis. They also ticket the load for identification by the field inspector. <br />Concrete Batch Plant Inspection. Our certified technicians perform observation and documentation <br />of procedures used in concrete batching. At the batch plant, the inspector monitors and records <br />weights of ingredients for concrete, including admixtures. They also monitor mixing of concrete. <br />slump, addition of water, and adherence to the approved mix design. They will ticket the load for <br />identification by the field inspector. <br />Inspection of Reinforcing Steel at the Fabrication Plant. Our deputy inspectors identify and <br />sample reinforcing steel at the fabrication plant and tag the steel for recognition upon arrival at the <br />project site. We also collect samples of reinforcing steel which are transported to our facility for <br />laboratory testing (bend and tensile) as required by the project plans and specifications. <br />City Council <br />21 — 108 <br />1� to <br />716/2021 <br />