My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NATIONAL CORROSION (4)
Clerk
>
Contracts / Agreements
>
N
>
NATIONAL CORROSION (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2024 2:41:34 PM
Creation date
3/14/2022 3:50:53 PM
Metadata
Fields
Template:
Contracts
Company Name
NATIONAL CORROSION
Contract #
N-2022-069
Agency
Public Works
Expiration Date
3/15/2023
Insurance Exp Date
10/15/2023
Destruction Year
2028
Notes
For Insurance Exp. Date see Notice of Compliance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
National Corrosion <br />www.notional-corrosion.com <br />Pipe support assessment <br />• Corrosion potentials of supports and pipeline potentials <br />• Upstream and downstream soil -to -air interface descriptions <br />• Dry film thickness (Coating) at locations 12, 3, 6, and 9 o clock <br />• UT (Ultrasonic) measurements at locations 12, 3, 6, and 9 o clock <br />• Insulator potentials and AC potential <br />• Water depth <br />• Photographs with info <br />• Sub -meter GPS coordinates <br />• Corrosion Severity Code (Define and classify priority actions) <br />o Perform atmospheric assessments at key locations <br />o Conduct current requirement testing to verify current needed to bring pipe -to - <br />soil potentials up to NACE criteria. <br />o Create a scope of work for improvements or repairs required to improve <br />corrosion assessment. <br />o Verify the existence and location of stray DC currents affecting the pipelines at <br />locations near foreign impressed current cathodic protection systems. <br />o Test and verify dielectric isolation from foreign structures. <br />o All data to be ArcGIS compatible <br />o Create coating specifications and repair procedures <br />Task 3 —Integrate testing data into ArcGIS system <br />Field testing data will be recorded in a format compatible with ArcGIS. If ArcGIS implementation <br />is approved, then all data will be uploaded to a server. All activity will actively update during <br />repairs or modifications and the condition of facilities can be monitored remotely. <br />ArcGIS data will be recorded in a method that will aid estimation of coating and <br />mechanical repairs. <br />• All locations for repair will be prioritized and backed up with data <br />Task 4—Corrosion Report (Deliverable) <br />After all field testing, inspection, and analysis is complete, a drafted report will be prepared <br />including the following: <br />• Description of testing procedures and tabulation of data <br />• Summary of test points showing GIS Coordinates along with identification <br />• Site photos <br />• Evaluation and assessment of active corrosion, status, and operational condition. <br />• Conclusions on as -found conditions <br />• Calculation of remaining life expectancy <br />• Prioritized recommendations of repairs or replacements. <br />• System operation and maintenance procedures <br />• Corrosion control plan to address immediate and long-term requirements <br />• Prepare a list of other cathodic protection systems owned by others that may cause <br />interference or require a coordination of efforts. <br />
The URL can be used to link to this page
Your browser does not support the video tag.