<br />City of Santa Ana RFP 22-068 <br />Page 15 <br />DOOR BOARDING SPECIFICATIONS <br /> <br />NOTES: <br />1. IRON DOORS OR FRAMES MAY BE REMOVED AND STORED INSIDE BUILDING IF <br />NECESSARY. <br />2. USE 3/8" X 12" CARRIAGE BOLTS - ROUNDED HEAD ON OUTSIDE OF BUILDING. <br />LONGER BOLTS MAY BE NECESSARY. <br />3. TIGHTEN NUTS FROM INSIDE ENOUGH TO SLIGHTLY COMPRESS 2X4 BRACE. <br />4. IF PLYWOOD CAN NOT BE BUTTED AGAINST BAND MOLDING, CUT TO COVER <br />OUTSIDE EDGE OF DOOR FRAME. <br />5. BOLT HOLES ARE LOCATED AS THEY ARE FOR WINDOWS (SEE WINDOW DETAIL) <br />6. CENTER BRACE LOCATED IN CENTER OF DOORWAY OPENING. TOP AND BOTTOM <br />BRACES ARE POSITIONED WHERE A = 1/2B (SEE DIMENSION LOCATIONS ON <br />DRAWING) <br />7. USE 2X4 BOTTOM BRACE - CUT TO WIDTH OF DOOR TRIM. DRILL TO THE FLOOR <br />TO PREVENT OPENING. INTERIOR AND EXTERIOR BOTTOM BRACES WITH <br />MASONRY SCREWS ARE MANDATORY WHEN BOARDING GARAGE DOORS. <br /> <br /> <br /> <br />City Council 29 –18 6/21/2022