Laserfiche WebLink
BUILDING COMPOSITE PLAN NOTES <br />1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, <br />ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO <br />THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. <br />2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE <br />LEGAL ADDRESS. <br />3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE ALL TO ALL <br />AD-01 AD-02.1 <br />4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. <br />5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. <br />6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON AD XX <br />7. THE FLAME -SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY <br />8. WITH CBC 803. <br />9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. <br />10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, <br />PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE -RATED ASSEMBLIES PROVIDE FIRE -RATED <br />ACCESS PANELS WITH SELF CLOSING DEVICES. <br />11. PROVIDE ACOUSTICAL ASSEMBLIES PER ALL <br />AD-20 <br />12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. <br />18 <br />13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER AD-22 <br />I I <br />14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. <br />ELEV Al <br />ELEV Al <br />I <br />i <br />h <br />1_ <br />I I <br />15. SEE STRUCTURAL DRAWINGS FOR: <br />A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING <br />VX ///I <br />_ <br />I <br />B) SPECIAL NAILING AND BLOCKING REQUIREMENTS <br />I I <br />I <br />15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR <br />I I <br />i <br />i i <br />I <br />BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM <br />------t-----J <br />I I <br />IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING <br />PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE <br />I <br />I <br />VENTILATED. IN FIRE -RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER <br />PROTECTION SHALL BE EXTENDED TO THOSE AREAS. <br />L---------------- --J <br />L------- <br />I <br />L------- -- <br />---- --_J �_____� <br />16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR <br />U) <br />IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL <br />IF -1I <br />3 <br />ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED <br />AND APPROVED. <br />L _ —1 <br />i I <br />1 <br />I <br />i <br />I <br />17. PARKING GARAGE TYPE -IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE -RESISTIVE CONSTRUCTION <br />— <br />_ <br />THROUGHOUT. <br />- - <br />3Y j <br />18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) <br />19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE 6 <br />PROTECTION PER <br />AD 31 <br />i <br />; ELEV A2 <br />ELEV A2 <br />20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FO <br />Ir__ --------------- <br />IDFLWIL <br />r_______- <br />SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. <br />II <br />I <br />------------ <br />I I <br />21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR <br />I \ <br />I <br />-------fi <br />SECURITY AND SAFETY. <br />22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM <br />\ <br />i <br />i <br />El <br />I <br />DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. <br />I <br />I <br />I <br />I <br />I <br />BUILDING PLAN LEGEND <br />-n <br />\ � <br />I -' <br />� <br />M EMI R ,�00 M <br />L-------- <br />--------J <br />I I <br />L <br />I <br />I <br />O DOOR SYMBOL <br />A7-10 A7-20 <br />XX WINDOW & STOREFRONT SYMBOL <br />I I <br />I <br />I <br />A7-30 A7-40 <br />/ I <br />I <br />I <br />FD FLOOR DRAIN - SEE PLMB <br />I <br />I <br />I <br />TV <br />FIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, X <br />I <br />I <br />I <br />FEC SEMI -RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH <br />AD XX <br />LOCAL FIRE AUTHORITY. <br />•' : <br />I <br />I <br />I <br />•' <br />I <br />I <br />I <br />I <br />_ <br />DS DOWNSPOUT <br />.r <br />; <br />� DIRECTION OF SLOPE 1/4 / FT U.N.O. <br />IDS <br />\ <br />i <br />I <br />WATERPROOF TRAFFIC COATING X <br />ADXX <br />M <br />\I <br />S R ROOM <br />x <br />•:' <br />— OPEN TO,BELOW <br />: • <br />----------I— CONCRETE TOPPING SLAB <br />/ <br />— — <br />AD-XX <br />(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) <br />\ <br />- <br />LEASING OFFICE <br />ISO I I I � I I I ISO 3-HR RATED FIRE WALL <br />/ <br />/ <br />2-HR RATED FIRE BARRIER <br />1 I <br />I <br />3 <br />\ <br />I <br />O <br />CONCRETE WHEEL STOP <br />AD-31 <br />I <br />O <br />SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. <br />\ / <br />/ YOGA STORAGE <br />4 <br />:: <br />:; , <br />:. <br />SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS <br />-3" Fs j FS =FINISH SURFACE <br />• •. <br />� � <br />�-----------------, <br />----- , � <br />-6" TOC TOC =TOP OF STRUCTURAL CONCRETE SLAB <br />I I <br />i <br />TO CURB =TOP OF CURB <br />a <br />I <br />ACCESSIBLE PARKING SPACE <br />Ii <br />' <br />: ;: <br />I <br />I <br />------ <br />> <br />------ --- ------------- — : ;: <br />CONCRETE STRUCTURAL SLAB TRANSITIONS <br />DEPRESSION LEVEL TO SLOPE <br />� <br />70V <br />GORRI <br />� <br />\ <br />/ <br />I I <br />T1 <br />El <br />= <br />VENTI L <br />I I < <br />SLOPE TO LEVEL X DEPRESSION TO SLOPE <br />L-------------------J <br />SHAFT <br />- -m - <br />--- -J <br />\ <br />T <br />MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM <br />ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR <br />AFF IN ALL OTHER LOCATIONS OF GARAGE. <br />YOGA STUDIO <br />❑❑❑❑❑❑❑❑❑❑ 12 12 <br />❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ DETECTABLE WARNINGS, MIN 36" WIDE <br />10000000000 AD-01 AD-31 <br />// <br />\ <br />I <br />m <br />/ r <br />X <br />WATERPROOF TRAFFIC COATING AD-XX <br />PEl-L <br />/ <br />CONCRETE TOPPING SLAB X <br />\ <br />/ <br />I <br />(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5-0" O.C. U.N.O.) AD XX <br />--------, <br />r ---- <br />CORRIDOR <br />—� <br />— ---- �— / i <br />r <br />/" ----------------- <br />___r_r <br />FRAMED WALL - 3-5/8" METAL STUD <br />\ I I <br />VENTILATION <br />I l <br />-STAIR A3 <br />I I <br />I I <br />I I <br />I <br />FRAMED WALL - 6" METAL STUD <br />SHAFT <br />FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB <br />\ <br />40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVE <br />I <br />_ <br />CMU WALL - SEE STRUCTURAL <br />� <br />I I I I I II I I I <br />\ I I I I I I I I I <br />I <br />I <br />I <br />I <br />I I I I <br />I I I I <br />I <br />I I I l l l l l l l l <br />I I I I <br />X <br />CONCRETE WALL - SEE STRUCTURAL <br />AD-XX <br />I � <br />I I I I I I I II I I I I I I I I II I I I <br />I I II I I I II I <br />I I I I I I I <br />I <br />I <br />" <br />I I I I I <br />I I I I <br />I I I I <br />I I I I I I I I I I I I I I I I <br />I I I I <br />I I I I <br />X <br />------------- AIRCRAFT CABLE VEHICULAR BARRIER <br />------------------------J <br />AD-XX <br />- - - - - - <br />\ <br />\ \ <br />- - - - <br />- - - - - - - - - J / <br />L-------------- - <br />FULL HEIGHT STEEL FENCING AD 31 <br />/ <br />\ \ <br />/ <br />CONCRETE COLUMN X <br />, -COLUMN CAP AD-XX <br />/ I <br />i <br />L J <br />OPEN TO <br />BELOW <br />" <br />KEYNOTES <br />---------------- <br />------- ----------; <br />�I <br />FITNESS <br />I <br />I <br />I <br />LINE OF FLOOR ABOVE <br />/ <br />\ <br />i <br />i <br />I <br />2❑ MECHANICAL SHAFT - SEE MECHANICAL DWGS <br />I <br />I I I • <br />I I <br />I <br />I <br />❑3 RETAIL PARKING SPACE <br />/ <br />\ <br />I <br />I <br />4❑ GUEST PARKING SPACE <br />EV READY SPACE (FUTURE) <br />________ ______ <br />� _� <br />L-----------------J � L_______________ ----------------- <br />i <br />❑6 EV CHARGING SPACE (INSTALLED), REFER TO DETAIL 9/AD-31 <br />/ <br />�--------- <br />I <br />❑7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 <br />I <br />❑8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 <br />�9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 <br />� <br />I <br />IE �p <br />10 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 <br />---- -- ----� <br />r---------------� <br />r <br />A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR <br />B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR <br />I <br />/ /-----------J <br />I I <br />I <br />I <br />11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 <br />-1 <br />12 EXPANSION JOINT, REFER TO SHEET AD-33 <br />E <br />IVF-1 <br />--J <br />STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION <br />------------ <br />---------------- <br />13 <br />WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF <br />CONCRETE SLAB ABOVE. <br />I I I <br />DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB <br />LEASING AND AMENITY - LEVEL 2 REFLECTED CEILING PLAN <br />SCALE:3/16"=1'-0 <br />2 <br />LEASING AND AMENITY - LEVEL 1 REFLECTED CEILING PLAN <br />SCALE:3/16"=l'-0 <br />1 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVIDS'FINAENTS <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />i <br />O <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />Z <br />Q <br />U) <br />W <br />U) <br />F_ <br />ICT <br />LO <br />T_ <br />L0 <br />015 <br />Nt <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />SED ARC,yl <br />* No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />OF CAS\ <br />License Stamp <br />LEASING & AMENITY <br />ENLARGED <br />REFLECTED CEILING <br />PLAN <br />BUILDING <br />A A5-56 <br />J <br />H <br />m <br />co <br />U <br />W <br />2 <br />U <br />Z <br />Q <br />^J <br />L`L <br />1r n <br />VM! <br />LL <br />(N <br />CN <br />C) <br />N <br />Ir— <br />C) <br />00 <br />COPYRIGHT (C) <br />