My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 4:26:33 PM
Creation date
8/14/2023 7:49:24 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
23
Date
12/6/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEVATORS 131 AND B2 - ROOF I SCALE: 1/4"=V-0" 13 <br />ELEVATORS B1 AND B2 - LEVELS 2, 3, 4 & 5 SCALE: 1/4"=1'-0"1 2 <br />ELEVATOR KEYNOTES <br />1❑ HOIST BEAM - SEE STRUCTURAL FOR ADDITIONAL INFO <br />2� AUTOMATIC HOISTWAY DOOR <br />3 SMOKE CONTAINMENT CURTAIN COMPLYING WTH CBC 3006.3.5: <br />SMOKE CURTAIN BY SMOKEGUARD PER M400. CONCEAL HOUSING IN DROPPED SOFFIT OR <br />FLOOR / CEILING ASSEMBLY. SMOKE CURTAIN IS NOT REQUIRED WHERE LOBBY IS PROVIDED <br />OR AT LEVEL OF DISCHARGE. LINE JOIST BAY WHEN OCCURS IN FLOOR / CEILING ASSEMBLY. <br />REFER TO BUILDING PLANS. PER CBC SEC. 713.14.1 EXP. #3. <br />❑4 METAL SERVICE LADDER BY ELEVATOR MANUFACTURER <br />❑5 HOIST / SAFETY BEAM PER STRUCTURAL <br />El5 x5 x Z" STEEL TUBE DIVIDER BEAM <br />�7 EMERGENCY EVACUATION SIGN <br />8 24" x 84" GURNEY SPACE <br />ELEVATOR NOTES <br />1. FOR TYPICAL ELEVATOR DETAILS AND NOTES, REFER TO AD 04 <br />2. ALL DIMENSIONS ARE TO FACE OF STUD, CMU OR CONCRETE. <br />3. PROVIDE TWO WAY COMMUNICATION SYSTEM PER CBC 1009.8. <br />4. AT ACCESSIBLE MEANS OF EGRESS ELEVATORS, DIRECTIONAL SIGNAGE SHALL BE PROVIDED <br />TO DIRECT USERS TO ACCESSIBLE MEANS OF EGRESS AND WITHIN ACCESSIBLE ELEVATOR <br />LANDINGS PER CBC 1009.10. <br />5. PROVIDED 1-1/2 HOUR RATEED HOISTWAY DOOR, TYP. <br />6. CONFIRM HOISTWAY VENTILATION REQUIREMENTS WITH MANUFACTURER. <br />ELEVATOR DESIGN CRITERIA <br />THE ELEVATOR HOISTWAY HAS BEEN DESIGNED TO FIT THE ELEVATOR DESCRIBED BELOW. ANY <br />OTHER ELEVATOR WILL REQUIRE REVISIONS TO THE DRAWINGS. NOTIFY THE ARCHITECT <br />IMMEDIATELY IF A SUBSTITUTION IS PROPOSED. <br />ELEVATOR Al <br />ELEVATOR A2 <br />ELEVATOR B1 <br />ELEVATOR B2 <br />MODEL <br />OTIS GEN 3 EDGE <br />OTIS GEN 3 EDGE <br />OTIS GEN 3 EDGE <br />OTIS GEN 3 EDGE <br />CAPACITY / SPEED <br />3,500 LBS 1150 FPM <br />2,500 LBS 1150 FPM <br />3,500 LBS 1150 FPM <br />2,500 LBS 1150 FPM <br />POWER <br />STOPS 7 7 5 5 <br />SEISMIC ZONE SEE STRUCTURAL SEE STRUCTURAL SEE STRUCTURAL SEE STRUCTURAL <br />MIN. HOISTWAY 8'-8" x 6-11" 8'-8" x 5'-9" 1T-8" x 6-11" 8'-8" x 5'-9" <br />SIZE <br />PROVIDED SHAFT <br />SIZE <br />OPENING <br />LEFT SIDE <br />LEFT SIDE <br />LEFT SIDE <br />RIGHT SIDE <br />FRONT ONLY <br />FRONT ONLY <br />FRONT ONLY <br />FRONT ONLY <br />CLEARANCE TO <br />X'-X" <br />X'-X" <br />X'-X" <br />X'-X" <br />UNDERSIDE OF <br />(13'-10" CLEAR <br />(13'-10" CLEAR <br />(13'-7" CLEAR <br />(13'-7" CLEAR <br />ROOF FRAMING <br />OVERHEAD TO <br />OVERHEAD TO <br />OVERHEAD TO <br />OVERHEAD TO <br />SAFETY BEAM + 12" <br />SAFETY BEAM + 12" <br />SAFETY BEAM + 12" <br />SAFETY BEAM + 12" <br />SAFETY BEAM +4 <br />SAFETY BEAM + 4 <br />SAFETY BEAM + 4 <br />SAFETY BEAM + 4 <br />3/4" CLEAR ABOVE <br />3/4" CLEAR ABOVE <br />3/4" CLEAR ABOVE <br />3/4" CLEAR ABOVE <br />BEAM +2 LAYERS <br />BEAM + 2 LAYERS <br />BEAM + 2 LAYERS <br />BEAM + 2 LAYERS <br />5/8" GYP BD) <br />5/8" GYP BD) <br />5/8" GYP BD <br />5/8" GYP BD <br />PIT DEPTH <br />5-6" <br />5-6" <br />5-0" <br />5-0" <br />CAB & HOISTWAY <br />4A" x T-0" <br />4A" x T-0" <br />4A" x T-0" <br />4A" x T-0" <br />DOOR <br />90-MIN RATED <br />90-MIN RATED <br />90-MIN RATED <br />90-MIN RATED <br />CAR SIZE, INTERIOR <br />6-5 9116" x 5-5 9/16" <br />6-5 9/16" x 4'-3 9/16" <br />6-5 9/16" x 5-5 9/16" <br />6-5 9116" x 4'-3 9/16" <br />CAR CEILING T.9" T.9" T.9" T.9" <br />CAR CEILING FINISH AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER <br />CAR WALL FINISH AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER <br />CAR FLOOR FINISH AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER AS SELECTED BY OWNER <br />MEDICAL YES - 24"x84" STRECHER NO YES - 24"x84" STRECHER NO <br />EMERGENCY <br />LEGEND <br />2X4 WOOD STUD FRAMING <br />2X6 WOOD STUD FRAMING <br />CMU WALL - SEE STRUCTURAL <br />CONCRETE WALL - SEE STRUCTURAL <br />EXTENT OF EXTERIOR CEMENT PLASTER FINISH <br />DIAGONAL HATCH INDICATES EXTENT OF EXTERIOR PLASTER SOFFIT OR <br />DROPPED GYP. BID. HEIGHT AS INDICATED ILN PLAN EXTERIOR CEM NING BELOW RATED SOILINGT FFIT <br />ER OV RBEXTRUDED <br />METAL LATH OCCURS AT LOBBIES WITH EXTERIOR WALL OPENINGS. SEE <br />ENLARGED PLANS FOR EXTENT. <br />r <br />30" x48" CLEAR FLOOR AREA <br />L J <br />5-0" DIAMETER TURN AROUND SPACE <br />i <br />ENLARGED PLAN REFERENCES <br />1. FOR WALL FIRE -RATINGS AND DETAIL REFERENCES, FIRE EXTINGUISHER <br />LOCATIONS AND FIRE ACCESS ANALYSIS, SEE SHEETS AO-11 THRU AO-25 . <br />2. FOR EXITING ANALYSIS INCLUDING OCCUPANT LOADS, EXIT SIGNS AND DOOR PANIC <br />HARDWARE LOCATIONS, SEE SHEETS AO-31 THRU AO-45. <br />• <br />i <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />EI7 OAK <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />T_ <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />w <br />w <br />U) <br />F_ <br />ICT <br />LO <br />T_ <br />L0 <br />0115 <br />T_ <br />Nt <br />No. Date Description H <br />10 <br />U) <br />U <br />W <br />U <br />Z <br />Q <br />J <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />n <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />jr <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v J <br />S&D ARC,S,,T <br />ILL <br />�0 �� <br />N <br />(N <br />* No. C29795 * <br />C) <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />qTF OF <br />C m_ <br />License Stamp <br />o <br />ELEVATORS B1 & B2 <br />PLANS <br />ELEVATORS 131 AND B2 - LEVEL 1 1 SCALE: 1/4"=V-0" 1 1 <br />COPYRIGHT <br />BUILDING <br />B A5-92 <br />
The URL can be used to link to this page
Your browser does not support the video tag.