Laserfiche WebLink
GSM "L" FLASHING <br />11 <br />DOOR PAN FLASHING <br />CEMCO #7 EXTENDED FOUNDATION <br />GS88 PIGMENTED SEALER <br />n CEMCO # 66 EXPANDED FLANGE <br />SCREED WITH 1-1/2" EXTENSION <br />GSM 1" FLASHING LAPPED OVER CEMCO #7 EXTENDED FOUNDATION <br />SCUPPER <br />GU80 TOPCOAT <br />CASING BEAD. APPLY 0/ W.R.B. <br />CEMCO # 66 EXPANDED FLANGE <br />SCREED WITH 1-1/2" EXTENSION <br />CASING BEAD <br />SCUPPER (DECK SIDE) PARALLEL W/ IMPERVIOUS SURFACE <br />3/4" FIBERGLASS WITH PD RESIN (S <br />CONTINUOUS BEAD OF SEALANT AT <br />COATS) <br />(5)CEMCO #7 EXTENDED FOUNDATION <br />OVERLAP SEAM 3 BEDS OF SEALANT 1" APART <br />PRIMER <br />SCREED WITH 1-1/2" EXTENSIO, <br />INTEGRAL STUCCO SCREED 3 SIDES. <br />EXTEND 1" PAST GSM "L" FLASHING <br />WALL <br />SEE PROFILE SECTION <br />I <br />N <br />SEALANT AT JOINT A <br />GSM 1" FLASHING <br />I <br />8 a° <br />0 w <br />IMPERVIOUS <br />w _J <br />SURFACE STOP, <br />U) <br />U <br />B I <br />HEIGHT TO TOP OF <br />WALL FLASHING °° a <br />o <br />IMPERVIOUS T <br />a <br />3 GSM EDGE FLASHING <br />,\ I <br />Q <br />1 I <br />SURFACE <br />bo <br />° a° a a <br />3 BEDS OF SEALANT 1" APART <br />i �',��, I <br />°4 <br />° ° ° ° <br />�i <br />����; '�I '''''' <br />° <br />20 ° ° a <br />j j 2O <br />`���' , ; ��� ���, � �� III �', <br />I I I I � — <br />- �--► <br />� - <br />�„ <br />�fc� <br />SADDLE FLASHING <br />� <br />SADDLE FLASHING <br />��ONE PIECE SOLDERED SADDLE <br />��� �i <br />v[ FLASHING <br />_, S.A.F. <br />_— <br />15 <br />20 <br />cfl <br />W.R.B. <br />----__-._,,� �PQ <br />POST <br />FLASHING <br />DECK EDGE <br />METAL <br />o <br />CONC. DECK y '� <br />N <br />SURFACE <br />I I I Ic <br />DECKPLAN — SHEET FLOW <br />1 <br />y <br />SEE SCUPPER DETAIL. FOR ADDITIONAL INFORMATION SEE DETAILS <br />1 CONCRETE PATIO EDGE <br />i J <br />I <br />I <br />WALL <br />� I IL SADDLE FLASHING <br />S.A.F. <br />GSM EDGE FLASHING <br />1 <br />8 WALL <br />o <br />FLASHING <br />CONIC. DECK EDGE PERPENDICULAR TO <br />III <br />Z <br />WALL <br />MIN. CON-DEK ASSEMBLY THICKNESS <br />II 1 <br />GSM IT." FLASHING <br />SUBSTRATE <br />SUBSTRATE <br />1 PRE-TREATMENT 0/ BASE COAT 0/ <br />I i <br />SLOB <br />SLOPE <br />CONC. IMPERVIOUS SURFACE <br />i GSM "L" FLASHING 3" MIN. ABOVE <br />DECK PRE-TREATMENT 0/ BASE COAT 0/ <br />/ FOUNDATION SCREED FLASHING <br />SLOPE GSM DECK EDGE METAL <br />I <br />SADDLE FLASHING <br />CONTINUOUS 1/2" BEAD OF SEALANT <br />ALL FOUR SIDES OF GSM "COLLAR" <br />~ 0- <br />3-COAT STUCCO SYSTEM 0/ METAL <br />FLASHING <br />�o <br />Cn <br />SADDLE FLASHING <br />LATH 0/ W.R.B. 0/ S.A.F. 0/ CEMCO #7 <br />I <br />m <br />I <br />WIDTH OF SCUPPER NOT TO EXCEED <br />GSM DECK EDGE METAL <br />_ 4" AT OCCUPIED ROOF <br />$ ° ° <br />° d <br />IMPERVIOUS SURFACE, OVERLAP <br />° I CEMCO # 66 EXPANDED FLANGE <br />°d <br />CONC. LATH ON THE FLASHING TO THE EDGE <br />HEM SIDE AND TOP EDGES OF GSM <br />°°°° ° ° ° CASING BEAD 0/ W.R.B. 0/ SADDLE PATIO OF THE DECK SURFACE <br />"SCUPPER" FLASHING TO ALIGN WITH <br />I <br />FLASHING 0/ S.A.F. <br />N <br />SLOPE <br />3/4EXTERIOR FINISH. <br />° <br />° ° 3-COAT STUCCO SYSTEM 0/ METAL <br />° ° <br />°° CEMCO #7 EXTENDED FOUNDATION <br />° d° ° ° ° d° ° ° <br />° ° LATH 0/ W.R.B. <br />° SCREED WITH 1-1/2" EXTENSION <br />° ° ° <br />4" ° ° EXTEND BOTTOM LOCK HOOK SEAM <br />a ° 2" ° ° <br />PARALLEL W/ IMPERVIOUS SURFACE <br />° ° <br />a ° ° OF SCUPPER 3/4" BEYOND "COLLAR" <br />° d ° a° ° ° 'i( W.R.B. 0/ S.A.F. 0/ SOFFIT DRIP <br />°° <br />° ° ° ° ° <br />° <br />° ° °° ° I FLASHING TO ACCOMMODATE <br />° <br />12 <br />16 <br />EDGE <br />° o ° <br />d ° ° I CONDUCTOR HEAD CONNECTION <br />WALL FLASHING <br />DECK DRAIN <br />FACE OF EXTERIOR FINISH <br />° ° d <br />°° d ° <br />° Al° <br />° APPLY SEALANT AFTER COMPLETION <br />° g d ° <br />° <br />° <br />CEMCO # 12 SOFFIT DRIP EDGE, <br />d ° <br />a ° ° ° ° ° ° OF IMPERVIOUS SURFACE SYSTEM <br />° ° ° ° o ° ° ° ° ° ° <br />° <br />EXTEND 1"PAST OPENING WHEN <br />° d ° °J FINISH COAT <br />a °° ° d , ° ° ° <br />° ° <br />DECK EDGE IS FLUSH WITH WALL <br />NOTES: IMPERVIOUS SURFACE TO REMAIN A MINIMUM OF 2" BELOW THE PERIMETER WEEP SCREED. <br />BEYOND <br />ROOF DECK DRAINAGE, INCLUDING SECONDARY DRAINS, SHALL COMPLY WITH CBC SECTION 1503 <br />AND THE CALIFORNIA PLUMBING CODE. <br />SECTION A <br />SECTION B <br />4 <br />FOR ADDITIONAL INFO. ON SECTION A SEE DETAIL 10 FOR ADDITIONAL INFO. ON SECTION B <br />SEE DETAIL 8 FOR ADDITIONAL REQUIREMENTS AND INFO. SEE DETAIL 2 <br />SECTION A: SCUPPER DRAIN <br />FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILS <br />GSM SCUPPER <br />10 <br />PATIO PLAN -LOW WALL WITH DRAIN <br />2 <br />sG6's <br />BUILD UP BASE COAT CRICKET WITH <br />SADDLE FLASHING <br />o� 9� <br />F` F` <br />1/4" RISE ON UP SLOPE SIDE <br />GS88 PIGMENTED SEALER <br />6 CEMCO # 66 EXPANDED FLANGE <br />WALL <br />2 PIECE "C" SHAPED GSM "L" <br />IN <br />WALL ASSEMBLY BEYOND <br />P <br />GU80 TOPCOAT <br />CASING BEAD, APPLY 0/ W.R.B. <br />THE DIRECTION OF SLOPE <br />INTERIOR <br />INTERIOR FINISH FLOOR <br /><)� � I <br />GSM 1" FLASHING <br />owe <br />�`����' <br />"C" SHAPE SHALL BE PRE -MADE AND <br />SOLDERED <br />DOOR AND THRESHOLD ASSEMBLY <br />�(JI� <br />� <br />3/4" FIBERGLASS WITH PD RESIN (S <br />COATS) <br />� <br />NOTE: <br />PER DOOR SCHEDULE <br />PRIMER <br />L CEMCO #7 EXTENDED FOUNDATION <br />8 <br />FLASHING SEAMS AND LAPS SHALL BE INSTALLED AS TO NOT BUCK WATER, SEE DETAIL <br />SCREED WITH 1-1/2" EXTENSION <br />"WALL FLASHING" FOR TYPICAL REQUIREMENTS AT LAP. <br />APPLY JOINT SEALANT AFTER <br />COMPLETION OF IMPERVIOUS <br />a ° <br />5 CEMCO #7 EXTENDED FOUNDATION <br />SURFACE SYSTEM FINISH COAT AND <br />a <br />SCREED WITH 1-1/2" EXTENSION, <br />"L" <br />i <br />POST <br />3-COAT STUCCO SYSTEM 0/ METAL <br />PRIOR TO DOOR THRESHOLD <br />a <br />EXTEND 1" PAST GSM FLASHING <br />i <br />(PER PLAN) �� <br />LATH 0/ W.R.B. <br />INSTALLATION <br />° ° <br />4 GSM "L" FLASHING <br />i / <br />GSM "L" <br />FLASHING <br />W.R.B. 0/ S.A.F. 0/ FOUNDATION <br />SCREED FLASHING <br />PRE-TREATMENT 0/ BASE COAT 0/ <br />nd ° A <br />1 <br />GSM 1 PIECE DOOR FLASHING PAN <br />° ° <br />3 PRE -MADE CORNER GSM EDGE <br />FLASHING <br />� � � � <br />�� '� <br />� I I � <br />CEMCO #7 EXTENDED FOUNDATION <br />SCREED WITH 1-1/2" EXTENSION <br />X 3 <br />� � ��e- � <br />o <br />� S��Q� <br />a ° a a ° A ° <br />SEALANT OOZE OUT <br />Q GSM 1 PIECE DOOR <br />TO AND <br />it <br />PARALLEL W/ IMPERVIOUS SURFACE <br />FLASHING PAN AD 52 <br />a <br />i9 3 BED F SEALANT 1" APART T <br />, � BUTTERED AT JOINT <br />_ <br />� c0 it � <br />APPLY JOINT SEALANT AFTER <br />� SUBSTRATE <br />/ <br />1`/ <br />°° G ° 4 <br />RECEIVE 1" FLASHING <br />¢" <br />i <br />PRE -MADE CORNER GSM EDGE <br />i <br />COMPLETION OF IMPERVIOUS <br />SURFACE SYSTEM FINISH COAT <br />SLOPE <br />i FLASHING <br />° ° ° <br />CONCRETE DECK SLOPED TO DRAIN <br />/ <br />\ oo`�� <br />N <br />N <br />IMPERVIOUS SURFACE <br />�o <br />� 2 ONE PIECE SOLDERED SADDLE <br />FLASHING <br />� CONC. DECK <br />� � � <br />/ SURFACE ��oQ <br />o o <br />PRE-TREATMENT 0/ BASE COAT 0/ <br />GSM 1" FLASHING <br />° ° <br />IT." <br />4" MINIMUM IMPERVIOUS SURFACE <br />LAPPED GSM FLASHING <br />3 BEDS OF SEALANT 1"APART TO <br />\ <br />POST BASE PER °° ° , °°d ° d°°4.1 <br />3 BEDS OF SEALANT I" APART <br />wAL OVA RECEIVE CORNER DECK EDGE <br />�� <br />STRUCTURAL, GSM L ° <br />CONTINUOUS BEAD OF SEALANT AT <br />vo��' <br />o�oQ <br />LIE <br />OVERLAP SEAM <br />VE RTHCALLYHFLAT <br />AGAINST THE POST AND <br />WALL EDGE LAP GSM "L" FLASHING <br />NOTE: REFERENCE CON-DEK SPECIFICATIONS FOR PROPER LATH INSTALLATION. <br />1 CONCRETE DECK SURFACE <br />\ <br />\���\ <br />POST BASE <br />FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAIL <br />2 <br />FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAIL 2 <br />NOTE: ALL FLASHING SEAMS AND LAPS SHALL BE INSTALLED AS TO NOT BUCK WATER. <br />FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILS 1 2 <br />CONCRETE DECK EDGE PROTRUDING BEYOND <br />2X6FRAMING <br />POST FLASHING <br />15 <br />DOOR PAN FLASHING <br />11 <br />CON-DEK SYSTEM <br />3 <br />EXTERIOR WALL <br />W.R.B. <br />TWO-PLY "WEATHER TEX" BY FORTIFIBER BUILDING SYSTEMS GROUP OR APPROVED EQUAL. <br />EXT. CEM. PLAS OVER <br />WEATHER RESISTIVE BARRIER (W.R.B.), SUPER JUMBO TEX 60 MINUTE BUILDING PAPER OVER <br />6 CEMCO # 66 EXPANDED FLANGE <br />5/8" TYPE "X" GYP BD 0/ <br />WEATHERSMART HOUSE WRAP. <br />CASING BEAD, APPLY 0/ W.R.B. <br />PLYWD SHTG WHERE OCCURS <br />SEE - SEE STRUCTURAL <br />S.A.F. <br />FORTIFIBER FORTIFLASH OR APPROVED EQUAL. SELF ADHESIVE, HEALING FLASHING (S.A.F.) <br />12" WIDE (U.N.O.) 25 MIL (U.N.O.), 25 MIL (U.N.O.) ADHERE S.A.F. TO CLEAN, DUST FREE BACKING <br />BONDERIZED 26 GA GALV. <br />AND USE CHEMICALLY COMPATIBLE PRIMERS & W.R.B. WITH ADHESIVE SIDE. <br />5 CEMCO #7 EXTENDED FOUNDATION <br />SCREED WITH 1 1/2" EXTENSION, <br />PL <br />WALL GSM IT." FLASHING <br />"L" FLASHING ATTACHED WITH <br />FASTENERS AS RECOMM. BY <br />GSM FLASHING STUCCO ACCESSORIES SHALL BE CEMCO "WATER MANAGEMENT SERIES", 25 GA. MATERIAL <br />EXTEND 1" PAST GSM 1" FLASHING <br />CON-DEK MANUF. <br />WITH A G-90 GALVANIZED COATING OR ARCHITECT APPROVED EQUAL. GSM FLASHING METAL <br />SHALL BE SHOP FABRICATED USING A MINIMUM 26 GA. G-90 GALVANIZED SHEET METAL WITH <br />SADDLE FLASHING <br />CEMCO #7 WEEP SCREED WITH <br />SOLDERED JOINTS (U.N.O.), UNLESS NOTED OTHERWISE. <br />REMOVABLE DRAIN CAP <br />BOND BREAKER TAPE <br />STAPLES <br />CORROSION-RESISTANT STAPLES. FASTEN LATH TO EXTERIOR GRADE PLYWOOD. <br />4 GSM "L" FLASHING <br />CEMCO #7 EXTENDED FOUNDATION <br />SCREED WITH 1-1/2" EXTENSION <br />-CON-DEK SYSTEM <br />ASTM C-920 <br />POLYURETHANE JOINT <br />��r <br />������ <br />SEALANT AFTER COMPLETION <br />IMPERVIOUS SURFACE <br />ICC -ESR 2097 REPORT PLI-DEK "F" SYSTEM =PLI-DEK 1-HOUR 1 CLASS "A" FIRE RATED <br />OF CON-DEK FINISH COAT <br />IMPERVIOUS SURFACE, FIBERGLASS AND RESIN REINFORCED WATERPROOF DECK COATING <br />WITH KNOCKDOWN TEXTURE APPLIED AS PER MFG SPECIFICATIONS. COLOR TBD. <br />3PRE-MADE CORNER GSM EDGE <br />i GSM EDGE FLASHING <br />_ _ _ _ _ —, <br />— — — — — 4 — <br />CON-DEK SYSTEM <br />C° SUBSTRATE <br />WWW.PLIDEK.COM 800-364-0287 <br />FLASHING <br />° <br />GAUGE STAINLESS <br />- TO DRAIN CON-DEK SYSTEM BY PLI-DECK <br />LATH <br />2.5 LBS / SQ.YD. GALVANIZED (DIPPED) EXPANDED METAL 96" X 27" <br />d m ° <br />STRAINER (BY OTHERS) <br />IN SYSTEM OVER CONCRETE <br />4 <br />CONCRETE DECK oo� <br />SURFACE e`�- <br />d <br />d ° ° ° ° ° ° ° d <br />° <br />° ° d <br />TRUCT. CONIC. SLAB <br />EXT. GRADE PLYWOOD MINIMUM 3/4" EXTERIOR GRADE T&G, BLOCK ALL UNSUPPORTED JOINTS AND FASTEN WITH <br />SCREWS AT DECKS. SEE STRUCTURAL DOCUMENTS FOR ADDITIONAL INFORMATION. COVER <br />3 BEDS OF SEALANT 1"APART <br />�o <br />da <br />d° ° ° <br />d <br />ALL JOINTS WITH PLI DEK SEAM PAPER. FOR RATED ASSEMBLY CONSTRUCTION, SEE ICC ESR <br />d <br />^ -° ° <br />2097 REPORT, SECTION 4.4.1. <br />s<" <br />° ° ° ° °� E21 ° 2' MIN. ° ° <br />° <br />PRE-TREATMENT ALL DECK TO WALUTHRESHOLD TRANSITIONS TO BE PRE-TREATED WITH PD RESIN AND <br />o <br />°d <br />REINFORCEMENT FABRIC PRIOR TO EXTENDED FOUNDATION SCREED INSTALLATION AND <br />° <br />d ° °° <br />AFTER BASE COAT INSTALLATION. GU80 TOP COAT AND GS88 PIGMENTED SEALER TO BE <br />° ° <br />INSTALLED VERTICALLY IN CONJUNCTION WITH DECK SYSTEM FINISH COATS. <br />PLAN REFERENCE <br />--2)ONE PIECE SOLDERED SADDLE <br />���\ <br />° ° ° ° ° ° °° ° ° ° ° <br />SUBSTRATE <br />1/4" = V-0", SLOPE MUST BE BUILT INTO FRAMED SUBSTRATE. <br />FLASHING <br />°° <br />° STRUCTURALSLAB-SEE <br />SLOP <br />CONCRETE DECK EDGE FLUSH WI <br />s ° ° ° ° STRUCTURAL DRWG <br />co�� <br />° ° <br />BOND BREAKER <br />POLYETHYLENE TAPE TO BE USED AS BOND BREAKER, REQUIRED BETWEEN ACRYLIC <br />WALL V�PLL o oQ� <br />EXTE R I 0 R WALL <br />RUN <br />FROM THE SOLID PLASTER AND INT FINISHES AND VERTICAL LEG TOALL 1/8" FROMNG FRONT SOLID DGE. ANY APPLIEDAPE FIN SHOE THAT <br />DRAIN MANUFACTURER - THUNDERBIRD PRODUCTS, 800-658-2743, THUNDERBIRDPRODUCTS.COM <br />CREATES A BOND BETWEEN THE PLASTER AND METAL SHALL BE BROKEN WITH UTILITY KNIFE <br />AND SHALL BE MAINTAINED AS SUCH. <br />__ __CONCRETE DECK SURFACE <br />f <br />SHOWN IN DETAIL 1 <br />2 4 <br />SEALANT <br />NP1 SONOLASTIC POLYURETHANE SEALANT OR APPROVED EQUAL. EXPOSED SEALANT SHALL <br />(NOT ) <br />FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILS <br />® <br />BE CHECKED ANNUALLY AND MAINTAINED PER MANUFACTURERS RECOMMENDATION TO <br />MAINTAIN A WATER TIGHT SEAL. <br />SADDLE FLASHING ASSEMBLY (WALL FLASHING TO DECK EDGE METAL) <br />20 <br />PATIO DRAIN <br />16 <br />PATIO AT CMU PLANTER WALL <br />12 <br />PATIO TO WALL FLASHING <br />8 <br />NOTES <br />4 <br />0 <br />�i <br />Architecture +Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />RED OAK <br />INVESTMENTS <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />No. <br />Ir— <br />O <br />V, u <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />w <br />w <br />U) <br />w <br />T_ <br />LO <br />06 <br />LO <br />T_ <br />It <br />Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />SED ARt, <br />�G R � �L�A <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />s�9TF <br />�F C A\-� <br />License Stamp <br />EXTERIOR <br />IMPERVIOUS <br />SURFACE (CON-DEK) <br />AD-41 01 <br />W <br />MG <br />W <br />�ZD <br />v J <br />U <br />W <br />2 <br />U <br />04 <br />N <br />N <br />1 <br />mu <br />COPYRIGHT U <br />