Laserfiche WebLink
STEP 1O "L" METAL - INSTALL AT DECK TO WALL TRANSITION, PROVIDE SOLID BACKING AT VERTICAL LEGS <br />5/8" GYPSUM WALLBOARD FINISH <br />AND INSTALL WITH A MINIMUM 4" LAP BETWEEN PIECES. <br />T71 <br />I <br />I <br />CORNER FLASH (BEYOND) <br />STEP02 FLASHING PAN - INSTALL ALONG BOTTOM OF OPENING, SET IN SEALANT AND FASTEN THROUGH <br />2-HR RATED WALL PER PLAN <br />— 5/8" GYPSUM WALLBOARD FINISH <br />5/8" GYPSUM WALLBOARD FINISH <br />THE VERTICAL LEGS ONLY TO THE ROUGH FRAMING JAMBS. <br />1-HR RATED WALL PER PLAN <br />FACTORY FINISHED WINDOW <br />STEP PLACE DOOR - PLACE THE DOOR IN THE ROUGH OPENING. PLUMB, SQUARE, AND SHIM THE DOOR, <br />FRAMING PER STRUCTURAL <br />FRAMING PER STRUCTURAL <br />SET IN CONTINUOUS SEALANT <br />THEN FASTEN THE DOOR FRAME TO THE JAMB STUDS. <br />FRAMING PER STRUCTURAL <br />FRAMING PER STRUCTURAL <br />___________ _ _____ <br />APPLY LOW EXPANSION FOAM <br />STEP@ JAMB S.A.F. ATTACH A STRIP OF S.A.F. ALONG EACH SIDE OF JAMB, ADHERING TO THE ROUGH <br />SHEATHING MAY OCCUR <br />SHEATHING MAY OCCUR <br />SHEATHING MAY OCCUR <br />ALL FOUR SIDES OF WINDOW <br />FRAMING AND DOOR JAMB. ALIGN EDGE OF S.A.F. TO INSIDE OF DOOR FRAME JAMB .THE S.A.F. <br />SHEATHING MAY OCCUR <br />I <br />W.R.B. 0/ BUTTERED SEALANT 0/ <br />SHALL OVERLAP THE "L" METAL AND PAN FLASHING AND EXTEND 12" ABOVE THE HEAD ROUGH <br />2x SOLID BACKING REQUIRED AT <br />Q <br />I <br />/ <br />I <br />NAILING FLANGE 0/ WINDOW SETTING <br />OPENING. PRIME SUBSTRATE AS REQUIRED BY S.A.F. MANUF. <br />S.A.F. WHEN SHEATHING NOT <br />2x SOLID BACKING REQUIRED AT <br />/ <br />I <br />I 2x SOLID BACKING REQUIRED <br />1 <br />1 <br />2x SOLID BACKING REQUIRED <br />— SEALANT 0/ SILL PAN S.A.F. 0/ CORNER <br />-------- --- --- <br />STEP 5 HEAD S.A.F. -ADHERE S.A.F. ABOVE THE ROUGH OPENING. EXTEND THE S.A.F. 13" PAST THE ROUGH <br />PROVIDED <br />S.A.F. WHEN SHEATHING NOT <br />I AT S.A.F. WHEN SHEATHING <br />I1 <br />AT S.A.F. WHEN SHEATHING <br />FLASHING 0/ DOOR HEAD S.A.F. <br />OPENING AT EACH END. ALIGN THE BOTTOM EDGE OF THE S.A.F. WITH THE BOTTOM OF THE DOOR <br />PROVIDED <br />I NOT PROVIDED <br />I <br />I i <br />NOT PROVIDED <br />S� <br />FRAME HEAD. <br />I i 3-COAT STUCCO SYSTEM 0/ METAL <br />LATH 0/ W.R.B. 0/ 5/8" TYPE "X" DENS <br />/ <br />Ili <br />3 COAT STUCCO SYSTEM 0/ METAL <br />I 3-COAT STUCCO SYSTEM <br />/ <br />I <br />3-COAT STUCCO SYSTEM <br />Ii <br />� <br />i s: 7 3-COAT STUCCO SYSTEM 0/ METAL <br />3 12 <br />LATH 0/ W.R.B. <br />STEP 5A PLASTER MOULD. - APPLY PLASTER MOULD TO DOOR FRAME ON CONTINUOUS SEALANT. PLASTER <br />GLASS GOLD EXTERIOR SHEATHING <br />LATH 0/ W.R.B. <br />0/ METAL LATH 0/ W.R.B. <br />(1 <br />0/ METAL LATH 0/ W.R.B. <br />( <br />MOULD SHALL ALIGN WITH INSIDE EDGE OF DOOR FRAME. PLASTER MOULD SHALL BE BACK PRIMED. <br />/ I <br />/ I <br />S( <br />7 W.R.B. 0/ 9" WIDE WEEP S.A.F. 0/ <br />III <br />I <br />HEADER PER STRUCTURAL <br />I I � � APPLIED FOAM TRIM; SEE <br />STEP 6A CEMCO #3 - INSTALL FLASHING SCREED AS REQUIRED BY DETAIL. EXTEND THE SCREED 2" PAST <br />HEADER PER STRUCTURAL <br />/ I <br />/ <br />HEADER PER STRUCTURAL <br />I1 2 <br />CEMCO #12 SOFFIT DRIP 0/ W.R.B. <br />I I I <br />I <br />EXTERIOR ELEVATIONS <br />THE ROUGH OPENING AT BOTH ENDS. SET SCREED ONTO HEAD PLASTER MOULD WITH SEALANT. <br />I <br />I <br />W.R.B. 0/ 9"WIDE WEEP S.A.F. <br />I I <br />NOT REQUIRED IF THE DOOR IS PROTECTED BYA MINIMUM 30" DEEP EAVE OR SOFFIT THAT IS <br />I W.R.B. 0/ S.A.F. 0/ #6 HEAD DRIP <br />l <br />i <br />W.R.B. 0/ S.A.F. 0/ #6 HEAD DRIP <br />III CEMCO #12 SOFFIT DRIP; EXTEND <br />I I <br />0/ CEMCO #3 FLASHING SCREED <br />I <br />W.R.B. 0/ SILL PAN S.A.F. (WEEP S.A.F.) <br />I 0/ CEMCO #3 FLASHING SCREED 0/ <br />J <br />WITHIN 24" OF THE DOOR HEAD, THE EAVE OR SOFFIT SHALL EXTEND 30" EACH SIDE OF DOOR. <br />Ij S( <br />APPLIED FOAM TRIM MAY OCCUR, <br />III SL <br />\� <br />� 2" PAST OPENING <br />I � S� <br />0/ DOOR HEAD S.A.F. <br />— <br />DOOR HEAD S.A.F. <br />Z <br />STEP 6B WEEP S.A.F. -ADHERE 9"WIDE S.A.F. OVER CEMCO #3 FLASHING SCREED. EXTEND THE S.A.F. 2" <br />12 <br />1 SEE EXTERIOR ELEVATIONS <br />12 <br />1 <br />APPLIED FOAM TRIM MAY OCCUR, <br />Z <br />— SEE EXTERIOR ELEVATIONS <br />I 1 3; <br />APPLIED FOAM TRIM; SEE <br />_ _ _ — <br />�— g <br />CEMCO #3 FLASHING SCREED, WHEN <br />PAST THE CEMCO #3 FLASHING SCREED AT BOTH ENDS; S.A.F. REQUIRED WITH CEMCO #3. <br />STEPO7 W.R.B. APPLY W.R.B. IN WEATHERBOARD FASHION AROUND THE INSTALLED DOOR. <br />I <br />CEMCO #6 HEAD DRIP <br />I <br />CEMCO #6 HEAD DRIP, EXTEND 1" <br />PAST EACH SIDE OF DOOR FRAME <br />r---J <br />I <br />— J � � <br />I i <br />EXTERIOR ELEVATIONS <br />� / � <br />REQUIRED BY DETAIL 3 THIS SHEET. <br />- <br />66 WEEP S.A.F. ADHERE 0/ CEMCO #3 <br />BOND BREAKERSTEP <br />SET IN SEALANT OVER PLASTER MOULD <br />II <br />I BACKER ROD & SEALANT <br />II <br />— <br />I <br />APPLIED FOAM TRIM MAY OCCUR, <br />— <br />I I <br />W.R.B. 0/ HEAD S.A.F <br />I <br />I <br />CEMCO #3 FLASHING SCREED, WHEN <br />LOW EXPANSION FOAM <br />FLASHING SCREED. <br />STEP@ CEMCO #3 -SET FLASHING SCREED IN <br />II <br />II - <br />SEE EXTERIOR ELEVATIONS <br />_ <br />I <br />� z <br />REQUIRED BY DETAIL 3 THIS SHEET. <br />APPLY WITHIN SHIM CAVITY <br />SEALANT TO PLASTER MOULD HEAD. <br />LOW EXPANSION FOAM <br />I <br />g <br />SET IN SEALANT OVER PLASTER MOULD <br />STEP(@ PLASTER MOULD - APPLY PLASTER <br />APPLY WITHIN SHIM CAVITY <br />PLASTER MOULD 0/ SEALANT 0/ <br />MOULD TO DOOR FRAME ON <br />1 � <br />— — <br />— <br />PLASTER MOULD 0/ SEALANT 0/ S.A.F. <br />S.A.F. 0/ DOOR HEAD W/ BEAD OF <br />SEALANT AT HEAD AND MOULD <br />�� R� CONTINUOUS SEALANT. <br />1 2" 1"01 <br />1 2" <br />BACKER ROD &SEALANT <br />PLASTER MOULD 0/ SEALANT 0/ <br />S.A.F. 0/ DOOR HEAD W/ BEAD OF <br />0/ DOOR FRAME HEAD <br />� G STEP 5 HEAD S.A.F. <br />HOLLOW METAL DOOR FRAME <br />PER DOOR SCHEDULE <br />HOLLOW METAL DOOR FRAME <br />SEALANT AT HEAD AND MOULD <br />VERIFY FRAME <br />DOOR AND FRAME PER DOOR <br />O <br />DOOR SHIM <br />WIDTH WITH <br />SCHEDULE <br />"PEMKO" <br />PER DOOR SCHEDULE <br />"PEMKO" <br />DOOR AND FRAME PER DOOR <br />SCHEDULE <br />DOOR AND FRAME PER DOOR <br />HEAD <br />WALL REQ'MT. <br />I TN p <br />DOOR SEAL S88D <br />DOOR SEAL S88D <br />SCHEDULE <br />.:. <br />OR APPROVED EQUAL <br />OR APPROVED EQUAL <br />FOR ADDITIONAL <br />INFORMATION SEE <br />DETAILS <br />DOOR PER SCHEDULE <br />VERIFY FRAME <br />HEAD WIDTH WITH <br />VERIFY FRAME <br />HEAD WIDTH WITH <br />DOOR PER SCHEDULE <br />VERIFY FRAME <br />HEAD WIDTH WITH <br />HEAD <br />VERIFY FRAME <br />WIDTH WITH <br />� G '\ <br />r p NIN wl �� <br />I �w <br />TRANSOM WINDOW - DOOR <br />5 <br />WALL REQ'MT. <br />WALL REQ'MT. <br />WALL REQ'MT. <br />WALL REQ'MT. <br />I° <br />41, <br />FACTORY FINISHED WINDOW SET IN <br />2-HR RATED WALL PER PLAN <br />1-HR RATED WALL PER PLAN <br />5/8" GYPSUM WALLBOARD FINISH <br />N, S <br />FRAMING PER STRUCTURAL <br />5/8" GYPSUM WALLBOARD FINISH <br />CONTINUOUS SEALANT <br />FRAMING PER STRUCTURAL <br />FRAMING PER STRUCTURAL <br />\ I \ Iv <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />FRAMING PER STRUCTURAL <br />APPLY LOW EXPANSION FOAM ALL <br />\ <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />WHEN SHEATHING NOT PROVIDED <br />FOUR FWINDOW\ <br />OU SIDES S 0 <br />WHEN SHEATHING NOT PROVIDED <br />WHEN SHEATHING NOT PROVIDED <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />SHEATHING MAY OCCUR <br />WHEN SHEATHING NOT PROVIDED <br />5/8" GYPSUM WALLBOARD FINISH <br />SHEATHING MAY OCCUR <br />1/2" <br />1/2" <br />HOLLOW METAL DOOR FRAME <br />SHEATHING MAY OCCUR <br />SHEATHING MAY OCCUR <br />SHEATHING MAY OCCUR <br />IN HOLLOW METAL DOOR FRAME <br />IN <br />PER DOOR SCHEDULE <br />4 1/2" MINIMUM DOOR AND FRAME PER DOOR <br />DOOR SHIM <br />DOOR AND FRAME PER DOOR <br />PER DOOR SCHEDULE <br />SCHEDULE <br />DOOR AND FRAME PER DOOR <br />SCHEDULE <br />oGoy <br />SCHEDULE <br />I <br />I <br />T <br />—_ — — <br />—_ — — I <br />—_ — — <br />_— <br />_ <br />STEPO3 PLACE DOOR <br />— — — — — — — — — J <br />— — <br />— — <br />_ <br />- --- -- -- ----- -- <br />— — <br />SECTION AA STEP0JAMB S.A.F <br />F <br />/ I <br />_ - — — — — <br />_ DOOR SEAL "PEMKO" S88D OR <br />— <br />— — <br />DOOR SEAL "PEMKO" S88D OR <br />APPROVED EQUAL <br />--- --- — --- J� <br />— <br />— <br />— <br />FOR ADDITIONAL <br />PLASTER MOULD 0/ SEALANT 0/ <br />S.A.F. 0/ DOOR JAMB W/ BEAD OF <br />— SEALANT AT JAMB AND MOULD <br />� <br />I ,I — — — — — — — — — — <br />OUGH OPEN IN WIDTH PLUS 26'f <br />APPROVED EQUAL <br />1/2 " <br />WRAP S.A.F. INTO JAMB AND DOWN 0/ <br />L <br />PLASTER MOULD 0/ SEALANT 0/ <br />S.A.F. 0/ DOOR JAMB W/ BEAD OF <br />1/4" <br />PLASTER MOULD 0/ SEALANT 0/ S.A.F. <br />0/ DOOR FRAME JAMB <br />INSTALLATION <br />INFORMATION <br />LOW EXPANSION FOAM <br />- <br />CN <br />APPLY WITHIN SHIM CAVITY <br />WRAP S.A.F. INTO JAMB AND DOWN 0/ <br />"L" <br />DOOR FLASHING PAN AND "L" METAL <br />SEALANT AT JAMB AND MOULD <br />AT WINDOW SEE <br />DOOR FLASHING PAN AND METAL <br />BACKER ROD & SEALANT <br />BACKER ROD & SEALANT <br />LOW EXPANSION FOAM <br />APPLY WITHIN SHIM CAVITY <br />DETAIL <br />1 <br />JAMB S.A.F. DOWN 0/ DOOR <br />FLASHING PAN AND "L" METAL <br />— — — — H <br />__ ---------- -------------- <br />I <br />W.R.B. 0/ CEMCO 4" J-SERIES <br />AD 53 <br />3-COAT STUCCO SYSTEM 0/ <br />W.R.B. O/ CEMCO 4" J SERIES <br />CASING BEAD 0/ S.A.F. CASING BEAD <br />JAMB S.A.F. DOWN 0/ DOOR <br />JAMB S.A.F. DOWN 0/ DOOR <br />METAL LATH 0/ W.R.B. <br />I 10 / <br />CASING BEAD 0/ S.A.F. <br />TO EXTEND UP TO DOOR HEAD <br />FLASHING PAN AND "L" METAL <br />FLASHING PAN AND "L" METAL <br />I ;', STEP05 <br />APPLIED FOAM TRIM MAY OCCUR, <br />APPLIED FOAM TRIM MAY OCCUR, <br />APPLIED FOAM TRIM MAY OCCUR, <br />APPLIED FOAM TRIM MAY OCCUR, <br />APPLIED FOAM TRIM MAY OCCUR, <br />SEE EXTERIOR ELEVATIONS <br />! HEAD S.A.F. <br />I ADHERED <br />SEE EXTERIOR ELEVATIONS <br />SEE EXTERIOR ELEVATIONS <br />SEE EXTERIOR ELEVATIONS <br />SEE EXTERIOR ELEVATIONS <br />JAMB <br />STUCCO SYSTEM 0/ <br />JAMB <br />JAMB <br />STUCCO SYSTEM 0/ <br />JAMB <br />3-COAT STUCCO SYSTEM 0/ <br />JAMB <br />W.R.B. 0/ BUTTERED SEALANT 0/ <br />I STEP@ <br />3-COAT METAL <br />"X" <br />3-COAT STUCCO SYSTEM 0/ METAL <br />3-COAT <br />NAILING FLANGE 0/ WINDOW <br />I JAMB S.A.F. <br />LATH 0/ W.R.B. 0/ 5/8" TYPE DENS <br />4 <br />FOR ADDITIONAL INFORMATION SEE DETAILS GLASS GOLD EXTERIOR SHEATHING <br />4 <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />LATH 0/ W.R.B. <br />OETAL LATH 0/ W.R.B. <br />3 sim <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />METAL LATH 0/ W.R.B. <br />FOR ADDITIONAL INFORMATION SEE <br />SETTING SEALANT 0/JAMB S.A.F. <br />DETAILS <br />ROUGH PEN I ING WIDTH' <br />EXTERIOR DOOR <br />221-HR <br />EXTERIOR DOOR <br />18RECESSED <br />DOOR <br />14 <br />DOOR <br />10 <br />MULLION DOOR -WIND W <br />6 <br />102-HR <br />OUTSWING DOOR <br />DOOR <br />DOOR <br />I <br />S P3 <br />II �P ACE DO R <br />DOOR FRAME WITH INTEGRAL STOP <br />DOOR FRAME WITH INTEGRAL STOP <br />DOOR FRAME WITH INTEGRAL STOP <br />III <br />FACE OF WALL BEYOND <br />FACE OF WALL BEYOND <br />FACE OF WALL BEYOND <br />STEP02 <br />INTERIOR FINISH FLOOR <br />INTERIOR FINISH FLOOR <br />INTERIOR FINISH FLOOR <br />I <br />!', FLASHING PAN <br />FLOORING UP TO 1/4' THICK <br />i <br />�TTACH FLASHING PAf� <br />THRESHOLD STOP, "PEMKO" 1842DS <br />DOOR BOTTOM "PEMKO" 345D OR <br />DOOR BOTTOM "PEMKO' 345D OR <br />I <br />AT VERTICAL SIDES ONL �k <br />4" <br />OR APPROVED EQUAL SET IN <br />APPROVED EQUAL <br />APPROVED EQUAL <br />LAP <br />CONTINUOUS BEAD OR SEALANT <br />I <br />TYP <br />* <br />F. F. I <br />J_ <br />----------- <br />--------------------- <br />W <br />N <br />— <br />W <br />CO <br />co <br />DOOR BOTTOM "PEMKO" 3452DV OR <br />n <br />Ol­- 00 <br />� <br />APPROVED EQUAL, SEAL TO DOOR <br />1111� <br />00 2 <br />O <br />> <br />X o m <br />Q Q <br />"PEMKO" 282D 1/4" ELEVATOR <br />X <br />Q IMPERVIOUS SURFACE <br />> <br />X <br />Q <br />00 <br />o °° <br />> <br />Q <br />IMPERVIOUS SURFACE <br />AD 55 <br />J <br />o m <br />�� * IMPERVIOUS SURFACE AD 55 <br />LAP <br />TYP B <br />STEP02 PAN FLASHING* - SOLDER ALL JOINTS. <br />cn O <br />AD 55 <br />O <br />WHEN "L" FLASHING HAS LESS THAN A 2" <br />* <br />O <br />* <br />iv SLOPE PER PLAN <br />* <br />o <br />SLOPE PER PLAN <br />" <br />o <br />" <br />VERTICAL RISE BETWEEN THE DECK AND <br />o <br />X <br />iv <br />PAN, CONSTRUCT PAN AND "L" FLASHING <br />AS INTEGRAL ONE PIECE. COORDINATE <br />N z X <br />N <br />W <br />PAN DEPTH AND LIP HEIGHT WITH EACH <br />SPECIFIC THRESHOLD, FABRICATE PAN <br />N <br />j <br />411 TO MAXIMIZE DEPTH YET ELIMINATE <br />�q THRESHOLD ANCHOR PENETRATIONS <br />THROUGH THE PAN. <br />THRESHOLD PAN SET IN <br />STEP@ "L" FLASHING* <br />THRESHOLD PAN SET IN <br />CONTINUOUS BEADS OF <br />THRESHOLD PAN SET IN <br />CONTINUOUS BEADS OF <br />SEALANT <br />CONTINUOUS BEADS OF <br />411 <br />G'yo <br />SEALANT <br />SEALANT <br />"PEMKO" 158D OFFSET SADDLE SET IN <br />A <br />"PEMKO" 274D SADDLE SET IN <br />SEALANT PER MANUFACTURER <br />"PEMKO" 158D OFFSET SADDLE SET <br />SEALANT PER MANUFACTURER <br />3 THRESHOLD ANCHORS, DO NOT <br />IN SEALANT PER MANUFACTURER <br />\ <br />PENETRATE FLASHING FLASHING PAN <br />d <br />3 THRESHOLD ANCHORS, DO NOT <br />3 THRESHOLD ANCHORS, DO NOT <br />PENETRATE FLASHING PAN <br />"PEMKO" 183D 1/4" ELEVATOR <br />PENETRATE FLASHING PAN <br />p��1P 1pl, <br />ES <br />- <br />23 <br />- <br />1 9 <br />00 fHH <br />T <br />DOOR <br />DOOR <br />T� <br />DOOR FRAME WITH INTEGRAL STOP <br />DOOR FRAME WITH INTEGRAL STOP <br />SECTION BB III <br />FACE OF WALL BEYOND <br />FACE OF WALL BEYOND <br />* COAT GSM "L" AND PAN FLASHING WITH PROTECTIVE MEMBRANE AT <br />INTERIOR FINISH FLOOR <br />INTERIOR FINISH FLOOR <br />WOOD DECKS PER DETAIL 8/AD-55 <br />FLOORING UP TO 1/4" THICK <br />FLOORING UP TO 1/4" THICK <br />DOOR BOTTOM "PEMKO" 345D OR <br />DOOR BOTTOM "PEMKO" 345D OR <br />DOOR FLASHING PAN INSTALLATION <br />3 <br />APPROVED EQUAL, SEAL TO DOOR <br />APPROVED EQUAL, SEAL TO DOOR <br />W.R.B. WEATHER RESISTIVE BARRIER (W.R.B.), TWO -PLY WEATHER TEX BY FORTIFIBER <br />* <br />BUILDING SYSTEMS GROUP. SUPER JUMBO TEX 60 MINUTE BUILDING PAPER OVER <br />w <br />W <br />WEATHERSMART HOUSE WRAP. <br />S.A.F. SELF ADHESIVE, HEALING FLASHING (S.A.F.) 12" WIDE (U.N.O.) 25 MIL (U.N.O.) <br />0 g <br />O 2 <br />THRESHOLD STOP, "PEMKO" 1842DS <br />_ _ _ _ FORTIFIBER FORTIFLASH OR APPROVED EQUAL. ADHERE S.A.F. TO CLEAN, DUST <br />W <br />W O <br />W <br />0 <br />OR APPROVED EQUAL SET IN <br />FREE BACKING USING CHEMICALLY COMPATIBLE MATERIALS AND/OR PRIMERS. <br />o <br />> <br />� <br />CONTINUOUS BEAD OR SEALANT <br />PROVIDE SOLID WOOD BACKING OR SHEATHING BEHIND ALL AREAS TO RECEIVE <br />x> <br />Q <br />Q 00 <br />HARDSCAPE <br />Qco <br />FINISH <br />SELF ADHESIVE, HEALING FLASHING. <br />* <br />0 <br />co O <br />N <br />� O <br />- <br />FLASHING MULTI -LAYERED COMPOSITE POLYOLEFIN FLASHING 12" WIDE (U.N.O.) <br />x <br />SLOPE PER PLAN <br />�0 0 <br />I <br />FORTIFIBER MOISTOP NEXT OR APPROVED EQUAL <br />I I <br />GSM FLASHING GSM FLASHING METAL SHALL BE SHOP FABRICATED USING A MINIMUM 26 GA. <br />N z <br />a <br />d <br />a I I <br />d <br />BONDERIZED GALVANIZED SHEET METAL WITH SOLDERED JOINTS U.N.O.. STUCCO <br />_N <br />I <br />° <br />"PEMKO" 158D OFFSET SADDLE SET <br />° a <br />a <br />°° <br />° ° <br />ACCESSORIES SHALL BE CEMCO WATER MANAGEMENT SERIES, 25 GA. MATERIAL <br />7t <br />a a° <br />I <br />a <br />a IN SEALANT PER MANUFACTURER <br />a <br />a <br />PEMKO„ SADDLE SET IN SEALANT <br />WITH A G-90 GALVANIZED COATING OR ARCHITECT APPROVED EQUAL, UNLESS <br />d <br />° ° <br />I I <br />° PER MANUFACTURER <br />NOTED OTHERWISE. <br />a° a <br />THRESHOLD PAN SET IN CONTINUOUS <br />° <br />a a <br />BEADS OF SEALANT <br />a <br />a a <br />CORNER FLASH CORNER FLASHING MEMBRANE WITH A RUBBERIZED ASPHALT CORE <br />d41 <br />TLS LABS. GS 100 SERIES OR APPROVED EQUAL <br />Q <br />J ° _ <br />"PEMKO" 183D 1/4" ELEVATOR <br />4a <br />BOND BREAKER POLYETHYLENE TAPE TO BE USED AS BOND BREAKER, REQUIRED BETWEEN <br />CONCRETE ANCHOR, PROVIDE <br />CONCRETE ANCHOR, PROVIDE <br />ACRYLIC PLASTER AND PAINT FINISHES AND ALL WEEPING SOLID LEG FLASHING. <br />INTERIOR <br />° EXTERIOR <br />THREE ANCHORS MINIMUM <br />INTERIOR <br />CORRIDOR THREE ANCHORS MINIMUM <br />TAPE SHOULD RUN FROM THE SOLID VERTICAL LEG TO 1/8" FROM FRONT EDGE. <br />ANY APPLIED FINISH THAT CREATES A BOND BETWEEN THE PLASTER AND METAL <br />SHALL BE BROKEN WITH UTILITY KNIFE AND SHALL BE MAINTAINED AS SUCH. <br />SEALANT ® POLYURETHANE SEALANT FORTIFIBER MOISTOP SEALANT OR APPROVED EQUAL. <br />AT A MINIMUM, EXPOSED SEALANT SHALL BE CHECKED ANNUALLY AND <br />MAINTAINED PER MANUFACTURERS RECOMMENDATION TO MAINTAIN A WATER <br />TIGHT SEAL. <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />4 <br />D <br />FOR ADDITIONAL INFORMATION SEE <br />DETAILS 3 4 <br />NOTE: CAULK ENDS OF THRESHOLDS, AND UNDER FULL LENGTH OF LEGS TO DOOR <br />FLASHING PAN TO MAINTAIN WATER TIGHT INSTALLATION. <br />- <br />24 <br />- <br />20 <br />UNIT DOOR @ <br />BALCONY/ DECK <br />16 <br />UNIT DOOR @ <br />BALCONY/DECK <br />12 <br />UNIT PRIMARY <br />DOOR @ INT. CORRIDOR <br />8 <br />NOTES <br />4 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />E I] Q A K <br />INVESTMENTS <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />i <br />r <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />w <br />w <br />U) <br />F_ <br />ICT <br />LO <br />r <br />L0 <br />015 <br />Nt <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />��SED ARCh,�T <br />,A <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />s�gTF <br />OF C A� <br />License Stamp <br />EXTERIOR DOOR <br />FLASHING DETAILS AT <br />STUCCO <br />AD-5200 <br />Z <br />^J <br />L.L <br />r <br />I-n <br />V <br />ILL <br />N <br />N <br />C) <br />N <br />r <br />C) <br />00 <br />O <br />COPYRIGHT U <br />