ROOF FRAMING AND SHEATHING PER
<br />STRUCT. DRAWINGS, FRAMING AND S�pP�� ROOF SIDE - TOP OF PARAPET PER E ROOF SIDE TOP OF PARAPET PER
<br />PLYWOOD SUBSTRATE TO SLOPE AS 1' EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS
<br />SHOWN ON ARCHITECTURAL ROOF 1 1 TPO ROOFING, UP BACK OF 3 3
<br />PLAN (1/4": V-0" MINIMUM LOW PARAPET WALL AND 2 GSM "COPING" FLASHING
<br />- C
<br />-EXTERIOR CEMENT PLASTER
<br />ONTO TOP OF WALL. SEE •
<br />DETAIL
<br />I
<br />C 1x PLASTER STOP 0/ FLASHING
<br />CONTINUOUS 1/2" BEAD OF SEALANT 0/ W.R.B.
<br />ALL FOUR SIDES OF GSM "COLLAR"
<br />I
<br />FLASHING
<br />SCUPPER OPENING 2 SPECIFIED TPO ROOFING SYSTEM
<br />W.R.B. Architecture + Planning
<br />�I I
<br />V 17911 Von Karman Ave.
<br />GSM CONDUCTOR HEAD, PRIME AND l _(3 )GSM "INSIDE CORNER" FLASHING, LAP
<br />PAINT ROOF SIDE ROOFING AS DETAILED AND EXTEND Suite 200
<br />el 6 2 TO TOP OF LOW PARAPET WALL
<br />I Irvine, CA 92614
<br />INSERT CONDUCTOR HEAD INTO — METAL PANEL -INSTALL PER ktgy.COm
<br />DRAIN LEADER � _ �\ \ PARAPET FLASHING ASSEMBLY PART I MANUF. GUIDELINES
<br />949.851.2133
<br />2x SOLID BACKING REQUIRED — I
<br />4 TPO ROOFING 0/ GSM "INSIDE KTGY Project N o : 201 7-0934
<br />CORNER" FLASHING AND TPO
<br />GSM DRAIN LEADER SUPPORT BAND L= ROOFING SYSTEM
<br />PROVIDE AT FLOOR LINE AND AT Project Contact:
<br />5 FLASHING, 2" MIN. LAP 0/ ROOFING Debbie Holland
<br />MID -FLOOR TYPICAL, 6' 0" O.C. MAX. CAP SHEET Email: dholland@ktgy.com
<br />ATTACH BAND WITH STAINLESS STEEL ,t gy,com
<br />SCREW WITH WATERTIGHT WASHER;
<br />PRE -DRILL AND FILL HOLE WITH CAULK
<br />1,
<br />Principal: Wil Wong
<br />GSM DRAIN LEADER, PRIME AND Project Designer: D. Schoolmeester
<br />PAINT. SIZE AS INDICATED PER PLAN.
<br />SPECIFIED TPO ROOFING SYSTEM
<br />Project Director: Debbie Holland
<br />I I I
<br />TPO COVER STRIP
<br />I I
<br />Developer
<br />SCUPPE WIDTH
<br />PER ILAN GSM "SCUPPER AND OVERFLOW"
<br />FLASHING, SET IN PLY OF SEALING
<br />SCUPPER OPENING MASTIC SPECIFIED T.P.O. ROOFING SYSTEM
<br />1 MECH. FASTENER SPACING AND E A
<br />LINE OF WALL FINISH TOP OF SCUPPER II\ VES
<br />2" HIGH OVERFLOW ALIGNED WITH ATTACHMENT PER MANUF.
<br />`I MEN"1 S
<br />GSM "SCUPPER AND OVERFLOW" ROOF SIDE EXTERIOR
<br />SIDE HI -TEMP S.A.F. AT FASTENERS
<br />I FLASHING, ROOF SIDE PARAPET FLASHING ASSEMBLY PART II MINIMUM 5/8" EXTERIOR GRADE 4199 CAMPUS DRIVE
<br />W.R.B., TUCK UNDER FLASHING 3" PLYWOOD WALL SHEATHING BEHIND
<br />I MINIMUM. CONTINUE WEATHERBOARD
<br />ROOFING I RV I N E CA 92612
<br />INSTALLATION '
<br />2 2 i INTEGRAL 7/8" STUCCO SCREED ALL PHONE NO. (714) 342-2502
<br />FOUR SIDES, TYPICAL '
<br />p�TN PER --(6 )GSM "SPRING-LOK" g
<br />VERIFY �� + 1" 5" FLASHING, SEE DETAIL _
<br />WIp
<br />TH I
<br />PLAN +RPE 41,
<br />I I
<br />- 7 9" WIDE S.A.F., PROVIDE SOLID
<br />�o ALIGN i BLOCKING BEHIND S.A.F. IF
<br />SHEATHING IS NOT REQUIRED
<br />a HIGHEST POINT OF ROOF HIGHEST POINT OF ROOF
<br />LEADER SIZE i I 77 SEE ROOF PLAN SEE ROOF PLAN
<br />PLUS 1" I L
<br />N r 8 ONE PIECE SOLDERED 12
<br />i /� GSM "SADDLE" c EXTERIOR CEMENT PLASTER 0/ WIRE
<br />EQ 1/4" DRAIN EADER 1/4 EQ LEADER SIZE EQ
<br />PLUS 3/8" IT MAX.) i FLASHING, SEE DETAIL
<br />MINU ,/4' i � �/ LATH 0/ W.R.B.
<br />I I
<br />I I
<br />I I
<br />WALL FRAMING PER STRUCTURAL
<br />DRAWINGS O
<br />ROOF SIDE I`
<br />5 j PENETRATION OPENING TO BE 1" PARAPET FLASHING ASSEMBLY PART III CV
<br />j WIDER AND TALLER THAN THE SHEATHING MAY OCCUR
<br />L _ _ _ _ L SCUPPER TO ALLOW 1/2" WIDE UJ <
<br />9 GSM INTEGRAL
<br />WIDTH OFSCUPPER I SEALANT JOINT ON ALL SIDES OF U
<br />PL S2" I 1/4" 1/4"
<br />BETWEEN SCUPPER AND COLLAR STUCCO SCREED ALL 12
<br />I
<br />FLASHING THREE SIDES, SEE DETAIL ROOF FRAMING AND SHEATHING PER Q
<br />STRUCTURAL DRAWINGS, FRAMING Z
<br />PROVIDE 1/4" ROLLED OR ANGLED 10 1x PLASTER STOP A A AND PLYWOOD SUBSTRATE TO SLOPE Q
<br />ELEVATION PROFILE STUCCO GROUND EDGE TO PERMIT \V V AS SHOWN ON ARCHITECTURAL ROOF
<br />4 22 SCUPPER AND OVERFLOW GSM "COLLAR" FLASHING, PLASTER TO KEY UNDERNEATH THE 4 4 PLAN (1/4": 1' 0" MINIMUM)
<br />FOR ADDITIONAL INFORMATION SEE DETAIL EXTERIOR SIDE AWAY FROM ROOF EDGE ,\ FOR ADDITIONAL INFORMATION SEE DETAIL FOR ADDITIONAL INFORMATION SEE DETAIL z
<br />O()
<br />CONDUCTOR HEAD & DOWNSPOUT 22 GSM SCUPPER & OVERFLOW 14 PARAPET FLASHING, MTL. PANEL 6 PARAPET FLASHING, CAP SHEET 2
<br />w
<br />/ METAL STRAP WITH SCREWS 8" MIN. (TYP.) ROOF SIDE FACE OF PARAPET OR NOTES: / ao� GSM COPING FLASHING NOTES w
<br />ATTACHED TO ALLOW FOR �% CURB WHERE OCCURS 1. SEE PLUMBING DOCUMENTS FOR 11 GSM "COPING" FLASHING JQ �P��S 1. GSM "ROOF" FLASHING SHALL BE
<br />MOVEMENT OF PIPING SPECIFIED ROOF AND OVERFLOW EXTEND BACK TO GSM FABRICATED FROM G90 COATED ® DRAINS, DRAIN LEADERS AND "SADDLE" FLASHING, Q'oJ�� STEEL. Q
<br />ADDITIONAL INFORMATION NOT SEE DETAIL �' i 2. ALL FLASHING SEAMS, LAPS AND U)
<br />PIPE OR CONDUIT SHOWN HERE. ROOF SIDE i JOINTS SHALL BE SEALED. z
<br />2. STEEL FLASHING CLAMP AND UNDER 3. CORNER COPINGS SHALL BE SHOP
<br />- DECK CLAMP SHALL BE USED ON ALL PARAPET FLASHING ASSEMBLY PART IV FABRICATED AND SOLDERED
<br />— q , , ROOF AND OVERFLOW DRAINS. i WATERTIGHT.
<br />3. ROOFING MEMBRANE SHALL BE T 4. PROVIDE CONTINUOUS WOOD uJ EXTENDED UNDER STEEL FLASHING EXTERIOR CEMENT PLASTER 0/ WIRE .o
<br />� o-- �1 J/ �0IN S BACKING THAT IS SLOPED 1": 1'-0" TO
<br />LATH 0/ W.R.B. �'`�9 '�! `� �O N R � LO
<br />CLAMP. , B��o GsP� SIO ATE THE ROOF SIDE.
<br />o O O O O O O O O _ 4. OVERFLOW DRAIN SHALL BE FITTED 9�� oq� PP� o GE 5. EXTEND THE TPO ROOFING UP OVER
<br />Fv 0 O O o �� 20� E� I0'0 THE TOP OF THE WALL UNDER METAL
<br />LO
<br />4x4 MINIMUM REDWOOD BLOCKING 1 O 0 0 O � 1 O 0 0 O � WITH 2" HIGH SOLID WATER DAM. T
<br />O 0�� O O 0�� O 5. WHEN ROOFING INSTALLATION IS i � ��T P COPING, TYP. �S
<br />6. ON THE ROOF SIDE, COPINGS ARE
<br />SPACED AT 6'-0" O.C. -FIELD VERIFY \ Oa �� � COMPLETE, CONTRACTOR SHALL � \ � �coq FASTENED THROUGH OVERSIZED OR
<br />(2) DABS OF ROOF CEMENT PLACED \ �00� \ �00r INSPECT AND TEST ALL ROOF DRAINS i 'moo '� LO
<br />BETWEEN BLOCK AND PAD o _ _ i _ _ i TO ASSURE THAT DRAINAGE SYSTEM CORNER COPING LAP BUTT JOINT SLOTTED HOLES. V_
<br />yy� (SPECIFIED) WALK PAD AT PIPES OR IS NOT CLOGGED. � � � SOLDER MITERED CORNERS 7. ON THE SIDE AWAY FROM THE ROOF,
<br />CONDUIT UP TO 1" DIAMETER OR 1/2" \ WATERTIGHT CLEATS FASTENED AT 18" O.C. WITH
<br />THICK RUBBER WALK PADS AS CORROSION RESISTANT FASTENERS.
<br />DISTRIBUTED BY THE MEADOWS CO. 8. FASTENERS ARE NOT ALLOWED AT
<br />oe- 9 & 10 PER GSM "COPING" FLASHING SLOPING HORIZONTAL SURFACES.
<br />AT PIPES AND CONDUITS GREATER P�a`�5 9. USE BUTT JOINT WITH BACKUP PLATE
<br />1'-0" 2'-0" 1'-0" � `
<br />THAN 1" DIAMETER. 2" HIGH SOLID WATER DAM AT JQ �' "
<br />4'-0" OVERFLOW DRAIN ,� �' � B-Q AT COPING WIDTHS UP TO 18 . SEE
<br />PLAN i ,I `aP J� i ROOF SIDE VERIFY WALL WIDTH SIDE AWAY FROM SMACNA TABLE 3-1, JOINT J2
<br />UNI-STRUT LAP ROOF MEMBRANE UNDER
<br />i SLOPE TOP OF THE ROOF 10. USE BUTT JOINT WITH COVER AND
<br />CLAMPING RING, TYPICAL COPING AT BACKUP PLATES AT COPING WIDTHS
<br />i 1": V-0" MINIMUM
<br />OVER 18". SEE SMACNA TABLE 3-1,
<br />SPECIFIED TPO ROOFING JOINT J5.
<br />_ SYSTEM ROOF SIDE EXTERIOR SIDE \ i / 0 v. 1/Z 0���$ cCIOw �� \ 7 22 GA. GSM CLEAT
<br />R 3�a.J
<br />/ 4x �(P PP0�310 ATE M — & O5 WOOD BACKING
<br />PARAPET FLASHING COMPLETED ASSEMBLY E0,
<br />__(6 )STAINLESS STEEL SCREW WITH
<br />ROOF SHEATHING AND TRUSS PER NOTE: 3/8" 3/8" WATERTIGHT WASHER AT 24" O.C. No. Date Description Iff—
<br />STRUCTURAL DRAWINGS LAP ALL FLASHING AND THE WATER RESISTANT BARRIER IN WEATHERBOARD FASHION. COPING LAP BUTT JOINT GSM "COPING" FLASHING; USE 22 GA.
<br />2 4 6 TO 12" COPING WIDTH, 20 GA. OVER M
<br />NOTE: 2x SUPPORT FRAMING AT ROOF DRAIN FOR ADDITIONAL INFORMATION SEE DETAIL 12" COPING WIDTH. SEE FLASHING W
<br />1. NO FASTENERS SHALL PENETRATE THE ROOFING MEMBRANE. SECTION PRIMARY ROOF DRAIN ROOF OVERFLOW DRAIN DEPRESSION NOTES ABOVE.
<br />PIPE CONDUIT SUPPORT 23 ROOF DRAIN & OVERFLOW 15 LOW PARAPET FLASHING HIGH PARAPET WALL 11 GSM COPING FLASHING 3 U)
<br />@ �e
<br />1-HR RATED WALL PER PLAN I U
<br />� PROVIDE 1/4" ROLLED OR ANGLED
<br />FRAMING PER STRUCTURAL HOLLOW METAL DOOR PER DOOR ' VERIFY EQUIPMENT SIZE AND COPING STUCCO GROUND EDGE TO PERMIT W
<br />SCHEDULE t __--------VERIFY
<br />REQUIRED CLEARANCES WITH WIDTH + 3/4" PLASTER TO KEY UNDERNEATH THE I
<br />PAINTED GSM STATIC AURA TYPE 2x SOLID BACKING REQUIRED AT S.A.F. i HOLLOW METAL DOOR FRAME ALL EQUIPMENT MANUFACTURER, EDGE U
<br />ATTIC VENT, SIZES AND LOCATIONS WHEN SHEATHING NOT PROVIDED ® \ i EQUIPMENT PER M.P.E. PLANS
<br />AS SHOWN ON THE ROOF PLAN 4 SIDES PER DOOR SCHEDULE ® � � CEMCO # 66 EXPANDED FLANGE 7
<br />SHEATHING MAY OCCUR DOOR SEAL "PEMKO" S88D ALL 4 \ Y / MASON INDUSTRIES TYPE SR SPRING oo CASING BEAD Lz
<br />CORROSION RESISTANT SHEET SIDES, OR APPROVED EQUAL co N
<br />METAL SCREW, SEAL WATER TIGHT 2 HOLLOW METAL DOOR FRAME DOOR BOTTOM "PEMKO" 3452DV OR \ -�'_ J ISOLATOR HAVING 1" OF STATIC U) N J
<br />IN PER DOOR SCHEDULE -;� DEFLECTION. VERIFY QUANTITY AND W It is the clients responsibility prior to or during construction to notify the architect in writing
<br />APPROVED EQUAL, SEAL TO DOOR \== PLACEMENT REQUIRED. SET IN A BED
<br />of any perceived errors or omissions in the plans and specifications of which a contractor
<br />GSM "CURB" FLASHING MOUNTED "r OF SEALANT. Q 7/8" thoroughly knowledgeable with the building codes and methods of construction should
<br />METAL DOOR FRAME 4 SIDES �,�,;
<br />\ �� / -7-r J �� �� reasonably be aware. Written instructions addressing such perceived errors or omissions
<br />GSM COPING FLASHING �^
<br />FLASHING FLANGE WITH DRIP, shall be received from the architect prior to the client or clients subcontractors proceeding v,
<br />PAINTED. THRESHOLD PAN SET �� �� �= ;; _ 22 GA. GSM "CAP" FLASHING, ALL with the work. The client will be responsible for any defects in construction if these
<br />IN CONTINUOUS BED SEAMS SHALL BE FLAT LOCK LENGTH OF ROOF SIDE LEG SHALL procedures are not followed.
<br />STAINLESS STEEL SCREW WITH I OF ROOF CEMENT - EXTEND DOWN TO GSM "SPRING-LOK"
<br />WATERTIGHT WASHER AT 12" O.C. SOLDERED 0/ ROOFING MEMBRANE FLASHING
<br />LAP BASE AND CAP SHEET SWEAT SHEET 0/ PLYWOOD �\ USED ARC, ,l U_
<br />MINIMUM TWO PER SIDE 3" MIN. ONTO SILL PLATE w a GSM "SPRING-LOK" FLASHING
<br />2x8 P.T. CURB ALL AROUND. I ° ° 'ofGSM INTEGRAL STUCCO SCREED �uR %?�O
<br />o
<br />a e ° ° m 2x PLATFORM FRAMING AND N
<br />ZO
<br />CONNECTIONS TO SUPPORTS BELOW „ N
<br />WALKING PAD m I N PER STRUCTURAL PLANS 6 No. C29795
<br />0g RENEWAL DATE (V
<br />\ w �ERIF� i / AUGUST 31, 2023
<br />SPECIFIED T.P.O. ROOFING SYSTEM c�� ° < SPECIFIED T.P.O. SYSTEM SOLID BLOCKING OR SHEATHING �'9/
<br />DOOR SEAL "PEMKO" S88D OR REQUIRED BEHIND 1" MINIMUM AND F �F CAll-
<br />APPROVED EQUAL BEYOND COPING FLANGE.
<br />0.
<br />z0 T.P.O. ROOFING INSTALL PER MANUF. ��-
<br />WRAP S.A.F. INTO JAMB AND DOWN 0/ a? ��'Pi License tamp Ip
<br />REQUIREMENTS. RUN UP AND OVER
<br />DOOR FLASHING PAN AND "L" METAL No CURB
<br />FLAT STOCK
<br />HOLLOWMEFLASHING
<br />LDOOR, THRESHOLD �� J TPO ROOFING DETAILS
<br />ROOF FRAMING AND SHEATHING PER JAMB ON HOLLOW METAL DOOR, TYP. ``� � �
<br />STRUCTURAL DRAWINGS, FRAMING
<br />BACKER ROD &SEALANT
<br />AND PLYWOOD SUBSTRATE TO SLOPE
<br />ROOF SHEATHING moo SLOPE TO MATCH 3
<br />AS SHOWN ON ARCHITECTURAL ROOF W.R.B. 0/ 4" J-SERIES CASING BEADFRAMING, BLOCKING, ROOF TRUSS GSM "COPING" FLASHING,
<br />PLAN (1/4": V-0" MINIMUM) 0/ S.A.F. ROOF TRUSSES BY OTHERS woe ��� J
<br />3 COAT STUCCO SYSTEM 0/ METAL Sao AND SHEATHING PER STRUCTURAL a i SEE DETAIL
<br />STAIR LANDING FRAMING PER CRICKET REQUIRED AT HIGH 16 PLANS 6" 2x SOLID BLOCK BETWEEN TRUSS LATH 0/ W.R.B. STRUCTURAL SIDE OF ROOF PLATFORM IF V
<br />TOP CHORD, BLOCK ALL AROUND WIDTH IS GREATER THAN 30"
<br />FOR ADDITIONAL INFORMATION SEE DETAIL 4 JAMB FIRE BARRIER AT EXIT ENCLOSURE -
<br />SEE PLAN FOR FIRE RATING VERIFY AND COORDINATE ALL BUILT-UP ROOFING DETAILS WITH MANUFACTURER AND INSTALL IN CONFORMANCE WITH MANUFACTURERS REQUIREMENTS FOR WARRANTY SPECIFIED GSM "SADDLE" FLASHING BLOCKING
<br />ATTIC VENT 24 DOOR AT ROOF 16 MECHANICAL PLATFORM 8 GSM "SADDLE" FLASHING & INTEGRAL STUCCO SCREED 4 AD-61
<br />COPYRIGHT n
<br />
|