My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 4:26:33 PM
Creation date
8/14/2023 7:49:24 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
23
Date
12/6/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3-COAT STUCCO SYSTEM 0/ W.R.B. <br />TRUSS HEEL MAY VARY SEE ROOF <br />PLAN/ ELEVATIONS <br />SHEATHING MAY OCCUR <br />ROOF SHEATHING PER STRUCTUR <br />2X BACKING AT GALV. MTL. FLASHING <br />ROOF UNDERLAYMENT LAP OVER <br />WEEP SCREED'J' METAL 0/ Z BAR <br />RIDGE OR HIP TILE <br />EAVE RISER <br />NAILER PER TILE MFG. <br />BATTENS PER TILE MFGR. <br />26 GA. GALV. MTL. "Z" BAR FLASHING <br />2x BLOCKING <br />1 0/ S.A.F. PRIME & PAINT TO MATCH <br />ROOF TILE - SEE ROOF PLAN - <br />I SIDING <br />INSTALL PER MFGR. <br />ROOF TILE - SEE ROOF PLAN - <br />I <br />INSTALL PER MFGR. <br />M <br />1X6 BACKER BOARD <br />ROOF UNDERLAYMENT <br />UNDER AND OVER NAILER <br />STARTER BOARD <br />' CONCRETE'S' ROOF TILE <br />L_ <br />INSTALL PER MFGR. <br />ROOF SHEATHING PER STURCTURAL <br />EAVE RISER WITH WEEP HOLES <br />PER ROOF TILE MFGR. <br />BATTENS PER TILE MFGR. <br />ROOF FRAMING <br />EDGE DRIP METAL <br />ROOF UNDERLAYMENT LAP UP WALL <br />w <br />J <br />— <br />~ <br />3„ <br />" 8MIN WEATHERBOARD LAP W/FIELD <br />MAN <br />RADIANT <br />T <br />Of <br />ROOF FELT <br />BARRIER � SEAMLESS ALUMINUM <br />� <br />PREFINISHED 4" OGEE GUTTER <br />WHERE OCCURS, SEE ROOF <br />PLAN <br />2x4 FASCIA BOARD <br />PER ROOF PLAN <br />3-COAT STUCCO SYSTEM <br />0/ W.R.B. <br />NOTES: 1. REFER TO TILE MFGR. SPECIFICATIONS FOR INSTALLATION OF TILE REQUIREMENTS <br />W.R.B. <br />ROOF SHEATHING & <br />2. PROVIDE NAILING AND WIND CLIPS PER MFGRS. INSTALLATION <br />SHEATHING MAY OCCUR <br />FRAMING PER STRUCT <br />FRAMING PER STRUCTURAL <br />117 <br />'S' TILE -ROOF TO WALL <br />ROOF TILE-RIDGE/HIP <br />5 <br />ROOF TILE-EAVE <br />1 <br />3-COAT STUCCO SYSTEM 0/ W.R.B. <br />36" WIDE 72 POUND UNDERLAYMENT <br />ROOF TILE - SEE ROOF PLAN <br />CENTERED ALONG LENGTH OF <br />INSTALL PER MFGR. <br />VENT PIPE <br />MIN. 26 GA, GALV, MTL <br />SHEATHING MAY OCCUR <br />VALLEY <br />BATTENS PER TILE MFGR. <br />COUNTER FLASHING W/ <br />2X BACKING AT GALV. MTL. FLASHING <br />ROOF UNDERLAYMENT UNDER <br />ROOF UNDERLAYMENT <br />LEAD FLASH'G <br />GASKET AT TOP, <br />WEATHERBOARD LAP W/ <br />VALLEY FLASHING WEAVE <br />LAP DOWN BARGE BOARD 1" <br />ROOFING, SEAL TO <br />WEEP SCREED'T METAL 0/ Z BAR <br />ACROSS VALLEY MIN. 12" EACH <br />ROOF SHEATHING PER <br />ROOFING TILE - SEE <br />ROOFING W/ ROOFER'S <br />SIDE <br />STRUCTURAL <br />ROOF PLAN <br />MASTIC - PER CLASS 'A' <br />26 GA. GALV. MTL. "Z" BAR FLASHING <br />26 GA. GALV. MTL. VALLEY <br />1X6 FIRE RETARDANT TREATED <br />ROOFING MFG. <br />0/ S.A.F. PRIME & PAINT TO MATCH <br />FLASHING. INSTALL PER <br />T&G WOOD STARTER BOARDS AT <br />—RECOMMENDATIONS, <br />I� <br />STUCCO <br />ROOFING MFGR. LAP ANY <br />EXPOSED EAVES, FULL BODY <br />JOINTS 6"MIN &SEAL. <br />STAINED <br />1X6 BACKER BOARD <br />f— RAKE SEAL INSTALL PER MFR. <br />CY' <br />ROOF TILE - SEE ROOF PLAN - NO <br />SPECS. <br />CONCRETE'S' ROOF TILE <br />FASTENERS IN VALLEY FLASHING <br />INSTALL PER MFGR. (NO NAIL <br />EDGE METAL <br />L <br />PENETRATIONS INTO FLASHING PAN) <br />3x8 BARGE BOARD <br />R OF PLAN <br />SOLDER ALL <br />I <br />AROUND LEAD & <br />COUNTER FLASH'G <br />J <br />SEALANT &BACKER ROD <br />,, <br />u? <br />MCB <br />2X4 FLAT AT 24" O.C. <br />ROOF TRUSS <br />RETURN (2) TRUSS BAYS <br />PROVIDE 2X4 CRIPPLERS @ 24" <br />\ \ <br />O.C. FOR LATH SUPPORT AT <br />PROVIDE SEALANT IN ROOF <br />RAKE ENDS OR GABLE END <br />SHT'G AROUND POLE <br />TRUSS <br />BATTEN EXTENDERS PER TILE MFGR DO NOT <br />PENETRATE FLASHING PAN <br />ROOF SHEATHING & FRAMING <br />RADIANT BARRIER <br />j <br />LEAD FLASHING <br />PER STRUCTURAL DRAWINGS <br />ROOF UNDERLAYMENT LAP UP WALL 8" MIN. <br />3-COAT STUCCO SYSTEM <br />(2) LAYERS MIN, 3011 ROOF <br />ROOF SHEATHING <br />0/ W.R.B. <br />FELT WEATHER BOARD <br />MAN <br />LAP W/ BASE FLASHING <br />26 GA. GALV. MTL. ROOF TO RAKE WALL <br />�t 36 <br />W.R.B. <br />FLASHING PAN. NO PENETRATIONS TO <br />SHEATHING MAY OCCUR <br />OCCUR THROUGH FLASHING PAN <br />FRAMING PER STRUCTURAL <br />ROOF AND WALL FRAMING PER STRUCT. <br />NOTE: NO PENETRATIONS TO OCCUR THRU VALLEY FLASHING <br />18 <br />VENT THROUGH ROOF <br />14 <br />'S' TILE -RAKE TO WALL <br />10 <br />ROOF TILE -VALLEY <br />6 <br />ROOF TILE -RAKE <br />2 <br />REFER TO DETAIL 3 <br />FOR ALL INFO. <br />NOT SHOWN HERE. <br />5/8" GYP. BD. AROUND <br />PERIMETER OF OPENING <br />0 <br />�I <br />BOTTOM CORD <br />2X3 BARGE BOARD <br />OF TRUSS 1/2" PLYWOOD <br />EO <br />X_� <br />2X2 SPACER <br />OPENING SIZE <br />GYP. BD. CEILING 3/4' PER PLAN 3/4" <br />PROVIDE GYP. BD. <br />J-MOULD AT PERIMETER <br />[GYP. <br />OF OPENING BD. (THICKNESS TO MATCH <br />CEILING GYP. BD.) ATTACH TO <br />1/2" PLYWOOD <br />PROVIDE GYP. BD. <br />3-COAT STUCCO SYSTEM <br />J-MOULD AT PERIMETER <br />0/ W.R.B. <br />OF GYP. BD. PANEL <br />i <br />19 <br />15 <br />NON -RATED ATTIC ACCESS <br />11 <br />7 <br />ROOF TILE -TIGHT RAKE <br />3 <br />ROOFING AND ROOF ASSEMBLY PER MORTAR FILL <br />PLAN AND DETAIL <br />GAL. MET. CAP FLSH'G OVER HIGH TEMP S.A.F. <br />22" x 30" H.M. ACCESS <br />I <br />PANEL <br />(2) 2X BLOCKING @ ACCESS PANEL <br />FRAME CONDITION <br />TPO MEMBRANE <br />SEALANT <br />"PLYCO" NO.W-1424 VENT. <br />WEEP SCREED <br />LOUVER INSERT <br />'T METAL <br />18 GA. GALV. MTL. FLASHING, <br />ATTIC VENT LOUVER WITH PAINTED <br />EXTEND PAN 2" PAST <br />NON-COMBUSTIBLE METAL =- ROOF TRUSSES @ 24" O.C. <br />EAVE CUT, TUCK BACK <br />MESH SCREEN -1/6" TO 1/8" REFER TO STRUCTURAL <br />UNDER PAN AND SEAL <br />MAX w w <br />— — <br />1 1/2" H.M. ACCESS PANEL o <br />PROVIDE PERIMETER C„ J <br />26 GA GALV MTL ROOF <br />WEATHER SEAL GASKETS N <br />LATCH W/ TURN LOCK W <br />TO WALL FLASHING PAN <br />WITH NON-COMBUSTIBLE METAL CC <br />NO PENETRATIONS TO <br />EMBER RESISTANT MESH o <br />OCCUR IN PAN <br />SCREEN -1/6" TO 1/8" MAX = J <br />o�_ <br />r x= <br />CV <br />ROOF UNDERLAYMENT <br />LZI <br />LAP UP WALL <br />PIANO HINGE <br />18 GA. GALV. MTL. SILL 3 <br />SIM. <br />FLASHING, PAINTED AD-52 <br />EDGE METAL <br />ATTIC ACCESS DOOR <br />r <br />(2) 2X BLOCKING @ ACCES <br />PANELFRAME <br />HEAT WELDED TPO MEMBRANE <br />2X FASCIA <br />TPO ROOF MEMBRANE O/ 1/4" DENS DECK co <br />0/ 1" THICK APPROVED RIGID INSULATION <br />0/ PLYWOOD SHEATHING <br />NOTES: GUTTER NOT SHOWN FOR CLARITY <br />201 <br />161 <br />RAKE TO WALL DIVERTER <br />121 <br />ATTIC ACCESS PANEL <br />4 <br />OF x <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED7 OAK <br />INVESTMENTS <br />4199 CAMPUS DRIVE <br />I RVI N E, CA 92612 <br />PHONE NO. (714) 342-2502 <br />T_ <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />w <br />w <br />U) <br />w <br />T_ <br />L0 <br />06 <br />LO <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />SED ARC111,T <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />of CA\-\ <br />License Stamp <br />CONCRETE FLAT TILE <br />ROOF DETAILS <br />AD-61 02 <br />z <br />Q <br />J <br />V / <br />ILL <br />COPYRIGHT U <br />
The URL can be used to link to this page
Your browser does not support the video tag.