EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />54 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />10.8" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4 <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />54 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />16.2" <br />PROPOSED STAIR WIDTH <br />48" <br />I I I I <br />I <br />I I I I 1 <br />1 I I <br />I I I I <br />I I <br />I I I I I <br />I I I <br />I t <br />P I1 <br />I <br />I <br />I I I <br />I I <br />I I I I I I <br />1 1 I FEC ' <br />FEC_______+_________ ________________ ________+______ <br />__ _________ _________________ _______+_________ ___+__ _ _____ ____+_t___ ______+ <br />16V-10,, <br />I--------� <br />I <br />I <br />1/3 OVERALL DIMENSION _ <br />1 <br />EXIT-- <br />--------------- <br />---- --- <br />-----------------------r-mp <br />I <br />UP 5% <br />I <br />I <br />I <br />I <br />I <br />� <br />I <br />I <br />I <br />I <br />i <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />53 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />10.6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />30 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.41, <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />83 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />24.9" <br />PROPOSED STAIR WIDTH <br />66" <br />ril, <br />F----------------------- --------------- <br />- - - - J - - - - - <br />t� <br />C <br />I- T 7 <br />DWELLING UNIT �-L-i <br />490 1 200 <br />3 il R-2 <br />DWELLING UNIT <br />1286 <br />1 200 <br />7 <br />1R-2 <br />�- - -------------- <br />u • \ <br />DOWN 5% ON 3 <br />EXIT ® EXITS - 71 53 30 ,N 1 <br />I <br />1 1 <br />1 1 <br />1 I I p I <br />' u <br />I <br />I a 1 u <br />J <br />-- -- --� r------- , -� r----- ---� r---------� r---- -- f� � 1 ❑ ==-I <br />I I _______� ch <br />------------------------------------------ -------------------------------- ------ --- --------------------------------- I I <br />I I t------- t- t------ t---------- t---- <br />---�--,--- I I I I ❑ I I I I I I❑ I I I I I I �- -- ----- I <br />I I 1 I I 1 I I I 1 1 I ----- - - - - -- <br />1 II <br />------ ----- i i I I I I I I I I I I I I I I 1 1 I I I 1 II <br />_ _♦ I i I <br />L_______J__J __J L__ <br />-r <br />I <br />4 <br />I <br />I o <br />I U') <br />I a_ <br />I <br />I D <br />I <br />I <br />I I I <br />I I <br />I I I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />❑ r --� <br />I I I <br />I I I <br />I I <br />-------J <br />I I I <br />I I <br />1 <br />fi �Fqs I I I 1 L--------- J 1 co <br />oTs ° F`�q� I I U? 4----------- - <br />t� 1 <br /><�cs oi,�FN I o I 1 L DWELLING UNIT <br />1043 200 <br />0 0 0 0 �Fti0O ,QgTS�O� 20 , 6 R-2 <br />I I I I ti Fo ; s �.s-. I I 1 I--------- - 1 <br />F <br />I I I I 1 C �Z� I I I ; I L J I <br />00 SST I <br />I j ❑ I j I I j I❑ I I I I 1 1 I rn --- � ----- 1 IL--- <br />:. I I 1i ; ; I .. FIRE WALL <br />----------------- --------+------- ---+------- -- - ------------+--------------------------- --------+------ I R <br />V 0 Ir=== <br />_______J <br />212ARKI 200 <br />171 <br />a 107 R-2 1 ---- ------ I IL=== <br />TOTAL PARKING OCCUPANT LOAD = 107 1 I 1 1 DWELLING UNIT <br />107 OCCUPANTS/2 EXITS =53/54 OCC. PER EXIT 1 10643 2R02 <br />I 1 <br />r---------- <br />I I <br />I I <br />I I <br />--------------- ------------- -------1--------- <br />I I <br />I I I I I <br />L_ _ _� __J <br />I I I I <br />I I <br />I <br />`I <br />� <br />I �I l �l r ; . � <br />o❑ I� <br />III <br />I� <br />E <br />oil <br />II. <br />----__� <br />--------------- <br />J..oa <br />------- <br />� <br />F- <br />DWELLING UNIT 11 <br />1126 200 = II <br />6 1 R-2 D u <br />I <br />t= II g WELLING UNIT <br />II 1126 1 200 <br />6 1 R-2 <br />II =_ F <br />-11 <br />II L JI <br />II <br />II <br />u <br />II of <br />u <br />u <br />-n-�-n <br />DWELLING UNIT <br />705 <br />200 <br />4 <br />R-2 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />13 <br />I <br />I II <br />I <br />I <br />I I <br />I <br />I <br />II <br />I I I <br />PE1T -- �- I{ I� <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />30 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4 <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />30 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />9" <br />PROPOSED STAIR WIDTH <br />48" <br />1 <br />I I <br />L 1 <br />1 <br />I - - - <br />I <br />----------------------------------+------------+---- ----- ----- --- - <br />I I I I <br />I I I = 13 1 " (:d <br />I I I I I I ♦ I <br />El <br />44M - - - - - * - <br />1 I I I <br />_ ______ <br />^�� I _. <br />I I <br />C�a II <br />I I <br />o o/) N. o o <br />O <br />DWELLING UNIT <br />424 1 200 <br />�O�P�,\��IiPQPO G i i i;-'--------------------------------------� 3 R-2 <br />I J �J - -1 <br />L � <br />U`l � V <br />-1J�� I DWELLING UNIT <br />I o- <br />E 11 669 1 200 <br />4 1 R-2 EFEC <br />El <br />I <br />I <br />DWELLING UNIT <br />705 <br />200 <br />4 <br />R-2 <br />, <br />1.■T■t <br />� ���li•.CI�� <br />1 w u LL-1 1 - <br />1 <br />= 180'-2" c I 1 <br />FL6. 1 " <br />DWELLING UNIT <br />705 <br />200 <br />4 <br />R-2 <br />I\ � <br />i <br />i <br />IL 1 , I 1 ❑ <br />/� HORIZONTAL EXIT AT FIRE o I °I I II <br />\\ Io I ; ii Li \� <br />m I WALL PROVIDED FOR I 1 <br />C I ACCESSIBLE MEANS OF <br />C I EGRESS ONLY PER CBC <br />1009.2.1 EXCEPTION 1 ii V 1 �--------� <br />r----------- I I <br />00 II <br />1 <br />m ---- CPET = 55'-81 <br />r-- MIS <br />TOTAL OCCUPANT LOAD = 91 <br />128 OCCUPANTS/3 EXITS =30/31 OCC. PER EXIT <br />170'-6 19/64" <br />1/3 OVERALL DIMENSION=111'-0" <br />` <br />J <br />- -- - -� <br />I o <br />0 <br />CV � <br />1 <br />❑❑ 8 <br />r------------� <br />E, <br />1 <br />18'-2 1 /2" <br />1 DEAD END CORRIDOR <br />MAX. = 50'- <br />1 <br />ETQ7'-5 7 7 <br />IT � II <br />1 <br />❑❑° L <br />LL _J <br />= <br />j <br />1 <br />1 ° El <br />1 <br />DWELLING UNIT <br />I <br />1 ❑❑ <br />1126 200 <br />6 R-2 <br />- <br />I II <br />- 1 <br />1 <br />-----= <br />1 <br />r <br />II <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />31 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4 <br />PROPOSED DOOR WIDTH <br />36" <br />1 <br />I <br />I � <br />1 <br />CPET = 54'-5" 1 <br />�------1 <br />� L <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />31 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />9.3" <br />PROPOSED STAIR WIDTH <br />48" <br />OCCUPANT LOAD SCHEDULE <br />Name Area Occ. Load Factor Occ. Load <br />REQUIRED STAIR WIDTH (CBC 1005.3.1) <br />OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) <br />REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) <br />OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS <br />AREAS CALCULATED <br />S-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 <br />R-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 <br />DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 <br />ACCESSIBLE MEANS OF EGRESS <br />1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: <br />A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) <br />B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS <br />COMPLYING WITH SECTION 1009.4. <br />OR <br />B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE <br />MEANS OF EGRESS. <br />C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. <br />EXIT PLAN NOTES <br />1. REFER TO FIRE PROTECTION NOTES. <br />1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM <br />1.2. PROVIDE FIRE ALARM SYSTEM <br />1.3. PROVIDE STANDPIPES <br />2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: <br />2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS <br />FOR SPECIFIC LOCATIONS): <br />A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. <br />B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL <br />EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: <br />i) "EXIT STAIR DOWN" <br />ii) "EXIT RAMP DOWN" <br />iii) "EXIT STAIR UP" <br />iv) "EXIT RAMP UP" <br />2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. <br />2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. <br />A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. <br />B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 <br />LUX). <br />C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. <br />D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. <br />2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL <br />INSPECTION. <br />3. PROVIDE FIRE EXTINGUISHERS: <br />3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE <br />EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON <br />EACH FLOOR. <br />3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING <br />FINAL INSPECTION. <br />4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH <br />BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE <br />ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. <br />5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. <br />6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT <br />CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. <br />7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. <br />SYMBOL LEGEND <br />E ■ � ■ E <br />3-HR FIRE WALL - SEE AD-26 <br />■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ L = XX' <br />EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL <br />DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT <br />ACCESS <br />■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ CPET = XX' <br />COMMON PATH OF EGRESS TRAVEL DISTANCE <br />IHEO <br />HORIZONTAL EXIT <br />X X o' <br />EXIT AND OCCUPANT LOAD <br />LU <br />FLOOR AREA <br /># OF OCCUPANTS <br />OCCUPANT SPACE/FUNCTION <br />OCCUPANT LOAD SF/OCCUPANT <br />OCCUPANCY TYPE <br />FIRE EXTINGUISHER CABINET MAX. <br />F.E.C. 75'-0" O.C., SEE DETAIL XX <br />xx.xx <br />STANDPIPE <br />INTERIOR EXIT STAIR <br />HORIZONTAL EXIT REFUGE AREA <br />® EXIT SIGN PER CBC SECTION 1013 <br />• <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVI S'Flkil,,N'I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />O <br />d� <br />Q <br />U <br />z <br />Q <br />Lii <br />z <br />Q <br />w <br />v! <br />w <br />LO <br />LO <br />06 <br />LO <br />No. Date Description H <br />v ) <br />U <br />U-1 <br />2 <br />U <br />Z <br />Q <br />J <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v J <br />SED ARC,S,,T <br />U- <br />P, 0 <br />N <br />* No. C29795 * <br />C) <br />RENEWAL DATE <br />CNI <br />AUGUST 31, 2023 <br />1 <br />of <br />C A� <br />License Stamp <br />o <br />BUILDING A FOURTH <br />FLOOR EXITING <br />ANALYSIS <br />BUILDING A - LEVEL 4 EXITING ANALYSIS SCALE: 3/32"=1'-01 1 <br />i <br />COPYRIGHT n <br />AO-34 <br />