My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 4:26:33 PM
Creation date
8/14/2023 7:49:24 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
23
Date
12/6/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESSORY <br />58 1 300 <br />1 1 R-2 <br />®----------------------------------------------r--------------'� I ; �-----------------------------------� -� <br />1 ®®� �■' F� ° O -� O I I 1 S r_ o o F� 0 110 <br />1 � � <br />,� fry Im Fr-1 r1 a ❑ ❑ 1 l <br />LL J I LL _J ��yy I 1 1 <br />El El <br />1 IL_ _ / -2 _ J I °1 1 Co °I10 1 � Uri\\ I I 1 <br />1 0 1 ° 1 \ 1 DWELLING UNIT1 1 <br />El N <br />1 ; 1 11 E 1 669 200 <br />j1 II <br />DWELLING UNIT ii 1 .I 1 E I 1 1 4 R-2 <br />1 rr=�� �� 705 200 1 g I 1 _ I 1 - 1 ,% �_ 1 <br />1 11 ��� 4 R-2 1I 1 1 = 1 1 = 1 1 % ��-, 1 <br />11 .. 11 rr ===�7 rr ===�7 rr = =�� <br />d II <br />1 11 II 1 - - - - - - - ii ii 1 ii ii ii ii <br />1 II II 1 11 11-� a II 11 IIF1ir <br />ME F__1 DWELLING UNIT <br />11 - - 1043 200 DWELLING UNIT 1 1 11 <br />T 1 u` 6 R-2 669 200 <br />II 1 <br />4 R-2 1 � 1 11 1 <br />- L L DWELLING ULl <br />NIT v ��� \ \w' ii LL J <br />1 1107 200 <br />6 �� 1 -- <br />II 1° ti 1 L = 218'-1i 1 = 180'-2" �� <br />0 1 <br />~----� PM M M WAIllif IM i \AL.----- <br />-- 1 L 1 1 <br />'IL J 1 <br />DWELLING UNIT ; I ; %' O\M ;OO �� N 10 \ 0 1 <br />1250 200 ' ENS N' a� � 1 /� HORIZONTAL EXIT AT FIRE �" I° 1 <br />7 G SSG M I WALL PROVIDED FOR <br />� 1 1 �p��� P�-�' �PP� -1 ACCESSIBLE MEANS OF 1 <br />DWELLING UNIT <br />705 <br />200 <br />4 <br />R-2 <br />Fill, <br />El <br />-----------13 ��EGRESS ONLY PER CBCP � ; 11 ���c > 1009.2.1 EXCEPTION 1 <br />❑❑ / 2 0� r 4 <br />:J <br />LL _J 1 II II 1 <br />II F=I]MMJ <br />II7 __1 1 0 <br />m <br />1 ii ii 1 WELL UNIT hL <br />`1 669 200 <br />I <br />t <br />- <br />----------- <br />- -7 <br />�'-/ <br />+ <br />o <br />EGRESS OPENING WIDTH <br />1 <br />YNNE/m/a, <br />1 <br />TOTAL OCCUPANTS <br />60 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />F_ 7 <br />REQUIRED OPENING WIDTH <br />12" <br />1 <br />11 <br />L <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />DWELLING UNIT <br />1126 200 <br />6 R-2 <br />C <br />PROPOSED DOOR WIDTH 36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />60 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />18" <br />PROPOSED STAIR WIDTH <br />48" <br />` <br />` <br />J <br />1 <br />0 <br />1 <br />18'-2 1 /2' <br />1 DEAD END CORRIDOR <br />MAX. - <br />50'� <br />1 <br />ETQ7'-5 <br />IT <br />1I <br />1 <br />1 <br />; <br />L_ L <br />LLJ <br />= <br />j <br />1 <br />1 ° <br />1 <br />DWELLING UNIT <br />1 <br />1 <br />❑❑ <br />1 <br />1126 200 <br />6 R-2 <br />- <br />1 <br />II <br />r 'III <br />- i <br />1 <br />J <br />1 <br />1 <br />1 f <br />1 <br />CPET = 54'-5" 1 <br />co II <br />u � <br />u <br />u <br />DWELLING UNIT <br />424 200 <br />3 R-2 <br />F__9 <br />L_ Al <br />U <br />-1 L <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />61 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />12.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />61 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />18.3" <br />PROPOSED STAIR WIDTH <br />48" <br />OCCUPANT LOAD SCHEDULE <br />Name Area Occ. Load Factor Occ. Load <br />REQUIRED STAIR WIDTH (CBC 1005.3.1) <br />OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) <br />REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 <br />OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS <br />AREAS CALCULATED <br />S-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 <br />R-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 <br />DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 <br />ACCESSIBLE MEANS OF EGRESS <br />1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: <br />A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) <br />B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS <br />COMPLYING WITH SECTION 1009.4. <br />OR <br />B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE <br />MEANS OF EGRESS. <br />C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. <br />EXIT PLAN NOTES <br />1. REFER TO FIRE PROTECTION NOTES. <br />1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM <br />1.2. PROVIDE FIRE ALARM SYSTEM <br />1.3. PROVIDE STANDPIPES <br />2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: <br />2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS <br />FOR SPECIFIC LOCATIONS): <br />A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. <br />B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL <br />EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: <br />i) "EXIT STAIR DOWN" <br />ii) "EXIT RAMP DOWN" <br />iii) "EXIT STAIR UP" <br />iv) "EXIT RAMP UP" <br />2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. <br />2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. <br />A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. <br />B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 <br />LUX). <br />C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. <br />D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. <br />2.5 ADDITIONAL EXIT SIGNS MAYBE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL <br />INSPECTION. <br />3. PROVIDE FIRE EXTINGUISHERS: <br />3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE <br />EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON <br />EACH FLOOR. <br />3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING <br />FINAL INSPECTION. <br />4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH <br />BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE <br />ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. <br />5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. <br />6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT <br />CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. <br />7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. <br />SYMBOL LEGEND <br />..............L=XX' <br />■■■■■■■■■■■ CPET=XX' <br />IHEO <br />FLOOR AREA <br /># OF OCCUPANTS <br />XXC5 <br />W <br />3-HR FIRE WALL - SEE AD-26 <br />EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL <br />DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT <br />ACCESS <br />COMMON PATH OF EGRESS TRAVEL DISTANCE <br />HORIZONTAL EXIT <br />EXIT AND OCCUPANT LOAD <br />OCCUPANT SPACE/FUNCTION <br />OCCUPANT LOAD SF/OCCUPANT <br />OCCUPANCY TYPE <br />FIRE EXTINGUISHER CABINET MAX. <br />F.E.C. 75'-0" O.C., SEE DETAIL XX <br />xx.xx <br />STANDPIPE <br />INTERIOR EXIT STAIR <br />HORIZONTAL EXIT REFUGE AREA <br />® EXIT SIGN PER CBC SECTION 1013 <br />• <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED7 OAK <br />INVES'I'MEN'I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />r <br />0 <br />N <br />d� <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />W <br />w <br />w <br />w <br />LO <br />LO <br />06 <br />LO <br />No. Date Description H <br />10 <br />m <br />v ) <br />U <br />W <br />2 <br />U <br />Z <br />Q <br />J <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v J <br />ARCy�T <br />LL <br />G��SED <br />N <br />* No. C29795 * <br />C) <br />RENEWAL DATE <br />CNI <br />AUGUST 31, 2023 <br />1 <br />9jF of <br />r <br />O <br />CA��F <br />License Stamp <br />o <br />BUILDING A SEVENTH <br />FLOOR EXITING <br />ANALYSIS <br />DWELLING UNIT <br />705 <br />200 <br />4 <br />R-2 <br />BUILDING A - LEVEL 7 EXITING ANALYSIS SCALE:3/32"=V-01 1 <br />COPYRIGHT n <br />AO-37 <br />
The URL can be used to link to this page
Your browser does not support the video tag.