Laserfiche WebLink
PLAN -UNIT 1L-01 UPPER <br />I I <br />awes,LD­­­­IWX0191- diw.A�A.M <br />2a•-o• <br />- REFERTO OVERALL PLANS FOR <br />EXTERIOR WALL CONFIGURATION <br />--------------- <br />LIVING BEDROOM <br />CLI11 <br />PLAN -UNIT 1L-01 LOWER %� <br />GENERAL NOTES <br />1. SEESHEETA3.0: UNIT KITCHEN PLANS AND UNIT BATHROOM <br />PLANS FOR ALL DETAIL DIMENSIONS AND CLEARANCES. <br />2. LIGHTS TO BE CENTERED IN CEILING AREA WITHIN ROOM <br />UNLESS NOTED OTHERWISE. <br />3. ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT <br />w p om <br />rcN�u <br />SHALL BE KEPT AS TIGHT AS POSSIBLE TO FLOORSTRUCTURE <br />4. FOR FIRE BARRIER LOCATIONS PLEASE REFER TO THE <br />COMPOSITE FLOOR PLANS. <br />r VZR <br />5, EVERY DWELLING MUST BE PROVDIED WITH SMOKE ALARM <br />a =ez <br />DEVICES PER SECTION (90].2AD)- SEE PLANS FOR LOCATION AND <br />ELECTRICAL FOR WIRING. <br />B. OPERABLE PORTION OF ANY WINDOW MUST BE X MIN AWAY <br />FROM ANY EXHAUST VEM OR DUCT. EXHAUST DUCTS SHALL <br />TERMINATE A MIN. OF 3' FROM OPENINGS INTO THE BUILDING. <br />]. ALL FIRE RATED PARTITION WALLS SHALL BE UNINTERRUPTED. <br />INTERIOR WALLS SHOULD BE OVER RATED DRYWALL. <br />8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY WINDOW/ <br />DOOR R.O. FOR TYPES AND LOCATIONS PRIOR TO INSTALLATION. <br />9. WINDOWS IN SLEEPING ROOMS MUST MEET LABC EGRESS <br />REQUIREMENTS OF 5.7 SF OF OPENING WITH 20' CLEAR OPENING IN <br />WIDTH, M" IN HEIGHT AND MAX. OF d SILL HEIGHT. IT IS THE <br />RESPONSIBILITY OF THE WINDOW SUPPLIER TO ENSURE THAT <br />p <br />5 <br />f <br />WINDOWS COMPLY WITH THIS REQUIREMENT. <br />10. APARTMENTUNITENTRY DOOR ASSEMBLIES AT CORRIDORS0 <br />SHALL BE EQUIPPED WITH GASKETS FOR SMOKE AND DRAFT <br />5 <br />3z rc8 <br />CONTROL. DOOR AND FRAME OF SUCH ASSEMBLIES SHALL BEARAN <br />APPROVED LABEL SHOWING THE RATING FOLLOW BY THE LETTER "W. <br />- <br />NAME OF THE MANUF. AND THE I.D. OF THE LISTING SERVICE, ALONG <br />WITH A PEEP HOLE. <br />11. LCCATETHESMOKEALARMA MIN. 20 FEET FROM <br />PERMANENTLY INSTALLED COOKING APPLIANCE. 2019 DEC <br />9W7.2.10.B(NFPA ]2 29.8.3.4) EXCEPTION 1-ALLOW IONVATION SMOKE <br />✓ <br />aF`vo'+aa <br />ALARMS 1C FEET OR GREATER AWAY. EXCEPTION2- ALLOWS <br />PHOTOELECTRIC SMOKE GREATER THAN 0 FEET FROM PERMANENTLY <br />INSTALLED COOKING APPLIANCE WHERE THE KITCHEN OR COOKING <br />AREA AND ADJACENT SPACES HAVE NO CLEAR INTERIOR PARTITIONS <br />AND THE 10-FOOT DISTANCES WOULD PROHIBIT THE PLACEMENT OF A <br />,^ <br />SMOKE DETECTOR REQUIRED BY OTHER SECTIONS OF THE CODE. <br />O <br />FLOOR PLAN KEY NOTES O <br />z <br />y� <br />O <br />iYMBOL <br />DESCRIPTION <br />1 <br />42" HT. BALCONY RAILING <br />2 <br />BALCONY DECK WITH WATERPROOFING <br />3 <br />MECHANICAL SHAFT <br />4 <br />DOOR BU=R MOUNTED 40" A.F.F. MAX. AND CONNECTED TO <br />PERMANENT WIRING(HARDWIRED) <br />a 4 <br />5 <br />STACKABLE FRONT LOADING WASHER AND DRYER, SELECT BY <br />OWNER. PROVIDE LOWERED DOOR. <br />8 <br />1-HR RATED PROTECTION AT INTERIOR POST/SHEAR PANEL <br />] <br />DISHWASHERUNGERCWNTERTOP <br />0 <br />30" ELEC. IGNITION GAS RANGE <br />OPENING WITH TEMPERED GLASS. SHOWER FLOOR <br />1YY' PER FT. SLOPE TO DRAIN. SEE ACCESSIBILITY NOTE <br />I UNIT PLAN CEILING KEYNOTES I <br />LEGEND <br />DOOR. SEESHEETA].1 WINDOW TYPE, SEE <br />WINDOW SCHEDULE <br />W.H. WATRHEATERWITH30" HVAC HVACFANUNIT <br />HT. BUILD OUT BOX <br />�- KITCHENIBATHROOM TYPE 1...1 GRIDLINE <br />4 — DETAIL # / SHEET# <br />INCANDESCENT LIGHTING <br />EELECTRICAL PANEL .P. 0 CEILING RECESSED <br />C.C. COMMUNICATION CONTROL BOX MOISTURE PROTECTED <br />® OETECTOWALARM-SEE INCANDESC LIGHTING <br />NOTE1 MOUNT <br />NOTE11 CEIWALL MOUNTED LIGHT <br />® DECANDON ECTMONOXIDE b WALL MOUNTED LIGHT <br />Dn <br />THERMOSTAT <br />QT THERMOSTAT D DOORBELL <br />YalNa <br />4" CEILING RECESSED Q EXHAUST FAN W/ HUMIDITY <br />­DD <br />INCANDESCENT LIGHTING SENSOR W/MIN. 50 GEM <br />G TELEVISION I CABLE OUTLET N TELEPHONE OUTLET <br />_ <br />— <br />SYMBOL <br />DESCRIPTION <br />DETAIL <br />CONCRETE WALL <br />® <br />CMU WALL <br />SHEET TITLE. <br />ENLARGED <br />® <br />3HR. RATED WALL ARTY WALL <br />IVA7.31 <br />UNIT PLANS <br />® <br />2 HR. RATED SHAFT WALL <br />]/A].31 <br />® <br />1 HR. RATED PARW WALL <br />10 /A].31 <br />1 HR. RATED CORRIDOR WALL <br />3/A7.31 <br />0 <br />INTERIOR WALL W/WOOD STUD W/ONE <br />LAYER GYP. BD. ON EACH SIDE <br />EETC <br />A5.25 <br />