Laserfiche WebLink
City tlalt, Santa Aha, Cal. <br />June ~5, 1915, at B p.m. <br /> <br />The Board met in special session, pursuant to the following call. <br /> <br />You are hereby notified to attend a special meeting of the Board of Trustees at <br />the City Hall June ESrd, 1915 at E p.~.~, to discuss a report of a com~.ittee sub- <br /> <br />mitted in relation to the Opera House. <br /> Frank <br /> <br />Present, Trustees HcPhee, Greenleaf, Grubb and <br /> <br />Absent, <br /> <br />The President of the Board of Trustees being absent Trustee Grubb was named as <br />President pro rem. <br /> <br />In Re Report of <br />Committee <br /> <br />President of the Board of Trustees, <br />the Clerk, and Alderman. <br /> <br />Santa Aha, <br />To the Hon. <br />Gentlemen~ <br />as to what <br /> <br />California, June 19, 191S, <br /> <br /> Board of Trustees, City of Santa Ana~Cal. <br /> <br />In reply to your request for an ol_inion <br /> <br />repairs are necessar~ to make the Gr~ud <br /> <br /> Opera House perfectly safe for any capacity load that <br /> may be ~ermitted in it, we wish to report as follows: <br /> After a careful examination we found that the building <br /> had been well constructed with a factor of safety of <br /> approximately E to 1, which, while providing for any <br /> ordinary test does not meet the requirements of the <br /> best factors at the present time. We therefore reco- <br /> mmend that additions be made to increase the strength to <br /> carry a live load of 150 pounds per square foot with a <br /> factor of safety of 4 to 1. To meet this requirement <br /> we suggest that the following additions be made: <br /> 1st. That the beams under the lobl0y and entrance be <br /> strengthened by the addition of four $" X 1E" E5 Sb. <br /> channels. <br /> <br /> End. That the beams suI~porting the main auditoriur~ be <br /> strengthened by the addition of 16 ~" X 1E'~ EC~ lb. <br /> channels. <br /> <br /> ~rd. That the gallery be supported by an addtional <br /> 1E" X 18" girder extending from wall to ~all; placed <br /> approximately 14 or 16 feet from the one now in pla~e; <br /> the beam to be supported on the walls at the ends and <br /> on ~ 5" iron columns resting on brick wall and l~iers, <br /> below le~ding to basement. <br /> <br /> ~th. That an additional 8 ft. exit be ~rovtded at the <br /> N.E. corner of the main auditorium, with a stairway lead- <br /> ing to th~ ground. <br /> <br /> 8th. That the fire escapes be provided at the N.M. ~d <br /> <br /> M.W. corners of the gallery leading to the stairway below. <br />8th. That all exits and f~re escapes be marked by exit <br /> <br /> signs and red lights and provided with panic bolts. <br /> <br />The following report was submitted: <br /> <br /> <br />