Laserfiche WebLink
MOBILEMOBILEMOBILEMOBILEMOBILE <br />U.C.Ref <br />r.NEW METAL STUD WALL PER SHEET A61.1 <br />EXISTING METAL STUD WALL <br />EXISTING CONCRETE WALL <br />NOT IN SCOPE <br />2-HR RATED FIRE BARRIER <br />1-HR RATED FIRE PARTITION <br />WALL TYPE ANNOTATIONS, SEE SHEET <br />A61.1 FOR DETAILS <br />1 <br />101 NUMBER INDICATES DOOR PER SCHEDULE, <br />REFER TO SHEET A52.1 <br />NUMBER INDICATED WINDOW PER SCHEDULE, <br />REFER TO SHEET A53.1 <br />FIRE EXTINGUISHER CABINET PER DET. XX/XX <br />FLOOR PLAN GENERAL NOTES: <br />1. ALL DIMENSIONS ARE TO CENTERLINE OF THE GRID LINES AND/OR TO THE <br />FACE OF STUDS, U.N.O. <br />2. UNLESS NOTED OTHERWISE, ALL WALLS ARE FULL HEIGHT. <br />3. REFER TO SHEET GEN-4 FOR TYPICAL ACCESSIBILTY REQUIREMENTS AND <br />DIMENSIONS. <br />4. REFER TO ENLARGED PLANS FOR DIMENSIONS AND CALLOUTS NOT <br />SHOWN HERE. <br />1i <br />60" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR TURNING SPACE <br />C L R . 6 0 " M I N .30"X48" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR FLOOR SPACE <br />30"X48" <br /> CLR. <br />1-HR RATED FIRE BARRIER <br />504 SF <br />CHILDRENS <br />AREA <br />5 <br />293 SF <br />TEEN <br />AREA <br />4 <br />1080 SF <br />GENERAL <br />STACKS <br />3 <br />57 SF <br />RESTROOM <br />2 <br />275 SF <br />OFFICE <br />1 <br />124000.D <br />E132 <br />124000.M124000.M124000.M124000.M <br />205 SF <br />READING <br />AREA <br />75' - 0"1' - 0"1' - 0"1' - 0"1 <br />A22.1 <br />2 <br />A22.1 <br />2' - 7"107100.B <br />107100.B <br />064100.B <br />064100.B <br />064100.B12' <br /> <br />- <br /> 1"12' - 1" <br />1 2 ' - 1 " <br />124000.P <br />124000.P <br />124000.S <br />124000.T <br />124000.U <br />124000.V <br />30X48 CLEAR <br />3' - 9" <br />064100.I <br />124000.O <br />MOBILEMOBILEMOBILEMOBILE124000.O <br />064100.K <br />4' - 9" <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS:OWNER:PROJECT NAME:CLIENT ADDRESS:6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />1/4" = 1'-0" <br />Issue Date <br />A11.6 <br />IMPROVEMENTS - <br />FURNITURE <br />PLAN <br />#2022-40198CITY OF SANTA ANADELHI COMMUNITY CENTERRENOVATION505 E Central Ave, Unit B, Santa Ana, CA 92707FLOOR PLAN LEGEND1/4" = 1'-0"1PROPOSED FURNITURE PLAN <br />064100.B WALL-MOUNTED COUNTERTOP, SEE DET. 03/A63.3 <br />064100.I ONE SIDED LIBRARY SHELVING, OFCI <br />064100.K WALL-MOUNTED COUNTERTOP, SEE DET. 05/A63.3 <br />107100.B (N) FLOOR MOUNTED DESIGNER CLEAR SECURITY GATE <br />LIB-180 RFID SCANNER, SEE SPECS FOR TYPE/SIZE, OFOI <br />124000.D 4 TOP CIRCULAR TABLE AND CHAIRS, TYP., OFOI <br />124000.M NEW RIVELI MODULAR FOLDING SHELVING SYSTEM, OFCI <br />124000.O MOBILE BOOK CARTS, OFOI <br />124000.P CHILDERENS FURNITURE, TYP., OFOI <br />124000.S 8 TOP WORKING TABLE WITH INDIVIDUAL SEAT DIVIDERS, <br />FLUSH MOUNTED POWER PROVIDED, OFOI <br />124000.T WORKSTATIONS, OFOI <br />124000.U MOBILE BOOK CARTS, OFOI <br />124000.V BOOK DROPOFF COLLECTION BIN, OFOI <br />E132 INKJET PRINTER, OFOI <br />KEYNOTES <br />DESCRIPTION DATE <br />N <br />  <br />  <br />City Council 17 – 16 9/17/2024