Laserfiche WebLink
FUTUREREFER RACK,A/C LINES ANDCONTROLLINES FORRESTAURANT(2) FUTUREGREASESHAFTSCORRVENTSHAFTELEV A1ELEV A2IDFRWCORRIDORVENTILATIONSHAFTIDFCORRIDORVENTILATIONSHAFTPOOL RESTROOMEXHAUST SHAFTSPFECLVELECLVELEC <br />ELEC <br />LV <br />ELEC LVLVELECELECLV <br />ELECLVLVELECLVELECLV <br />ELEC LVELECLVELECLVELEC <br />LVELECLVELECLVELEC3.23.4455.16788.8910BAC.1CDEFGHKG.9G.74.38.93185'-4"16'-4"31'-6"28'-6"31'-6"30'-0"31'-6"16'-0"1'-3"3'-1"12'-0"2'-9"1'-3"1'-6"2'-8"123'-4"13'-3"30'-0"13'-6"2'-0"13'-4"30'-2"12'-0"4'-4"3'-4"2'-4"4'-10"J2'-9"6.1C.6E.52'-0"4'-0"16'-3"10'-2"27'-3"1'-4"30'-2"28'-9"C.25"1"G.10TURN-AROUNDSPOTUP 5%164.64'164.64'165.13'165.13'165.13'165.13'165.13'164.64'164.64'165.13'164.88'164.64'159.06'159.06'159.06'159.06'160.63'160.63'160.63'160.63'159.06'159.06'160.63'160.63'160.23'158.59'167.70'167.70'164.39'UP 5%DOWN 5%FEC <br />DOWN 1.6%ñññ <br />ñññ ññññ <br />ñ <br />ñEVEVEVEVSTAIR A4STAIR A3LVELECUPDNDNLV <br />ELECLVELECLV <br />ELEC <br />FECFECDNDOWN 4.5% <br />FEC <br />165.12'164.64'164.64'DNUPSPUNIT 0.3CA501A5-03UNIT 4.1C-RA502A5-42UNIT 2.1CA503A5-21UNIT 2.1F-RA504A5-22UNIT 4.1HA506A5-43UNIT 4.1KA518A5-43UNIT 0.1B-RA505A5-01UNIT 1.2BA507A5-13UNIT 1.1D-RA508A5-12UNIT 2.4BA509A5-28UNIT 2.2EA510A5-24UNIT 1.2B-RA511A5-13UNIT 2.5BA517A5-29UNIT 1.2BA515A5-13UNIT 0.1DA516A5-01UNIT 2.6AA519A5-35UNIT 2.2C-RA520A5-24UNIT 1.1B-RA512A5-11UNIT 1.1CA513A5-11UNIT 2.1G-RA514A5-221'-0"18'-4"2"AIRSPACE53'-0"2"AIRSPACE37'-6"1'-0"10'-3"2"AIRSPACE16'-1 1/2"2"AIRSPACE25'-0"18'-4"53'-2"2" <br />AIRSPACE <br />9'-6 1/4"2" <br />AIRSPACE <br />35'-10"1'-4 3/4"36'-0"36'-0"2" <br />AIRSPACE <br />53'-2"9" <br />110'-4 1/2"242'-6"34'-6"2"AIRSPACE37'-6"91'-9 1/2"37'-6"2"AIRSPACE33'-0"7'-10 1/2"4A5-744A5-764A5-723A5-9034'-6"2" <br />AIRSPACE <br />11'-3"2" <br />AIRSPACE <br />24'-6"6'-11"2"24'-11"2'-1"9'-9"2"AIRSPACE36'-0"2"AIRSPACE23'-10"6"23'-10"2"AIRSPACE7'-9 1/2"9'-9 1/2"2"22'-0 1/2"2"4'-9 1/2"8'-0"22'-2"0"4'-10"6'-6"25'-0"6'-7"25'-0"34'-2"2" <br />AIRSPACE <br />23'-10"2" <br />AIRSPACE <br />11'-5"6'-2"6'-5 1/2"2"25'-8"1'-4"7'-10"2"24'-0"1'-0"7'-3 1/2"1'-0"2"8'-0"6'-8 1/2"1'-5"9"1'-2 1/2"2"9'-10"91'-9 1/2"5"6'-8 1/2"1'-3"2"1 3/8"10'-7"5'-1"2"2'-3"2"5'-7"A501A502A503A504A505A506A507A508A509A510A511A512A513A518A515A516A517BBBB19'-5"5'-10"2'-0"1'-0"A5144AD-2618'-0" TYP.9'-0"3'-0"9'-0"9'-0"9'-0"3'-0"9'-0"9'-0"7'-9"18'-0"9'-0"3'-0"9'-0"9'-0"9'-0"1'-6"18'-0" <br />18'-0"2'-11"9'-0"9'-0"9'-0"3'-0"9'-0"9'-0"9'-0"11'-11"9'-0"9'-0"3'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"1'-6"18'-0" <br />1'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"6'-10"3'-0"1A2-212A2-201A2-202A2-211A2-222A2-223A2-22AA2-40BA2-40EA2-42DA2-41CA2-41FA2-42GA2-431A5-963A2-31HA2-4355A2-32A2-3222A2-30A2-3066A2-32A2-3244A2-31A2-3111A2-30A2-30MA2-45LA2-451A5-951114R-2, 1129 S.F.R-2, 1222 S.F.R-2, 1344 S.F.R-2, 1197 S.F.R-2, 439 S.F.R-2, 786 S.F.R-2, 1164 S.F.R-2, 775 S.F.R-2, 773 S.F.R-2, 786 S.F.R-2, 786 S.F.R-2, 1342 S.F.R-2, 441 S.F.R-2, 934 S.F.R-2, 1216 S.F.R-2, 775 S.F.R-2, 1166 S.F.R-2, 1164 S.F.R-2, 1356 S.F.R-2, 520 S.F.PARKINGS-2, 11185 S.F.(TYP. L2-L5)2-HR(TYP. L3-L5)IDFP504R-2, 14 S.F.IDFP511A5-90R-2, 22 S.F.ELECTRICALMETERSP519R-2, 37 S.F.CHUTEACCESS ROOMP518A5-94R-2, 154 S.F.IDFP520R-2, 31 S.F.RESTAURANTUTILITYP521R-2, 15 S.F.4AD-25ADOUBLE 2-HR FIRE WALLIN LIEU OF 3-HR FIREWALL PER NFPA 22148"23'-0"MIN. DRIVE AISLE WIDTH17RAMP A14CORRIDORR-2, 4280 S.F.R-29 S.F.37 S.F.R-2R-241S.F.5665204'-6"6'-2" <br />7"3'-4"6'-0"6'-0"3'-4"CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA06-21-23ADDENDUM ABUILDING A FIFTHLEVEL FLOOR PLANA2-15BUILDING COMPOSITE PLAN NOTES6AD-311.THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS,ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TOTHE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION.2.UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THELEGAL ADDRESS.3.FOR GENERAL ACCESSIBILITY INFORMATION, SEE4.ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O.5.OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O.6.PROVIDE PENETRATION FIRESTOP SYSTEMS PER7.THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY8.WITH CBC 803.9.INTERIOR TRIMS SHALL COMPLY WITH CBC 806.10.PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING,PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATEDACCESS PANELS WITH SELF CLOSING DEVICES.11.PROVIDE ACOUSTICAL ASSEMBLIES PER12.INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806.13.MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER14.VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2.15.SEE STRUCTURAL DRAWINGS FOR:A)SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHINGB)SPECIAL NAILING AND BLOCKING REQUIREMENTS15.PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIORBALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROMIRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNINGPERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BEVENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLERPROTECTION SHALL BE EXTENDED TO THOSE AREAS.16.WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW ORIRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALLELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTEDAND APPROVED.17.PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTIONTHROUGHOUT.18.VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%)19.FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPEPROTECTION PER20.GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FORSUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC.21.THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FORSECURITY AND SAFETY.22.ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROMDRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS.23.SEE SHEETS A0-11 THRU A0-25 FOR ALL WALL FIRE RATINGS AND CORRESPONDING DETAILS24.SEE SHEETS A0-31 THRU A0-45 FOR EXITING ANALYSIS INCLUDING ROOM NAME, SQUARE FOOTAGE,OCCUPANT LOAD FACTOR, NUMBER OF OCCUPANTS AND OCCUPANCY TYPE25.CEILING FIXTURES THAT ARE RECESSED INTO FLOOR/CEILING ASSEMBLIES SHALL BE PROTECTED VIA LINEDJOIST BAY PER DETAIL 6/AD-21.26.PROVIDE CONTINUOUS DRYWALL BEHIND TUBS PER DETAIL 20/AD-22.27.CONTINUOUS DRYWALL IS REQUIRED BEHIND ALL ELECTRICAL SERVICE PANELS, FIRE HOSES AND MEDICINECABINETS PER DETAIL 4/AD-22.28.FOR TYPICAL CORRIDOR SECTION INCLUDING NOTES AND DETAILS, SEE29.INTERIOR FLOOR FINISHES SHALL SHOW COMPLIANCE WITH CBC SECTION 804.4AD-20ALLAD-02.1 ALLAD-01TOKEYNOTESMECHANICAL SHAFT - SEE MECHANICAL DRAWINGSLINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF,SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITHLOCAL FIRE AUTHORITY.BUILDING PLAN LEGENDDOOR SYMBOLFLOOR DRAIN - SEE PLMBXXWINDOW & STOREFRONT SYMBOL -A7-20-A7-404AD-22FECDOWNSPOUTDSFDDIRECTION OF SLOPE - 1/4" / FT U.N.O.ALLAD-2018AD-2212-A7-10-A7-30ACCESSIBLE PARKING SPACEALLAD-32ALLAD-41.1WATERPROOF TRAFFIC COATINGFRAMED WALL - 6" METAL STUDCONCRETE COLUMNMAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROMACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEARAFF IN ALL OTHER LOCATIONS OF GARAGE.FULL HEIGHT STEEL FENCING-X"DEPRESSIONSLOPE TO LEVELLEVEL TO SLOPEDEPRESSION TO SLOPE-X"16AD-3140" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEFRAMED WALL - 3-5/8" METAL STUDAIRCRAFT CABLE VEHICULAR BARRIERSPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O.SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS-3" FSFS = FINISH SURFACETOC = TOP OF STRUCTURAL CONCRETE SLABTO CURB = TOP OF CURB-6" TOC19AD-31CONCRETE WHEEL STOPDETECTABLE WARNINGS, MIN 36" WIDECONCRETE TOPPING SLAB(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.)COLUMN CAPCMU WALL - SEE STRUCTURALFRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURBCONCRETE WALL - SEE STRUCTURALCONCRETE STRUCTURAL SLAB TRANSITIONSRETAIL PARKING SPACE3GUEST PARKING SPACE4EV READY SPACE (FUTURE)5EV CHARGING SPACE (INSTALLED)6CLEAN AIR VEHICLE PARKING SPACE742" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-318ACCESSIBLE PARKING SPACE - MAX 2% SLOPE9VEHICULAR HEADROOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOORB. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR103AD-3112AD-31DIAGONAL STRIPING, REFER TO DETAIL 6/AD-011112AD-01EXPANSION JOINT, REFER TO SHEET AD-3312STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITIONWALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OFCONCRETE SLAB ABOVE.13DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB14EVELECTRIC VEHICLE CHARGING STATIONSEE SCHEDULESSEE DOOR SCHEDULESALLAD-55ALLAD-56PROVIDE SIGNAGE & BRAILLE ADJACENT TO DOORS LEADING INTO PARKING GARAGEAS A MEANS OF PROVIDING DETECTABLE WARNINGS PER DETAIL15EXTENT OF EXTERIOR STUCCO FINISH1AD-31.11AD-31.11AD-31.15AD-31.12AD-31.13 & 4AD-31.15,6 & 9AD-0121AD-718 & 12AD-27ROOM NUMBER */ UNIT NUMBERROOM NAME / UNIT TYPEXX001A5-XXSHEET REFERENCE* ROOM NUMBERS BEGINNING WITH 'P'HAVE BEEN ASSIGNED BY ARCHITECTFOR PROJECT COMMUNICATION. THESEROOM NUMBERS ARE NOT PART OF THEADDRESSING SYSTEM.REFER TO SHEET A5-87 FOR ENLARGED RAMP PLANS A2 THROUGH A716REFER TO SHEET A5-88 FOR ENLARGED RAMP PLANS A8 THROUGH A1417REFER TO SHEET A5-89 FOR ENLARGED RAMP PLANS B1 THROUGH B5182-HR RATED ACCESS PANEL, 18" (W) X 24" (H)19A2-HR RATED ERRCS SHAFT WITH 90 MIN. ACCESS PANEL, 12" (W) X 12" (H)20STORM WATER DETENSION BASIN, SEE CIVIL DRAWINGS21AGATE AND FENCE2220AD-52.1SCALE:13/32"=1'-0"BUILDING A FIFTH LEVEL FLOOR PLAN NAAAATYP. ATEXTERIORPOSTAAAAAAAA06-21-23