ELEC <br />LV32'-0"18'-0"32'-0"18'-0"U1aU4aU6bU5aJKJ12'-1"19'-11" <br />11"3'-3"10'-10 1/2"4'-10 1/2"2'-0"9'-10 1/2"5'-11 1/2"VERIFY2'-10"3'-3 1/2"3'-9"2"1'-6"22'-4"8'-2" <br />7'-7"4'-0"7'-4"3'-5"10"6'-2"3'-8 1/4"5'-1 3/4"4'-0"7'-4"4'-11"5'-6 1/2"3'-5 1/2"3'-5 1/2"5'-6 1/2"3.2LIVINGVINYLBATHVINYL*3.13.33.43.54.24.33.71.52.12.2KITCHENVINYLCLOSETVINYLLAUNDRYVINYLNAT. LIGHTING & VENT. CALC.ROOM AREA: 266 SFAREA REQUIRED: LIGHT (8%) = 22 SFVENT. (4%) = 11 SFAREA PROVIDED: LIGHT = 31.5 SFVENT. = 18 SF*REFER TO NOTE 18 FOR ADDITIONAL INFO4.41'-9 1/2"2.32.32'-0"1'-2"1ST FLOOR: 8'-8"UPPER FLOORS: 7'-8"1ST FLOOR: 10'-0"UPPER FLOORS: 9'-0"1ST FLOOR: 9'-0"UPPER FLOORS: 8'-0"1ST FLOOR: 9'-0"UPPER FLOORS: 8'-0"BATHABCD4.43.54.24.33.74.5KITCHEND3'-0"1'-6"3'-2"3.23.13.33.43.32.12.22.3WORK STATIONB2'-6"1.31'-6"3'-8"3'-8"3'-8"2'-1"2'-7"1'-6"3'-3"3'-0"3.9A3.9A3.9A1'-0"54x44 <br />48x48 1'-6"54x421'-6"1'-6"54x4236x4236x422.32.3MIN. 48" CLEARMIN. 36" <br />CLEAR MIN. 36"CLEAR18" CLR.MIN. 24"CLEAR2'-0"1'-10"UNIT 0.2 PLANS ANDINTERIOR ELEVATIONSA5-02SCALE:11/4"=1'-0"UNIT 0.2ACCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM AUNIT PLAN KEYNOTESCOAT CLOSET : (S & P) SHELF AND POLE MOUNTED @ 70" AFF60"x32" FIBERGLASS TUB / SHOWER W/ 72" HIGH FIBERGLASS WAINSCOT. PROVIDE INTEGRAL REINFORCINGFOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND CURTAIN ROD.18" WIDE TOWEL BAR @ 40" A.F.F.1.ALL DIMENSIONS ARE TO THE FACE OF FRAMING (STRL SHT'G / FURRING STRIPS, AS OCCURS, OR OPEN STUDS)U.N.O.2.ALL DWELLING UNITS SHALL BE ADAPTABLE AND ON AN ACCESSIBLE ROUTE. FOR GENERALDWELLING UNIT ACCESSIBILITY INFORMATION, REFER TO3.EXTEND FLOORING UNDER SINKS AND LAVATORIES WITH REMOVABLE CABINET AND BASE. FINISH ENDWALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE, PRIME & PAINT EXPOSED GYP. BOARD.WALL TO MATCH WALLS. INSTALL MATCHING BASE BOARD.4.FOR RECESSED FIXTURES AND EQUIPMENT INSTALLED IN A RATED WALL REFER TO DETAIL5.PROVIDE BACKING FOR ALL ACCESSORIES, HANDRAILS, GRAB BARS AND WINDOW COVERINGS.6.MAINTAIN RATED FLOOR CONSTRUCTION AT PLUMBING CUTOUTS FOR TUBS IN WOOD FRAMED FLOORS.7.OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, U.N.O.8.KITCHEN SINK TO HAVE REAR-SET GARBAGE DISPOSAL WITH AIR-GAP FOR DISHWASHER - SEE PLUMBING PLANSFOR FIXTURE SPECS.9.CONTINUE DRYWALL TO NEAREST CORNER TO ALIGN FACE OF FINISH.10.FOR SHOWER PAN AND FLOOR / CEILING ASSEMBLY, REFER TO DETAIL11.NO RANGE HOOD VENTS, DRYER VENTS, COMBUSTION VENTS, OR HEATING VENTS AREPERMITTED IN FIRE WALLS.12.CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHTGRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NOGREATER THAN 5 POUNDS.13.ALL KITCHEN FLOORING SHALL CONTINUE TO BACK WALLS OF REFRIGERATOR AND RANGE ALCOVES.14.VERIFY ALL APPLIANCE, FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO FABRICATION ANDINSTALLATION.15.VERIFY MANUFACTURER'S AND U.L. APPROVED CLEARANCES BETWEEN SELECTED APPLIANCES ANDCOMBUSTIBLE MATERIALS.16.RECESSED CABINETS (MEDICINE, LAUNDRY PLUMBING, ELECTRIC PANELS, ICE MAKER BOX, ETC.) OCCURRING INFIRE-RATED WALLS SHALL BE INSTALLED TO MAINTAIN THE REQUIRED FIRE RATING.17.SUBMIT CABINET, COUNTERTOP AND CABINET HARDWARE SAMPLES TO OWNER FOR REVIEW AND APPROVAL.18.FOR NATURAL LIGHT AND VENTILATION CALCULATIONS, CASEMENT WINDOWS ARE ASSUMED TO PROVIDE 70%VISIBLE LIGHT AND 60% OPEN FOR VENTILATION, AND SLIDING WINDOWS ARE ASSUMED TO PROVIDE 75% VISIBLELIGHT AND 40% OPEN FOR VENTILATION, AND FRENCH DOORS ARE ASSUMED TO PROVIDE 50% VISIBLE LIGHT AND90% OPEN FOR VENTILATION.RECESSED ELECTRICAL SUB-PANEL, HIGHEST OPERABLE PART AT 48"MAX. ABOVE FLOOR - SEE ELECTRICAL DRAWINGS FOR MOREINFORMATION-AD-034AD-22FINISH CARPENTRY: MDF SHELF AND WOOD POLES U.N.O. CONFIRM SHELF HEIGHTS WITH OWNERLINEN SHELVES : 5 SHELVES EQUALLY SPACEDMINIMUM 30" WIDE WORK SURFACE WITH KNEE AND TOE CLEARANCES PER 6/AD-04.BEDROOM CLOSET SHELVING: SEE PLAN FOR MORE INFORMATION-(S & P) - SINGLE SHELF AND POLE @ 70" AFF-(DS & DP) - DOUBLE SHELF AND DOUBLE POLE @ 42" & 84" AFF-(SS) - SHELF STACK: 5 SHELVES EQUALLY SPACEDLINEN AT BATH: 3 SHELVES @ 40", 56" & 72"24" WIDE TOWEL BAR @ 40" A.F.F.MANUFACTURED CABINETRY: ALL EXPOSED FACES TO HAVE MATCHING FINISH-A7-00-A7-30RECESSED LOW VOLTAGE SUB-PANEL - SEE ELECTRICAL DRAWINGS FORMORE INFORMATIONELECTRICAL RISER STUD BAY REQ'D ADJACENT TO SUB-PANEL WHENOCCURS IN 2x4 FRAMED WALL.DESIGNATED BATH SHALL COMPLY WITH CBC SECTION 1134A.2 OPTION 2ITEMS 1 - 12. NOTE: ALL OTHER BATHROOMS IN THE SAME UNIT SHALLCOMPLY WITH OPTION 2 ITEMS 8 - 12.*LVELECFLOORING MATERIAL TRANSITION, PROVIDE TRANSITION STRIPREQUIRED ACCESSIBLE CLEAR FLOOR SPACE PER CBC CH. 11A1.1XXXXUNIT PLAN NOTESUNIT PLAN LEGEND1.21.31.41.560"x30" CLEAR ACCESSIBLE FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. PROVIDE REINFORCINGFOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND TEMPEREDGLASS ENCLOSURE.2.13.13.23.33.43.5LAVATORY: SINGLE LEVER FAUCET. TOP LIP OF SINK AT 34" MAX. REMOVABLE BASE CABINETS.PROVIDE FINISH FLOORING BELOW REMOVABLE BASE CABINETS. INSULATE & PROTECT WATER &WASTE LINES.3.63.74.1TOILET PAPER HOLDER @ 19" A.F.F.RECESSED MEDICINE CABINETDOOR REFERENCEWINDOW REFERENCELOW WALL (SEE PLAN FOR HEIGHT)2X4 WALL (1-1/2"x3-1/2" METAL STUD AT TYPE 1A UNITS, 2X4 FIRE-RETARDANTTREATED WOOD STUD AT ALL OTHER LOCATIONS)2X6 WALL (1-1/2"x5-1/2" METAL STUD AT TYPE 1A UNITS, 2X6 FIRE-RETARDANTTREATED WOOD STUD AT ALL OTHER LOCATIONS)1-1/2"x2-1/2" FURRED METAL STUD WALLF.M.C.FIXTURES & APPLIANCES4.24.34.44.5BASE CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION2.2UPPER CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION2.318" WIDE BREADBOARDS HAVE BEEN PROVIDED IN LIEU OF THE 30" WIDE WORK SURFACE PER1134A.4 EXCEPTION.2.4FULL HEIGHT PANTRY CABINETDOUBLE BASIN SINK W/ GARBAGE DISPOSAL. PROVIDE SHALLOW SINK W/ REAR DRAIN TO ALLOW FOR KNEE &TOE CLEARANCE. GC TO CONFIRM SINK WITH DISPOSAL INSTALLED WILL MEET KNEE & TOE CLEARANCE PER16/AD-03. PROVIDE MIN. 30" OF COUNTERTOP FOR SINK INSTALLATION, REMOVABLE BASE CABINETS, SINGLELEVER FAUCET AND INSULATE / PROTECT SUPPLY & WASTE LINES. PROVIDE FINISH FLOORING BENEATHREMOVABLE BASE CABINETS24" WIDE DISHWASHER30" WIDE SLIDE-IN ELECTRIC RANGE W/ 30" WIDE MICROWAVE / HOOD ABOVE W/ LIGHT & FAN TOVENT TO EXTERIORREFRIGERATORMIRRORACCESSORIESUNIT RCP NOTES6AD-2110AD-2110AD-211.REFER TO MECHANICAL DRAWINGS FOR INFORMATION REGARDING SUPPLY & RETURN AIRREGISTERS, EXHAUST FANS AND OTHER HVAC EQUIPMENT.2.REFER TO ELECTRICAL DRAWINGS FOR INFORMATION REGARDING LIGHT FIXTURES, SMOKEDETECTORS, SWITCHES, ELECTRICAL CEILING BOXES AND THE LIKE.3.CEILING HEIGHTS INDICATED ARE APPROXIMATE MEASURED BETWEEN FINISHED SURFACES.6.APPLY 5/8" TYPE "X" GYP BOARD ON STUD WALLS EXTENDING IN TO SOFFITS PRIOR TO SOFFITINSTALLATION.10.PROVIDE CEILING FINISHED WITH MAXIMUM FLAME SPREAD RATING REQUIRED BY CBC.11.ALL GYP. BOARD INSTALLED PRELIMINARILY AND/OR PRIOR TO PRIOR TO TYPICALCONSTRUCTION SEQUENCING SHALL BE WEATHER RESISTANT AND NON-PAPER FACED.12.WHERE OCCURS, INSTALL RECESSED LIGHTING IN RATED FLOOR/CEILING ASSEMBLIES PERDETAIL13.WHERE OCCURS, INSTALL DUCTWORK IN RATED FLOOR/CEILING ASSEMBLIES PER DETAILPENDANT / HANGING LIGHT FIXTURESURFACE MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHTACCESS PANELDIFFUSER / FAN - SEE MECHANICAL FOR MORE INFORMATIONCEILING FANJUNCTION BOXJRECESSED LIGHT FIXTURECEILING HEIGHTUNIT RCP PLAN LEGENDSOFFIT, SEE PLANS FOR CEILING HEIGHTGYPSUM BOARD LINED JOIST BAY9'-0"42"x42" FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. TEMPERED GLASS ENCLOSURE.3.810AD-21SOFFIT ABOVE CABINETS (7'-8" CLR. A.F.F. U.N.O)A. PROVIDE GRAB BAR BACKING IN WALL FOR FUTURE GRAB BAR INSTALLATION AT TOILET,BATHTUB, AND SHOWER.B. PROVIDE GRAB BAR BACKING IN WALL FOR FUTURE FOLD DOWN GRAB BAR INSTALLATION AT TOILET.3.96,10AD-032.5OPEN SHELVES ABOVE SINK2.64" HIGH BACKSPLASH6,7,14,15AD-8414AD-8416AD-039AD-03ELECTRICAL CONVENIENCE OUTLET IN FACE OF BASE CABINET FILLER PANEL OR INPONY WALL, PENINSULA AT LOCATIONS SHOWN, REQUIRED TO ACHIEVE ACCESSIBLEREACH RANGES4.0ACONCRETE ON LEVEL 1. CONCRETE TOPPING OVER DEPRESSED FRAMING AT UPPER LEVELSA4.01PONY WALLGENERAL4.022-HR FIRE RATED EXTERIOR DECK/PATIO POST5AD-55.1S7S8S9HANDRAIL - 34" MIN TO 38" MAX ABOVE TREAD NOSING PER CBC 1012.2. MAX. 4.5"PROJECTION INTO REQURED WIDTH PER CBC 1012.8.GUARD - 42" MIN HIGH RAILING w/ OPENINGS SPACED SO A 4" SPHERE CANNOT PASSTHROUGHSLIP-RESISTANT WARNING STRIPE AT TOP APPROACH AND BOTTOM TREADSTAIRAS19CAST-IN-PLACECONCRETE STAIRSCALE:31/4"=1'-0"UNIT 0.2 REFLECTED CEILING PLANSCALE:41/4"=1'-0"UNIT 0.2 INTERIOR ELEVATIONSSCALE:21/4"=1'-0"UNIT 0.2 ACCESSIBILITY PLANAAAAAAAAAAA06-21-23