|
UPFEC4CIT2-9
<br />9
<br />TENANT
<br />2
<br />PARCEL 2PARCELAT 15"AFF4CIT2-
<br />9
<br />TENAN
<br />2
<br />PARCSPTSRQPNMLK8.68.74'-5"8'-9"4'-7"17'-11 1/4"22'-4"21'-6"8'-1"9'-0"1'-0"Q.1M.410'-10"9.69.710.210.31111.211.511.71218'-2 1/4"2'-2 3/4"5'-1"2'-0 1/2"14'-1"3'-7"12'-0"7'-0"4'-5"R.5Q.211 1/2"10 1/4"1'-6"16'-3 1/2"R.O.16'-0"6'-11"2'-1 1/2"7'-6"4'-3 1/2"7'-6"5'-0"9'-0"11'-0"
<br />5 1/2"
<br />1'-0"1'-0"2'-6"1'-6 1/2"1'-0"1'-3"1'-3"3'-8"7 1/2"8'-0 1/2"1'-9"4'-11 1/2"16'-11"4'-6"1'-6"10'-0"2'-7"6'-6"17'-1 3/4"8'-4 1/4"2'-5"11'-3"4'-10 1/2"3'-9 7/8"15'-8"1'-8 1/8"1'-6 1/2"2'-10 1/2"1'-0 1/2"4'-1 1/2"13'-8 3/4"6'-1"20'-0 1/2"3'-8 7/8"1'-5"4'-1 1/2"
<br />1'-0"13'-6 1/2"3'-3 1/4"5'-8"28'-5 3/4"8 1/4"8'-6 1/4"4'-4 1/2"6"5'-2 7/8"1'-3 1/8"9'-10 1/2"9"8'-3"11'-6 1/2"6'-9"2'-7 1/2"7'-2 1/4"17'-2 1/2"2'-10 1/2"5'-7 1/2"17'-2 1/2"7'-10"16'-2 3/4"7 1/2"2 1/2"9'-5"2'-6"1'-0"1'-4"2"1'-0"10'-2 1/2"2'-10 1/4"
<br />11 1/2"CENTERLINE OF STEEL 6'-1 1/2"5'-0"5'-0"5'-0"
<br />5'-0
<br />"
<br />5'-0"5'-0"5'-0"5'-0"34" COUNTER HEIGHT30x48CLEAR19" DCLEAR30x48CLEAR19" DCLEAR34" COUNTERHEIGHT34" COUNTERHEIGHT34" COUNTERHEIGHT34" COUNTERHEIGHT34" COUNTERHEIGHT1A6-01ABCD30x48CLEAR19" DCLEAR30x48CLEAR19" DCLEAR30x48CLEAR19" DCLEAR
<br />CORRIDORVENTILATIONSHAFT
<br />STAIR A316 &22AD-712'-1"MIN17'-5"19 EQ. TREADS @ 11" EACHUP2-14AD-71.13'-10"
<br />STAIR WIDTHS9S8S7 ELEV A2ELEV. 1NOTE: PRIMARY EXTERIORENTRIES SHALL BE COVERED TOPREVENT WATER INTRUSION BYUSING NONABSORBENT FLOORAND WALL FINISHES WITHIN ATLEAST 2 FEET AROUND ANDPERPENDICULAR TO SUCHOPENINGS4A6-01A4'-0"4'-0"
<br />4'-0"4'-0"22'-6 1/2"25% MAX. OPENING = 5'-7 1/2"5'-6"15'-1"25% MAX OPENING = 3'-9 1/4"2A5-571A5-57A1A2CO-WORKINGP110A5-54B, 2351 S.F.OFFICEP109A5-54B, 150 S.F.WORK PODP112A5-54B, 80 S.F.CONFERENCEP113A5-54B, 268 S.F.OFFICEP111A5-54B, 181 S.F.L1 LEASING, L1 FITNESS &L2 YOGA RESTROOMP114A5-54B, 121 S.F.WORK PODP115A5-54B, 89 S.F.WORK PODP116A5-54FITNESSP119A5-54B, 1567 S.F.FITNESS CLOSETP118A5-54B, 34 S.F.B, 89 S.F.1'-10 1/4"
<br />2'-3"4'-2"6'-10 3/8"7'-9 1/8"G7G2G3R1R8R3R2R61'-9"6'-0"1'-7 1/4"123.21'123.16'123.72'123.72'123.16'3.6%DNDN7.1%2AD-02.1G5G1R115"17'-1 3/4"1'-1 1/2"ROLL-DOWN FIRE DOOR INCASE OF FIRE. THIS IS NOTPART OF THE EGRESSSYSTEM. SEE COMPOSITEAND EXITING PLAN FORMORE INFORMATIONG2CLOSETP120A5-54B, 23 S.F.1A2-303'-11"1'-0"1'-6"10'-2 1/2"10'-1"1ST FL T.O.SLAB ON GRADE6'-8"
<br />HEAD CLEARANCE
<br />2ND FL SUBFLOOR11'-2 1/2"± RISE VERIFY
<br />21 EQ 6.71" RISERS13AD-71.114AD-71.1CLOSETFITNESSS8S3CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
<br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM ALEASING & AMENITYENLARGED PLAN -LEVEL 1A5-54BUILDING COMPOSITE PLAN NOTES6AD-311.THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS,ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TOTHE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION.2.UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THELEGAL ADDRESS.3.FOR GENERAL ACCESSIBILITY INFORMATION, SEE4.ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O.5.OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O.6.PROVIDE PENETRATION FIRESTOP SYSTEMS PER7.THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY8.WITH CBC 803.9.INTERIOR TRIMS SHALL COMPLY WITH CBC 806.10.PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING,PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATEDACCESS PANELS WITH SELF CLOSING DEVICES.11.PROVIDE ACOUSTICAL ASSEMBLIES PER12.INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806.13.MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER14.VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2.15.SEE STRUCTURAL DRAWINGS FOR:A)SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHINGB)SPECIAL NAILING AND BLOCKING REQUIREMENTS15.PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIORBALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROMIRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNINGPERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BEVENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLERPROTECTION SHALL BE EXTENDED TO THOSE AREAS.16.WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW ORIRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALLELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTEDAND APPROVED.17.PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTIONTHROUGHOUT.18.VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%)19.FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPEPROTECTION PER20.GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FORSUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC.21.THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FORSECURITY AND SAFETY.22.ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROMDRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS.23.SEE SHEETS A0-11 THRU A0-25 FOR ALL WALL FIRE RATINGS AND CORRESPONDING DETAILS24.SEE SHEETS A0-31 THRU A0-45 FOR EXITING ANALYSIS INCLUDING ROOM NAME, SQUARE FOOTAGE,OCCUPANT LOAD FACTOR, NUMBER OF OCCUPANTS AND OCCUPANCY TYPE25.CEILING FIXTURES THAT ARE RECESSED INTO FLOOR/CEILING ASSEMBLIES SHALL BE PROTECTED VIA LINEDJOIST BAY PER DETAIL 6/AD-21.26.PROVIDE CONTINUOUS DRYWALL BEHIND TUBS PER DETAIL 20/AD-22.27.CONTINUOUS DRYWALL IS REQUIRED BEHIND ALL ELECTRICAL SERVICE PANELS, FIRE HOSES AND MEDICINECABINETS PER DETAIL 4/AD-22.28.FOR TYPICAL CORRIDOR SECTION INCLUDING NOTES AND DETAILS, SEE29.INTERIOR FLOOR FINISHES SHALL SHOW COMPLIANCE WITH CBC SECTION 804.4AD-20ALLAD-02.1 ALLAD-01TOKEYNOTESMECHANICAL SHAFT - SEE MECHANICAL DRAWINGSLINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF,SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITHLOCAL FIRE AUTHORITY.BUILDING PLAN LEGENDDOOR SYMBOLFLOOR DRAIN - SEE PLMBXXWINDOW & STOREFRONT SYMBOL -A7-20-A7-404AD-22FECDOWNSPOUTDSFDDIRECTION OF SLOPE - 1/4" / FT U.N.O.ALLAD-2018AD-2212-A7-10-A7-30ACCESSIBLE PARKING SPACEALLAD-32ALLAD-41.1WATERPROOF TRAFFIC COATINGFRAMED WALL - 6" METAL STUDCONCRETE COLUMNMAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROMACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEARAFF IN ALL OTHER LOCATIONS OF GARAGE.FULL HEIGHT STEEL FENCING-X"DEPRESSIONSLOPE TO LEVELLEVEL TO SLOPEDEPRESSION TO SLOPE-X"16AD-3140" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEFRAMED WALL - 3-5/8" METAL STUDAIRCRAFT CABLE VEHICULAR BARRIERSPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O.SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS-3" FSFS = FINISH SURFACETOC = TOP OF STRUCTURAL CONCRETE SLABTO CURB = TOP OF CURB-6" TOC19AD-31CONCRETE WHEEL STOPDETECTABLE WARNINGS, MIN 36" WIDECONCRETE TOPPING SLAB(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.)COLUMN CAPCMU WALL - SEE STRUCTURALFRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURBCONCRETE WALL - SEE STRUCTURALCONCRETE STRUCTURAL SLAB TRANSITIONSRETAIL PARKING SPACE3GUEST PARKING SPACE4EV READY SPACE (FUTURE)5EV CHARGING SPACE (INSTALLED)6CLEAN AIR VEHICLE PARKING SPACE742" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-318ACCESSIBLE PARKING SPACE - MAX 2% SLOPE9VEHICULAR HEADROOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOORB. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR103AD-3112AD-31DIAGONAL STRIPING, REFER TO DETAIL 6/AD-011112AD-01EXPANSION JOINT, REFER TO SHEET AD-3312STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITIONWALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OFCONCRETE SLAB ABOVE.13DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB14EVELECTRIC VEHICLE CHARGING STATIONSEE SCHEDULESSEE DOOR SCHEDULESALLAD-55ALLAD-56PROVIDE SIGNAGE & BRAILLE ADJACENT TO DOORS LEADING INTO PARKING GARAGEAS A MEANS OF PROVIDING DETECTABLE WARNINGS PER DETAIL15EXTENT OF EXTERIOR STUCCO FINISH1AD-31.11AD-31.11AD-31.15AD-31.12AD-31.13 & 4AD-31.15,6 & 9AD-0121AD-718 & 12AD-27ROOM NUMBER */ UNIT NUMBERROOM NAME / UNIT TYPEXX001A5-XXSHEET REFERENCE* ROOM NUMBERS BEGINNING WITH 'P'HAVE BEEN ASSIGNED BY ARCHITECTFOR PROJECT COMMUNICATION. THESEROOM NUMBERS ARE NOT PART OF THEADDRESSING SYSTEM.REFER TO SHEET A5-87 FOR ENLARGED RAMP PLANS A2 THROUGH A716REFER TO SHEET A5-88 FOR ENLARGED RAMP PLANS A8 THROUGH A1417REFER TO SHEET A5-89 FOR ENLARGED RAMP PLANS B1 THROUGH B5182-HR RATED ACCESS PANEL, 18" (W) X 24" (H)19A2-HR RATED ERRCS SHAFT WITH 90 MIN. ACCESS PANEL, 12" (W) X 12" (H)20STORM WATER DETENSION BASIN, SEE CIVIL DRAWINGS21AGATE AND FENCE2220AD-52.1SCALE:13/16"=1'-0"LEASING AND AMENITY - LEVEL 1SCALE:23/16"=1'-0"FITNESS STAIR SECTION1.FOR TYPICAL STAIR DETAILS, REFER TO2.TREADS: ALL TREAD SURFACES SHALL BE SLIP RESISTANT. TREADS SHALL HAVE SMOOTH,ROUNDED OR CHAMFERED EXPOSED EDGES AND NO ABRUPT EDGES AT THE NOSING.3.TREAD AND RISER DIMENSIONAL UNIFORMITY: STAIR TREADS AND RISERS SHALL BE OFUNIFORM SIZE AND SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISERHEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED0.375 INCH IN ANY FLIGHT OF STAIRS.4.TREAD PROFILE: THE RADIUS OF THE LEADING EDGE OF THE TREAD SHALL BE NOTGREATER THAN 0.5 INCH. BEVELING OF NOSING SHALL NOT EXCEED 0.5 INCH. RISERS SHALLBE SOLID AND VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE LEADING EDGE OF THETREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES FROM THE VERTICAL. THELEADING EDGE (NOSING) OF TREADS SHALL PROJECT NOT MORE THAN 1.25 INCHESBEYOND THE TREAD BELOW AND ALL PROJECTIONS OF THE LEADING EDGES SHALL BE OFUNIFORM SIZE, INCLUDING THE LEADING EDGE OF THE FLOOR AT THE TOP OF A FLIGHT.5.HANDRAIL CONTINUITY: HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUTINTERRUPTION BY NEWEL POSTS OR OTHER OBSTRUCTIONS.6.HANDRAIL EXTENSIONS: HANDRAILS SHALL RETURN TO THE WALL, GUARD OR THE WALKINGSURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. ATSTAIRWAYS WHERE HANDRAILS ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILSSHALL EXTEND AT LEAST 12 INCHES BEYOND THE TOP RISER AND 12 INCHES, PLUS THETREAD WIDTH, BEYOND THE BOTTOM RISER. WHERE THE STAIRS ARE CONTINUOUS FROMLANDING TO LANDING, THE INNER RAIL SHALL BE CONTINUOUS AND NEED NOT EXTEND OUTINTO THE LANDING.7.EXIT ENCLOSURE PENETRATIONS: PENETRATIONS INTO AND OPENINGS THROUGH AN EXITENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT DOORS, SPRINKLER PIPING,STANDPIPES, ELECTRICAL RACEWAY(S) FOR FIRE DEPARTMENT COMMUNICATION SYSTEMSAND ELECTRICAL RACEWAY(S) SERVING THE EXIT ENCLOSURE. THERE SHALL BE NOPENETRATIONS OR COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, BETWEENADJACENT EXIT ENCLOSURES.8.STRIPING FOR THE VISUALLY IMPAIRED: INTERIOR EXIT STAIRWAYS SHALL HAVE THE UPPERAPPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST.EXTERIOR EXIT STAIRWAYS SHALL HAVE STRIPES ON THE UPPER APPROACH AND ON ALLTREADS. THE STRIPE SHALL BE A MINIMUM OF 2 INCHES WIDE TO A MAXIMUM OF 4 INCHESWIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH FROM, THE NOSE OF THE STEPOR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP ORUPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP-RESISTANT ASTHE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE.9.ALL DIMENSIONS ARE TO THE FACE OF STUD, CMU OR CONCRETE AS OCCURS, U.N.O.STANDPIPESTAIR NOTESLEGEND-AD-71STAIR KEYNOTESS1S2S3S4S5S6S7S8S9S10S11S12S13S14S15S16S17S18S19S20S21S2221AD-7117AD-7118AD-71HANDRAIL - 34" MIN TO 38" MAX ABOVE TREAD NOSING PER CBC 1012.2. MAX. 4.5"PROJECTION INTO REQURED WIDTH PER CBC 1012.8.GUARD - 42" MIN HIGH RAILING w/ OPENINGS SPACED SO A 4" SPHERE CANNOT PASSTHROUGHGUARDWALL - 42" MIN HIGHSECURITY SCREEN SYSTEM- 1" STEEL BAR TOP AND BOTTOM RAILS WITH 1/4" PICKETS AT 4"O.C.- MOUNT TO FLOOR SLAB OR STAIR STRINGERS- PROVIDE 1/4" SQ. , 9 GAUGE WIRE MESH ASNOTED ON PLANBARRIER GUARDRAIL - 27" H, BELOW STAIRSLIP-RESISTANT WARNING STRIPE AT TOP APPROACH AND BOTTOM TREADSTAIRWAY IDENTIFICATION SIGNTACTILE FLOOR DESIGNATION SIGNTACTILE EXIT SIGNSTANDPIPE - CLASS IALTERNATING TREAD DEVICESTAIR LANDING : STAIR CONSTRUCTIONPLYWOOD TREAD AND RISER2X WOOD STRINGER - REFER TO STRUCTURAL PLANSWOOD FRAMED LANDING - REFER TO STRUCTURAL PLANSCAST-IN-PLACE CONCRETE STAIRDASHED ARC INDICATING 44" CLEAR PATH ABOUT STAIR / HANDRAIL, PER CBC 1011.2KNOX BOX - SEE BUILDING PLANSMETAL STAIR GATE BARRIER - PER CBC 1023.823AD-71STEEL CHANNEL STRINGER1-PIECE SLIP RESISTANT PRE-CAST CONC TREAD AND RISERS20aDASHED ARC INDICATING 48" CLEAR PATH ABOUT STAIR / HANDRAIL, PER CBC 1011.2NYSTROM ROOF HATCH WITH INTEGRAL OSHA COMPLIANT ALUMINUM SAFETY RAILS (POWDERCOATSAFETY YELLOW) - SEE STAIR ROOF LEVEL FOR OPENING SIZES23PER CBC SEC. 1011.6 THE DOOR AT ANY POSITION SHALL NOT REDUCE THE REQUIRED STAIRLANDING DIMENSION TO LESS THAN ONE-HALF ITS REQUIRED WIDTH. - CLEAR SPACE IS SHOWN ONPLAN WITH DASHED ARC.-AD-71.130" x48" CLEAR FLOOR AREA5'-0" DIAMETER TURN AROUND SPACEENLARGED PLAN REFERENCES1.FOR WALL FIRE-RATINGS AND DETAIL REFERENCES, FIRE EXTINGUISHERLOCATIONS AND FIRE ACCESS ANALYSIS, SEE SHEETS A0-11 THRU A0-25 .2.FOR EXITING ANALYSIS INCLUDING OCCUPANT LOADS, EXIT SIGNS AND DOOR PANICHARDWARE LOCATIONS, SEE SHEETS A0-31 THRU A0-45.EXTENT OF EXTERIOR CEMENT PLASTER FINISHDIAGONAL HATCH INDICATES EXTENT OF EXTERIOR PLASTER SOFFIT ORDROPPED GYP. BD. CEILING BELOW RATED FLOOR/CEILING ASSEMBLY. SOFFITHEIGHT AS INDICATED IN PLAN. EXTERIOR CEMENT PLASTER OVER EXTRUDEDMETAL LATH OCCURS AT LOBBIES WITH EXTERIOR WALL OPENINGS. SEEENLARGED PLANS FOR EXTENT.CMU WALL - SEE STRUCTURALCONCRETE WALL - SEE STRUCTURAL18AD-61.1S24SIGN INDICATING DOOR AS A DETECTABLE WARNING2X4 WALL (1-1/2"x3-1/2" METAL STUD AT TYPE 1A CONSTRUCTION, 2X4FIRE-RETARDANT TREATED WOOD STUD AT ALL OTHER LOCATIONS)2X6 WALL (1-1/2"x5-1/2" METAL STUD AT TYPE 1A CONSTRUCTION, 2X6FIRE-RETARDANT TREATED WOOD STUD AT ALL OTHER LOCATIONS)NOTE: REQUIRED PLUMBING FIXTURES FOR LEVEL 1 A-3 CO-WORKING SPACE ARE LOCATED ON LEVEL 2. REFER TO A5-55 FOR MORE INFORMATION.PLUMBING FIXTURES REQUIREMENTS FOR BUSINESS OCCUPANCY (B) (CPC 2019 TABLE 422.1) LEVEL 1 LEASING & LEVELS 1&2 FITNESSTotal area(in S.F.)Number of occupants (50%)(200 load factor)Number of drinking fountainsService sinkNumber of toilets (women)Number of toilets (men)Number of urinalsNumber of lavatories (women)Number of lavatories (men)2,84481111111NOTE: IN BUSINESS AND MERCANTILE OCCUPANCIES WITH 50 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED IN OCCUPANCIES WITH 10 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED*SINGLE USER RESTROOM PROVIDED ON LEVEL 1.RESTROOMSWALL MOUNTED GRAB BAR; SEE DET 10&13/AD-02, PROVIDE SOLID 2X BACKINGGENERALBOBRICK B-3571 OR EQUIV PARTITION MOUNTED SEAT COVER, SANITARYNAPKIN DISPOSAL, AND TOILET TISSUE DISPENSERR1R2R11NOTE: FOR REQUIRED RESTROOM CLEARANCES REFER TO DETAIL AD-02BOBRICK B-3947 OR EQUIV. RECESSED CONVERTIBLE PAPER TOWEL DISPENSER R3AND WASTE RECEPTACLEWAINSCOTR4R5R6TOILET - ELONGATED BOWLG1FLOOR DRAINBOBRICK OR EQUIV. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE AND SEATCOVER DISPENSERR12R8FLOOR MOUNTED OVERHEAD BRACED STANDARD LAMINATE TOILET PARTITIONR13WALL MOUNTED URINALG2MIRROR ABOVE LAVATORY WITH BOTTOM EDGE OF REFLECTING SURFACE AT 40"A.F.F. MAX.G330" X 48" REQUIRED ACCESSIBLE CLEAR FLOOR SPACE60" DIA. REQUIRED ACCESSIBLE CLEAR FLOOR SPACE.WOMEN'S RESTROOMSMEN'S RESTROOMSR9R7TOILET - ELONGATED BOWL - FLUSH HANDLE ON OPEN SIDE (MIN. 17" AND 19" MAX.SEAT HEIGHT - CENTER LINE OF TOILET SHALL BE MIN 17" AND MAX 18" FROMFINISHED SIDE WALL)KEYNOTESWALL MOUNTED ELECTRIC HAND DRYERG4STEEL FRAMED CANOPYHIGH AND LOW COMBINATION DRINKING FOUNTAIN. PROVIDE MIN. 27" CLEARBELOW BASIN. REFER COMMON AREA ACCESSIBILITY DETAILSG5G6MOP SINKG7WALL MOUNTED BABY CHANGING STATIONRESTROOM DOOR SIGNAGE PER 18/AD-02A1SIGNAGERESTROOM SIGNAGE PER 11/AD-02A21AD-84UNDERCOUNTER MOUNTED LAVATORY WITHSOLID SURFACE COUNTERTOP12AD-02A2AD-02.1G8HATCHED AREA INDICATES LOWERED SOFFIT. REFER TO REFLECTED CEILING PLANON A5-61.AREFER TO A2-11 FORSTOREFRONT AND DOORCALL-OUTSAA06-21-23
|