Laserfiche WebLink
"DDDESPFEC <br />SP2"10"2'-3 1/4"6"10'-1"3'-7"2"3 1/2"8'-0"1'-0"2"3'-1 1/4"11'-5 3/4"6'-8"6"5'-2 1/2"7"3'-7"4'-0"5'-6"3'-11"1'-0 1/2"1'-0"3'-10"27'-4"10"5'-9 1/2"4'-3 1/2"3 1/2"2'-7 3/4"3'-7 3/4"1'-6"2'-4"2'-5"9'-5"14'-9 1/2"1'-6 1/2"4'-7 1/2"5'-5 1/2"3 1/2"8'-6"4'-11 1/2"2"1'-6"4'-9" <br />6'-0 1/2" <br />1'-8"2'-6 1/2"11"1"5'-11 1/2"6 1/2"3'-8"3'-8"6 1/2"7'-10 1/2"5 1/2"3'-1 1/2"10"7 1/2"X.2X.1Y.1Y.2Y.3Y.4Y.5Y.6Y.8Y.7Y.2Y.3Y.5Y.6Y.7Y.1Y.4Y.81'-3 1/4"5'-11 1/2"8'-5"5'-5 1/2"6"2'-5 1/4"1'-7 1/4"6"7'-10 1/4"6'-5 1/2"24'-7"4"2"K2'-1"1'-0"5'-8 1/2" <br />6 1/2"60'-0"2"32'-0"2'-5 1/4"60'-0"23'-3 1/2"1'-0"6'-5 1/2"1'-0"8"25'-2"2"4'-11 1/2" <br />1'-2 1/2" <br />32'-4"X.2X.11" <br />2"ELECTRICAL METERS2'-8 1/4"2'-4"3'-8"6'-0"3'-4"5'-11 1/2"1'-2 3/4"K5.58.55.58.510'-0"23'-3 1/2"10'-0"5"6 <br />0 <br />" <br />6 <br />0 <br />"60"60"G3G1G3G3R1R2A1R11R9R11R8R7R8R13R7R14R1R6R5R5G4G4G1R2G5G68'-9 1/2" <br />8'-5 1/2" <br />11"5 1/2"1"G734" HIGH BUILT-INCOUNTER W/ FFE CHAIRSFAUX TREE AT CENTER5'-0 <br />"30x48CLEAR19" DCLEAR30x48 <br />CLEAR <br />19" D <br />CLEAR <br />30x48CLEAR19" DCLEAR <br />34" COUNTERHEIGHT30x48 <br />CLEAR <br />19" DCLEAR <br />30x48CLEAR19" DCLEAR30x48CLEAR19" DCLEAR30x48 <br />CLEAR <br />19" D <br />CLEAR2A6-02ABCD3A6-02ABCD4A6-02ABCDCLUBROOMP315A5-60AMEN'S RESTROOMWOMEN'SRESTROOMPOOL SHOWERPOOLSHOWER1A5-631'-2 3/4"3'-0"6 1/4"6A6-02A6A6-02ABCDKITCHEN ISLANDP2P3P4A1A2G7A2NON-BEARING WOODFURRED WALL WITH GYP.BD. FINISH, TYP.NON-BEARING WOODFURRED WALL WITH GYP.BD. FINISH, TYP.THRESHOLDS IN ROLL-IN TYPE SHOWERS SHALL BE 1/2"HIGH MAX. CHANGES IN LEVEL UP TO 1/4" MAY BE VERTICALAND WITHOUT EDGE TREATMENT. CHANGES IN LEVELBETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPENO GREATER THAN ONE UNIT VERT. IN 2 UNITS HORIZ.24"CLR.A-3, 1869 S.F.WOMEN'SRESTROOMP314A5-60AR-2, 305 S.F.MEN'SRESTROOMP313A5-60AR-2, 231 S.F.G22AD-02.1SINKP312A5-60AR-2, 11 S.F.2A5-63G8G8G8G8G8G830x48 <br />CLEAR <br />19" D <br />CLEAR2'-2 1/2"G3G1R12R6R1216'-2" <br />18" MIN. <br />24" MAX. <br />3'-2 1/2"3'-4"CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM ACLUBROOMENLARGED PLAN -LEVEL 3A5-60AFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF,SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITHLOCAL FIRE AUTHORITY.BUILDING PLAN LEGENDDOOR SYMBOLFLOOR DRAIN - SEE PLMBXXWINDOW & STOREFRONT SYMBOL -A7-20-A7-404AD-22FECDOWNSPOUTDSFDDIRECTION OF SLOPE - 1/4" / FT U.N.O.-A7-10-A7-30ACCESSIBLE PARKING SPACEALLAD-32ALLAD-41.1WATERPROOF TRAFFIC COATINGFRAMED WALL - 6" METAL STUDCONCRETE COLUMNMAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROMACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEARAFF IN ALL OTHER LOCATIONS OF GARAGE.FULL HEIGHT STEEL FENCING-X"DEPRESSIONSLOPE TO LEVELLEVEL TO SLOPEDEPRESSION TO SLOPE-X"16AD-3140" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEFRAMED WALL - 3-5/8" METAL STUDAIRCRAFT CABLE VEHICULAR BARRIERSPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O.SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS-3" FSFS = FINISH SURFACETOC = TOP OF STRUCTURAL CONCRETE SLABTO CURB = TOP OF CURB-6" TOC19AD-31CONCRETE WHEEL STOPDETECTABLE WARNINGS, MIN 36" WIDECONCRETE TOPPING SLAB(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.)COLUMN CAPCMU WALL - SEE STRUCTURALFRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURBCONCRETE WALL - SEE STRUCTURALCONCRETE STRUCTURAL SLAB TRANSITIONS3AD-3112AD-3112AD-01EVELECTRIC VEHICLE CHARGING STATIONSEE SCHEDULESSEE DOOR SCHEDULESALLAD-55ALLAD-56EXTENT OF EXTERIOR STUCCO FINISHROOM NUMBER */ UNIT NUMBERROOM NAME / UNIT TYPEXX001A5-XXSHEET REFERENCE* ROOM NUMBERS BEGINNING WITH 'P'HAVE BEEN ASSIGNED BY ARCHITECTFOR PROJECT COMMUNICATION. THESEROOM NUMBERS ARE NOT PART OF THEADDRESSING SYSTEM.SCALE:11/4"=1'-0"CLUBROOM - LEVEL 3RESTROOMSWALL MOUNTED GRAB BAR; SEE DET 10&13/AD-02, PROVIDE SOLID 2X BACKINGGENERALBOBRICK B-3571 OR EQUIV PARTITION MOUNTED SEAT COVER, SANITARYNAPKIN DISPOSAL, AND TOILET TISSUE DISPENSERR1R2R11NOTE: FOR REQUIRED RESTROOM CLEARANCES REFER TO DETAIL AD-02BOBRICK B-3947 OR EQUIV. RECESSED CONVERTIBLE PAPER TOWEL DISPENSER R3AND WASTE RECEPTACLEWAINSCOTR4R5R6TOILET - ELONGATED BOWLG1FLOOR DRAINBOBRICK OR EQUIV. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE AND SEATCOVER DISPENSERR12R8FLOOR MOUNTED OVERHEAD BRACED STANDARD LAMINATE TOILET PARTITIONR14WALL MOUNTED 36"X48" STANDARD LAMINATE URINAL SCREENR13WALL MOUNTED URINALG2MIRROR ABOVE LAVATORY WITH BOTTOM EDGE OF REFLECTING SURFACE AT 40"A.F.F. MAX.G330" X 48" REQUIRED ACCESSIBLE CLEAR FLOOR SPACE60" DIA. REQUIRED ACCESSIBLE CLEAR FLOOR SPACE.WOMEN'S RESTROOMSMEN'S RESTROOMSR9R7TOILET - ELONGATED BOWL - FLUSH HANDLE ON OPEN SIDE (MIN. 17" AND 19" MAX.SEAT HEIGHT - CENTER LINE OF TOILET SHALL BE MIN 17" AND MAX 18" FROMFINISHED SIDE WALL)KEYNOTESWALL MOUNTED ELECTRIC HAND DRYERG4STEEL FRAMED CANOPYHIGH AND LOW COMBINATION DRINKING FOUNTAIN. PROVIDE MIN. 27" CLEARBELOW BASIN. REFER COMMON AREA ACCESSIBILITY DETAILSG5G6MOP SINKG7WALL MOUNTED BABY CHANGING STATIONNON-ACCESSIBLE SHOWER WITH SINGLE-HAND LEVER CONTROLS ANDSTANDARD SHOWER HEADP1POOL SHOWERSFOLDING SEAT PER 1127A.5.3.7 - SEE 16/AD-02P2WATER CONTROLS AND SHOWER SPRAY UNIT PER 1127A.5.3.6 - SEE DETAIL16/AD-02P3GRAB BARS PER 1127A.5.3.8P4RESTROOM DOOR SIGNAGE PER 18/AD-02A1SIGNAGERESTROOM SIGNAGE PER 11/AD-02A21AD-84UNDERCOUNTER MOUNTED LAVATORY WITHSOLID SURFACE COUNTERTOP12AD-02A2AD-02.1G8HATCHED AREA INDICATES LOWERED SOFFIT. REFER TO REFLECTED CEILING PLANON A5-61.APLUMBING FIXTURES REQUIREMENTS FOR COMBINED OCCUPANCY - BLDG A LEVEL 3 POOL DECK & CLUBROOM (CPC 2019 SECTION 422.1)Occupancy groupTotal area(in S.F.)Number of occupants (50%)Number of drinking fountainsService sink*Pool ShowersNumber of toilets (women)Number of toilets (men)Number of urinalsNumber of lavatories (women)Number of lavatories (men)A-34,975830.331NA2.490.830.830.830.42Pool/Spa1,277860.34NA1.720.720.570.570.540.5443Total11242221NOTE: IN BUSINESS AND MERCANTILE OCCUPANCIES WITH 50 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED IN OCCUPANCIES WITH 10 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED * IN COMBINED OCCUPANCY FACILITIES, MIN. ONE SERVICE SINK SHALL BE PROVIDED*MULTI-USER RESTROOM PROVIDED ON LEVEL 3.AA06-21-23