10" MIN
<br />34- 44"
<br />38-40"
<br />44" MAX
<br />44" MAX
<br />60" MAXFIN FLRSMOOTHDOORBOTTOMBOTTOM OF CLOSERHIGH VIEWPORT **PUSH BUTTON *LOWVIEWPORTHARDWARET.O.DEADBOLTKICK PLATE MAY OCCUR 16 GA MAX, ANYCAVITIES CREATED SHALL BE CAPPED48" MAX
<br />42" PREFERED
<br />78" MIN
<br />PREFERRED TYPICAL LOCATION OF DOOR AND GATE ELEMENTS IF THEY OCCURSEE DOOR STYLES FOR SPECIFIC DOOR ELEVATION3 & 4A-5104 & 6A-520FOR ADDITIONAL INFORMATION SEE DETAILS* REQUIRED AT ACCESSIBLE/ADAPTABLE DWELLING UNITS** IF PROVIDED INSTALL TWO VIEWPORTS ONE HIGH ONELOW ATACCESSIBLE/ADAPTABLE DWELLING UNITS **NO PROJECTIONS INTOCLEAR OPENING BELOW 34"XAD-XXXAD-XXXAD-XXXAD-XXXAD-XXXAD-XXXAD-XXXAD-XX1-HR2-HRXAD-XXTEMPGLTEMPGLAENTRY DOORBINTERIOR DOORTEMPGLCFRENCH DOORDLOUVERED DOOREBY-PASS DOORFBI-FOLD DOOR10"
<br />10"
<br />10"
<br />10"DWELLING UNIT DOORSCHEDULEA7-00DWELLING UNIT DOORSXXREVISIONS
<br />DOOR NO.
<br />STYLE
<br />WIDTH
<br />HEIGHT
<br />THICKNESS
<br />MATERIAL
<br />FINISH
<br />MATERIAL
<br />FINISH DOORFRAMEREMARKSASSEMBLY FIRE
<br />RATING (MINUTES)FOR DETAILS- SEE "DOOR STYLES" & "TYPICAL DOOR DETAILS"U1aU2aU3aCCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
<br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA06-21-23ADDENDUM ATYPICAL DOOR OPENINGSDOOR STYLESTYPICAL DOOR ELEMENTSDOOR SCHEDULEA3'-0"7'-0"1 3/4"SCSGWOODSG20UNIT ENTRY DOORC3'-0"8'-0"1 3/4"SCSGWOODSG-PATIO DOOR, TEMPERED GLAZING W/ MINIMUM STC OF 28, DEAD BOLT, MAX. 0.45 U VALUE, MAX.0.23 SHGC VALUE, FIRE RATING 90 MINUTES WHEN OCCURS IN 2-HR EXTERIOR BEARING WALL,DOOR STOPB3'-0"6'-8"1 3/8"HCSGWOODSG-BEDROOM, PRIVACY LOCKU4aB3'-0"6'-8"1 3/8"HCSGWOODSG-BATHROOM, PRIVACY LOCKU5aB3'-0"6'-8"1 3/8"HCSGWOODSG-CLOSET, PASSAGE HARDWAREU6aD3'-0"6'-8"1 3/8"HCSGWOODSG-WASHER/DRYER CLOSET, PASSAGE HARDWAREU6bD2'-8"6'-8"1 3/8"HCSGWOODSG-WASHER/DRYER CLOSET, PASSAGE HARDWAREU7aB3'-0"6'-8"1 3/8"HCSGWOODSG-COAT CLOSET, PASSAGE HARDWAREU7bB2'-10"6'-8"1 3/8"HCSGWOODSG-COAT CLOSET, PASSAGE HARDWAREU7cB2'-8"6'-8"1 3/8"HCSGWOODSG-COAT CLOSET, PASSAGE HARDWAREU8aE9'-0"6'-8"1 3/8"HCSGWOODSG-BY-PASS, 3 PANELSU8bE8'-0"6'-8"1 3/8"HCSGWOODSG-BY-PASSU8cE7'-0"6'-8"1 3/8"HCSGWOODSG-U8dE6'-0"6'-8"1 3/8"HCSGWOODSG-U8eE5'-0"6'-8"1 3/8"HCSGWOODSG-U8fE4'-0"6'-8"1 3/8"HCSGWOODSG-BY-PASSBY-PASSBY-PASSBY-PASSU2bC3'-0"8'-0"1 3/4"SCSGWOODSG-PATIO DOOR, TEMPERED GLAZING W/ MINIMUM STC OF 28, INOPERABLE, MAX. 0.45 U VALUE,MAX. 0.23 SHGC VALUE, FIRE RATING 90 MINUTES WHEN OCCURS IN 2-HR EXTERIOR BEARINGWALL, DOOR STOPA. PUBLIC USE & COMMON USE AREA DOORS AND GATESCBC CHAP 10, 11A DIV III AND 11B DIV IVGATES SHALL COMPLY WITH THESE NOTES AS REQUIRED FOR DOORS.OPENING CLEARANCE1.ALL ENTRANCE AND EXIT DOORS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THEDOOR OPEN 90 DEGREES FROM ITS CLOSED POSITION, MEASURED BETWEEN THE FACE OF THE DOORAND THE OPPOSITE STOP. (1008.1.1, 11B-404.2.3, 1126A.1.1)2.FOR ACCESSIBLE DOOR CLEARANCES REQUIREMENTS, SEEEFFORT3.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR PUBLIC EXTERIORDOORS, 8 ½ POUNDS FOR COMMON AREA EXTERIOR DOORS, 5 POUNDS FOR INTERIOR DOORS, AND 15POUNDS FOR FIRE DOORS. (1008.1.3, 1126A.4, 11B-404.2.9)HARDWARE4.DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES THE DOORWILL TAKE AT LEAST 3 SECONDS TO MOVE TO APPOINT 3 INCHES FROM THE LATCH. (1126A.4.1,11B-404.2.8.1)THRESHOLDS5.THRESHOLD - LANDINGS SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE TOP OF THETHRESHOLD OF THE DOORWAY. CHANGES IN HEIGHT BETWEEN ¼ AND ½ INCH SHALL BE BEVELED ATA MAXIMUM 50%. CHANGES IN LEVEL GREATER THAN ½ INCH SHALL BE RAMPED. (1008.1.7, 1126A.2.1,11B-404.2.5)B. DWELLING UNIT DOORSPRIMARY ENTRANCE DOOR INTO AND DOORS WITHIN INDIVIDUAL DWELLING UNITS6.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 ½ POUNDS FOR EXTERIOR DOORS, 5POUNDS FOR INTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS.7.DOORS FROM INDIVIDUAL DWELLING OR SLEEPING UNITS IN GROUP R OCCUPANCIES HAVING ANOCCUPANT LOAD OF 10 OR LESS ARE PERMITTED TO HAVE A NIGHT LATCH, DEAD BOLT OR SECURITYCHAIN PROVIDED SUCH DEVICES ARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY ORTOOL (1008.1.9.3.4) AND ARE OPERABLE WITH A SINGLE EFFORT OF THE DOOR LEVER. (1132A.8)8.DOOR BUZZER, BELL, CHIME OR EQUIVALENT SHALL BE PROVIDED AT EVERY PRIMARY ENTRANCEDOOR. (1132A.10)9.THRESHOLD - SECONDARY EXTERIOR DOORS OF DWELLING UNITS SHALL BE NO HIGHER THAN ¾ INCHFOR SLIDING DOORS OR ½” FOR OTHER DOORS. CHANGES IN HEIGHT BETWEEN ¼ AND 3/4 INCH SHALLBE BEVELED AT A MAXIMUM 50%. (1008.1.7, 1132A.4.1)10.ENTRANCE DOORS FROM INTERIOR CORRIDORS TOGETHER WITH THEIR PERIMETER SEALS SHALLHAVE A LABORATORY STC RATING OF NOT LESS THAN 26. SUCH TESTED DOORS SHALL OPERATENORMALLY WITH COMMERCIALLY AVAILABLE SEALS UNLESS OTHERWISE REQUIRED BY ANACOUSTICAL REPORT. (1207.7) DWELLING UNIT EXTERIOR DOORS CONTAINING GLAZING SHALL HAVEAN STC RATING OF NOT LESS THAN 28 IN ACCORDANCE WITH THE ACOUSTICAL REPORT.COMMON AREA DOORS11.DOORS ON AN ACCESSIBLE ROUTE SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPEHARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDEPASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP, TIGHT PINCHING OR TWISTING OF THE WRISTTO OPERATE THE OPENING HARDWARE12.LEVER-TYPE HARDWARE SHALL BE CURVED WITH A RETURN TO WITHIN ½ INCH OF THE DOOR EXCEPTIN GROUP R AND U OCCUPANCIES WITH AN OCCUPANT LOAD OF 10 OR LESS.13.HARDWARE SHALL BE INSTALLED BETWEEN 34 MINIMUM TO 44 INCHES MAXIMUM ABOVE FINISHEDFLOOR.14.EGRESS DOORS IN PAIRS, APPROVED AUTOMATIC FLUSH BOLTS SHALL BE PERMITTED PROVIDEDTHAT THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS HAS NO DOORKNOB OR SURFACEMOUNTED HARDWARE.15.EGRESS DOORS - MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED.16.FIRE DOORS AND BOTH LEAVES OF PAIRS OF SIDE HINGED SWINGING FIRE DOORS SHALL BEPROVIDED WITH AN ACTIVE LATCH BOLT THAT WILL SECURE THE DOOR WHEN IT IS CLOSED.17.FIRE DOORS SHALL BE SELF-CLOSING OR AUTOMATIC CLOSING. AUTOMATIC-CLOSING FIRE DOORSASSEMBLIES SHALL BE SELF-CLOSING IN ACCORDANCE WITH NFPA 8018.SMOKE ACTIVATED DOORS - AUTOMATIC CLOSING DOORS SHALL CLOSE BY THE ACTUATION OF SMOKEDETECTORS IN ACCORDANCE WITH SECTION 907.3 OR BY LOSS OF POWER.19.INSTALL DOOR HARDWARE IN COMPLIANCE WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.20.PROTECT ALL THRESHOLDS COMPONENTS FROM DIRECT CONTACT WITH DISSIMILAR METALS ANDCORROSIVE MATERIALS PER MANUFACTURER'S RECOMMENDATIONS.21.DOORS ON AN ACCESSIBLE ROUTE: THE BOTTOM 10 INCHES MINIMUM OF ALL DOORS AND OR GATESSHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR OR GATE TO BE OPENED BYA WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.22.GLAZING IN DOORS SHALL COMPLY WITH SAFETY GLAZING (2406) RATINGS23.FIRE DOOR ASSEMBLIES THAT ARE SIDE HINGED OR PIVOTED SWINGING SHALL BE TESTED INACCORDANCE WITH NFPA 252 OR UL 10C.24.FIRE DOOR ASSEMBLIES WITH OTHER TYPES OF DOORS INCLUDING SWINGING ELEVATOR DOORS ANDFIRE SHUTTER ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL10B25.FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE PROTECTION RATING OF 20 MINUTESWHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLS HAVING A FIRE RESISTANCE RATING INACCORDANCE WITH TABLE 715.4 SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL 10CWITHOUT THE HOSE STREAM TEST.26.SMOKE AND DRAFT CONTROL - FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIREPROTECTION RATING OF 20 MINUTES WHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLSSHALL MEET THE REQUIREMENTS FOR SMOKE AND DRAFT CONTROL DOOR ASSEMBLIES TESTED INACCORDANCE WITH UL 178427.GLAZING IN DOOR ASSEMBLY - IN 20 MINUTE FIRE DOOR ASSEMBLY, THE GLAZING MATERIAL IN THEDOOR ITSELF SHALL HAVE A MINIMUM FIRE-PROTECTION-RATED-GLAZING OF 20 MINUTES.28.FIRE DOOR ASSEMBLIES IN EXIT ENCLOSURES AND EXIT PASSAGE WAYS SHALL HAVE A MAXIMUMTRANSMITTED TEMPERATURE END POINT OF NOT MORE THAN 450 F DEGREES. THIS IS NOT REQUIREDWHEN BUILDING IS EQUIPPED THROUGHOUT WITH AN NFPA 13 AUTOMATIC SPRINKLER SYSTEM.29.DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH, SHALL BE PERMITTED WHERE A ¾ HOURFIRE PROTECTION RATING OR LESS IS REQUIRED. WHERE A FIRE PROTECTION RATING EXCEEDING ¾HOUR IS REQUIRED FIRE DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH SHALL BEINSTALLED WITH FIRE-RESISTANCE-RATED GLAZING TESTED AS AN ASSEMBLY IN ACCORDANCE WITHASTM E119 OR UL 263.30.DOORS THAT ARE PART OF A FIRE RATED WALL ASSEMBLY SHALL COMPLY WITH OPENINGPROTECTIVES.31.SMOKE CONTAINMENT DOOR AT ELEVATOR OPENING - THE FIRE RATED ELEVATOR DOOR BYELEVATOR MANUFACTURER UTILIZED IN CONJUNCTION WITH THE SMOKE CONTAINMENT DOORCOMPLYS WITH SMOKE AND DRAFT DOOR ASSEMBLY REQUIREMENTS IN CBC SECTION 716.2..2.1.1WHEN TESTED IN ACCORDANCE WITH UL 1784 WITHOUT AN ARTIFICIAL BOTTOM.LABELS32.FIRE DOOR ASSEMBLIES SHALL BE LABELED BY AN APPROVED AGENCY. THE LABELS SHALL COMPLYWITH NFPA 80 AND SHALL BE PERMANENTLY AFFIXED TO THE DOOR OR FRAME.33.FIRE DOORS SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER, THE NAME ORTRADEMARK OF THE THIRD-PARTY INSPECTION AGENCY, THE FIRE PROTECTION RATING AND WHEREREQUIRED FOR FIRE DOORS IN EXIT ENCLOSURES AND EXIT PASSAGEWAYS THE MAXIMUMTRANSMITTED TEMPERATURE END POINT. LABELS SHALL BE APPROVED AND PERMANENTLY AFFIXEDAND FACTORY APPLIED. SMOKE AND DRAFT CONTROL DOORS COMPLYING WITH UL 1784 SHALL SHOWTHE LETTER “S” ON THE FIRE RATED LABEL.34.OVERSIZED FIRE DOORS SHALL BEAR AN OVERSIZED FIRE DOOR LABEL BY AN APPROVED AGENCY ORSHALL BE PROVIDED WITH A CERTIFICATE OF INSPECTION BY AN APPROVED TESTING AGENCY.35.FIRE DOOR FRAMES SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER AND THETHIRD-PARTY INSPECTION AGENCY.36.GLAZING - FIRE-PROTECTION- RATED GLAZING SHALL BEAR A LABEL OR OTHER IDENTIFICATIONSHOWING THE NAME OF THE MANUFACTURER, THE TEST STANDARD AND THE FOLLOWING FOUR PARTIDENTIFICATION ISSUED BY AN APPROVED AGENCY AND PERMANENTLY AFFIXED TO THE GLAZING.THE LABEL SHALL BEAR THE FOLLOWING FOUR PART IDENTIFICATION:“D - H OR NH - T OR NT - XXX”D INDICATES THE GLAZING SHALL BE USED IN FIRE DOORS PER NFPA 252H OR NH INDICATES THE GLAZING MEETS OR DOES NOT MEET THE HOSE STREAM TESTT OR NT INDICATES THE GLAZING MEETS OR DOES NOT MEET THE TEMPERATURE REQUIREMENTSXXX INDICATES THE FIRE-PROTECTION-RATING PERIOD IN MINUTES.37.EXTERIOR DOORS SHALL BE INSTALLED BEARING MANUFACTURER'S CERTIFICATE OF COMPLIANCEWITH SPECIFIED THERMAL AND ACOUSTICAL REQUIREMENTS.WEATHERIZATION38.DOORS SHALL HAVE ALL SIX SIDES FACTORY PRIMED OR SEALED AFTER HARDWARE PREPARATION.RESEAL ALL SURFACES IMMEDIATELY AFTER INSTALLATION.39.EXTERIOR DOORS SHALL BE INSULATED AND FULLY WEATHER STRIPPED.40.REFER TO REFERENCED DETAILS OF EXTERIOR DOORS FOR INTEGRATION WITH EXTERIOR WALL ANDTHRESHOLD FLASHING SYSTEMS.41.INSULATE SHIM CAVITY AROUND EXTERIOR DOORS WITH LOW EXPANSION FOAM.42.FOR DOOR/ FRAME ASSEMBLIES IN C.M.U. VERIFY MASONRY OPENING DIMENSIONS.43.PROVIDE SEPARATION BY A TIGHT FITTING DOOR BETWEEN FOOD PREPARATION AREA(S) (INCLUDINGFOOD STORAGE ROOMS) AND TOILET ROOM(S). SECTION 302.6ALALUMINUMANANODIZEDAUTOAUTOMATIC CLOSINGECAELECTRONIC CONTROL ACCESSFFACTORYFGLFIBERGLASSFFFACTORY FINISHFXFIXEDFRFRENCH DOORGLGLASSHCHOLLOW COREHMHOLLOW METALMAMASONITEMCMINERAL COREMTLMETALN/RNON-RATEDOCGOVERHEAD COILING GRILLEOCDOVERHEAD COILING DOORPPAINTPASSPASSAGEPBPUSH BUTTONPFSFPRE-FINISHED STEEL FRAMEPHPANIC HARDWAREPRPAIRPRIVPRIVACY LOCKSSTAINSCSOLID CORESELFSELF CLOSINGSGSEMI-GLOSS PAINTSTRFSTORE FRONTTGTEMPERED GLASSTSTUBE STEELWDWOODLIVING UNIT ENTRY DOORS AND PATIO DOORS SHALL BE SOUND-RATED, PROVIDING A MINIMUMSTC RATING WHEN IN THE CLOSED POSITION IN ACCORDANCE WITH NOTE 10 ABOVE AND THEACOUSTICAL REPORT.4AD-02.0DOOR NOTESDOOR ABBREVIATIONSDOOR STC RATINGSGLAZING PERFORMANCEGLAZING LOCATIONEXTERIOR DOORSBLDG A STOREFRONTU VALUESHGC.45.23.46.22BLDG B STOREFRONT.46.22VT0.10.1U1bA3'-0"7'-0"1 3/4"SCSGWOODSG20UNIT ENTRY DOORU5bF5'-0"6'-8"1 3/8"HCSGWOODSG-CLOSET, PASSAGE HARDWAREAAAAAAA06-21-23
|