My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 3:06:42 PM
Creation date
11/15/2024 9:08:22 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
30
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HEIGHTWIDTHSYMFRAMEFINISHTYPEGLAZINGLOCATIONWINDOW TYPES - DWELLINGS, CORRIDORS & STAIRS WINDOW NOTESSAFETY GLAZINGREMARKSDWELLINGS <br />WINDOW SCHEDULEABBREVIATIONSF:FIXEDS: SLIDERC:CASEMENTT: TEMPEREDBASIS OF DESIGNMATERIAL :FINISH COLOR:MANUFACTURER:EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUSLOCATIONS SHALL BE IDENTIFIED BY A MANUFACTURER'SDESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THEMANUFACTURER OR INSTALLER AND THE SAFETY GLAZINGSTANDARD.SAFETY GLAZING SHALL BE PROVIDED IN HAZARDOUS LOCATIONS.THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUSLOCATIONS FOR THE PURPOSES OF GLAZING:1.GLAZING IN SWINGING DOORS EXCEPT JALOUSIES.2.GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOORASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSETDOOR ASSEMEBLIES.3.GLAZING IN STORM DOORS.4.GLAZING IN UNFRAMED SWINGING DOORS.5.GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS,WHIRLPOOLS,SAUNAS, STEAM ROOMS, BATHTUBS ANDSHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALLENCLOSING THESE COMPARTMENTS WHERE THEBOTTOMEXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHESABOVE A STANDING SURFACE.6.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANELSADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGEOF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHERVERTICAL EDGE OF THE DOOR IN A CLOSED POSITION ANDWHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING ISLESS THAN 60 INCHES ABOVE THE WALKING SURFACE.7.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL,OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND6, WHICH MEETS ALL OF THE FOLLOWING CONDITIONS:7.1.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN9 SQUARE FEET.7.2.EXPOSED BOTTOM EDGE LESS THAN 18 INCHES ABOVETHE FLOOR.7.3.EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVETHE FLOOR.7.4.ONE OR MORE WALKING SURFACE(S) WITHIN 36 INCHESHORIZONTALLY OF THE PLANE OF THE GLAZING.8.GLAZING IN GUARDS AND RAILINGS, INCLUDING STRUCTURALBALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS,REGARDLESS OF AREA OR HEIGHT ABOVE A WALKINGSURFACE.9.GLAZING IN WALLS AND FENCES ENCLOSING INDOOR ANDOUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHEN ALLOF THE FOLLOWING CONDITIONS ARE PRESENT:9.1.THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60INCHES ABOVE A WALKING SURFACE ON THE POOL ORSPA SIDE OF THE GLAZING; AND9.2.THE GLAZING IS WITHIN 60 INCHES HORIZONTALLY THEWATER'S EDGE OF A SWIMMING POOL OR SPA.10.GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPSWITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACE;WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN60 INCHES ABOVE THE PLANE OF ADJACENT WALKINGSURFACE.11.GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHESHORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY INANY DIRECTION WHEN THE EXPOSED SURFACE OF THEGLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THETREAD.EXCEPTION: SAFETY GLAZING FOR ITEMS 10 OR 11 IS NOTREQUIRED FOR THE FOLLOWING INSTALLATIONS WHERE:1) THE SIDE OF A STAIRWAY, LANDING OR RAMP WHICH HASA GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN-FILL PANELS, COMPLYING WITH THE PROVISIONS OF SECTIONS 1013 AND 1607.7; AND2) THE PLANE OF GLASS IS GREATER THAN 18 INCHES FROMTHE RAILING.STC RATED GLAZINGALL OPERABLE AND FIXED WINDOWS AS WELL AS FRENCHDOORS SHALL BE DUAL GLAZED AND HAVE AN STC INACCORDANCE WITH THE ACOUSTICAL REPORT, MIN. STC 28. ALLWINDOW AND DOOR ASSEMBLIES SHALL BE WELL FITTED ANDWELL WEATHERSTRIPPED.1.RESCUE WINDOWS SHALL COMPLY WITH CBC SECTION 1029.2.TEMPERED GLASS SHALL BE PROVIDED WHERE SPECIFIED IN THISSCHEDULE AND ON THE BUILDING, UNIT OR OTHER ENLARGED FLOOR PLANS.3.EXTERIOR GLASS SHALL BE CLEAR DUAL PANE LOW-E WITH MAXIMUM 0.37U-VALUE & MAXIMUM 0.22 SHGC VALUE AS REQUIRED BY THE TITLE 24REPORT.4. INTERIOR GLASS SHALL BE SINGLE PANE, CLEAR.5.TINTED GLASS TO BE NON-REFLECTIVE (NO-MIRROR-LIKE TINTS OR FILMS).6.GLAZING SHALL COMPLY WITH REQUIREMENTS OF CHAPTER 24 OF CBCA6'-0"6'-0"W1VINYLDARKBRONZELOW-EDUAL PANE6'0"x4'3" SLIDING OVER 6'0"x1'9" FIXEDB6'-0"6'-0"W2VINYLDARKBRONZELOW-EDUAL PANE6'0"x4'3" FIXED OVER 6'0"x1'9" FIXEDC6'-0"6'-0"W3VINYLDARKBRONZELOW-EDUAL PANEARCHED TOP CASEMENT OVER 6'0"x1'9" FIXEDD6'-0"6'-0"W4VINYLDARKBRONZELOW-EDUAL PANEARCHED TOP FIXED OVER 6'0"x1'9" FIXEDE6'-0"5'-0"W5VINYLDARKBRONZELOW-EDUAL PANEF4'-0"6'-0"W6VINYLDARKBRONZELOW-EDUAL PANE4'0"x4'3" CASEMENT OVER 4'0"x19" FIXEDG4'-0"6'-0"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENTH3'-0"6'-0"W6VINYLDARKBRONZELOW-EDUAL PANE3'0"x4'3" CASEMENT OVER 4'0"x1'9" FIXED4'-0"6'-0"W7VINYLDARKBRONZELOW-EDUAL PANE4'0"x4'3" FIXED OVER 4'0"x1'9" FIXEDJK3'-0"6'-0"W7VINYLDARKBRONZELOW-EDUAL PANE3'0"x4'3" FIXED OVER 3'0"x1'9" FIXEDL3'-0"6'-0"W9VINYLDARKBRONZELOW-EDUAL PANEFIXEDM3'-0"5'-0"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENTW16'-0"6'-0"1'-9"4'-3"SLIDINGFIXED BELOWFINISH FLOOR8'-0" HEADER HEIGHTW26'-0"6'-0"1'-9"4'-3"FIXEDW3ARCHED TOP CASEMENTFIXED BELOWW46'-0"6'-0" <br />1'-9"2'-9"ARCHED TOP FIXED6'-0"VARIESW5SLIDINGW6VARIES6'-0"1'-9"4'-3"CASEMENTFIXED BELOWFINISH FLOOR8'-0" HEADER HEIGHTW7VARIES6'-0"1'-9"4'-3"FIXEDW8VARIESVARIESCASEMENTW9 VARIESVARIESFIXED <br />3'-0"6'-0"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENTN2'-6"5'-0"W9VINYLDARKBRONZELOW-EDUAL PANEFIXEDP1'-6"6'-0"6'-0"1'-9"2'-9"1'-6"W106'-0"6'-0" <br />1'-9"4'-3"CASEMENT PAIRQ6'-0"6'-0"W10VINYLDARKBRONZELOW-EDUAL PANEPAIR 3'0"x4'3" CASEMENT OVER 6'0"x1'9" FIXEDR4'-0"5'-0"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENTSTAIRS AND CORRIDORS <br />4'-0"6'-0"W9VINYLDARKBRONZELOW-EDUAL PANEFIXEDBA3'-0"6'-0"W7VINYLDARKBRONZELOW-EDUAL PANEBB3'0"x5'0" FIXED OVER 3'0"x1'0" FIXED2'-6"4'-3"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENTBC4'-0"6'-0"W7VINYLDARKBRONZELOW-EDUAL PANEBD4'0"x5'0" FIXED OVER 4'0"x1'0" FIXED4'-0"2'-0"W9VINYLDARKBRONZELOW-EDUAL PANEBEFIXEDFIRERATINGBF6'-0"6'-0"W4VINYLDARKBRONZELOW-EDUAL PANEARCHED TOP FIXED OVER 6'0"x1'0" FIXEDBG6'-0"6'-0"W2VINYLDARKBRONZELOW-EDUAL PANEFIXEDW116'-0"4'-3"CASEMENT PAIRS6'-0"4'-3"W11VINYLDARKBRONZELOW-EDUAL PANEPAIR 3'0"x4'3" CASEMENT. 1ST FLOOR PROVIDE 12" LIMITERT6'-0"4'-3"W5VINYLDARKBRONZELOW-EDUAL PANEU3'-0"4'-3"W8VINYLDARKBRONZELOW-EDUAL PANECASEMENT42" MINIMUMSILL HEIGHT42" MINIMUMSILL HEIGHT <br />42" MINIMUM <br />SILL HEIGHT <br />42" MINIMUMSILL HEIGHT42" MINIMUMSILL HEIGHT <br />42" MINIMUM <br />SILL HEIGHTW12TRANSOM <br />FINISH FLOOR8'-0" HEADER HEIGHT6'-0"1'-4"BH6'-0"1'-4"W12VINYLDARKBRONZELOW-EDUAL PANETRANSOMVINYL WINDOWSCHEDULEA7-30CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA06-21-23ADDENDUM AAAAAAA06-21-23
The URL can be used to link to this page
Your browser does not support the video tag.