Laserfiche WebLink
Door open and closebuttons, where provided,identified by required tactilesymbols and braille andlocated above emergencybuttonsEmergency stop (whereprovided on existing panels- no longer permitted byASME A17.1)Emergency buttons (alarmand, where provided,emergency stop) groupedat bttom 35" min AFFmeasured to buttoncenterline and identified byrequired tactile symbolsand brailleMain Entry Floor (reuiredtactile symbol with braille)Braille (Grade 2) below ornext to raised charactersor symbolsFloor designation buttonsprovide visual indication ofregistered call thatextinguishes upon cararrivalButtons raised from or flushwith faceplate/trim ring(ferrule)Raised characters to immediate left of button, raised1/32" min, sans serif (sufficient color contrast fromthe background is recommended)3/4" min(smallestdimension)3/16" min5/8" - 2"In-car switches not used for passenger use (e.g. fireman'soperations) are not required to comply1/4" BEVELED EDGEKEY SWITCH1/4" ENGRAVEDBLACK LETTERSNOTES:1. VERIFY TEXT WITHELEVATORMANUFACTURER2. THIS SIGN AT EXIT FLOOR ONLY3/4" MINIMUM CALLBUTTONS RAISED 1/8"MIN. ABOVE FACE OFPLATEFIRE RECALL SWITCH ON - RECALLS ELEVATORSTO THIS FLOOROFF - NORMAL ELEVATOR OPERATIONSTO USE ELEVATORTURN FIRE SWITCHIN CAR TO ONPRESS FLOOR BUTTONPRESS DOOR CLOSE BUTTONTO CLOSE DOORPRESS DOOR OPEN BUTTONTO OPEN DOORTURN FIRE SWITCH OFFTO RELEASE ELEVATOR3-6" TO FIN FLR BLACK (ENGRAVED)1/4" BEVEL EDGERED (ENGRAVED)3/4" MINIMUM CALLBUTTONS RAISED 1/8"MIN. ABOVE FACE OFPLATE1/2" HIGH LOWER CASEMEDIUM HELVETICALETTERSIN CASE OF FIREUSE STAIRWAYFOR EXIT -DO NOT USEELEVATOR3'-6" TO FIN FLR <br />ELEVATOR DOORGROUTSILL ANGLE & ATTACHMENTBY ELEV. MANUF.WOOD FRAMINGGYP. BRD.- SEE PLAN FORREQ. FOR WALL ASSEMBLYELEV. DOOR THRESHOLDBY ELEV. MANUF.ELEVATOR SHAFTFLOORING PER PLAN, FINISHSCHEDULE2"x 58" STL. STRINGERSMOUNTING BRACKETS &FASTENERS PER LADDER MFR.SECTIONELEVATIONALIGNREAR WALL ELEVATIONFRONT WALL ELEVATIONEMERGENCY PHONEILLUMINATED CONTROLBUTTONS31" MIN. TO 33" MAX. <br />35" MIN. <br />48" MAX. FRONT APPROACH <br />3" MIN.INTERNATIONAL SYMBOL FOR EMERGENCY MEDICAL SERVICES (STAR OF LIFE)SHALL BE PERMANENTLY ATTACHED TO EACH SIDE OF THE GURNEY/ STRETCHERELEVATOR HOISTWAY DOOR FRAME ON THE PORTION OF THE FRAME AT RIGHT ANGLES TOTHE LANDING OR HALLWAY AREA.6'-6" MIN. TO 7'-0" MAX. <br />ABOVE FIN. FLOORSUPPORT RAILT.O. PITBOT. O. PITWALL ASSEMBLY PER PLAN1" DIA. RUNGS WELDED TOSTRINGERPHOTOELECTRIC TUBEBYPASS SWITCH6'-0" MIN. TO 6'-6" MAX.AT LEAST ONE MEDICALEMERGENCY SERVICE ELEVATORSHALL BE PROVIDED TOACCOMMODATE A 24" x 84"MEDICAL GURNEY ORSTRETCHER W/ NO LESS THAN 5"RADIUS CORNERS. SIZE OFELEVATOR CAR VARIES BYMANUF.1.ELEVATORS SHALL COMPLY WITH ALL FEFERAL, STATE AND LOCAL CODE REQUIREMENTS,INCLUDING BUT NOT LIMITED TO CBC 1124A FOR ACCESSIBILITY AND CBC CHAPTER 30,ELEVATORS.2.ELEVATOR SHALL BE SELF-LEVELING TO WITHIN 1/2" OF THE FLOOR LANDINGS UNDERNORMAL LOADING AND UNLOADING CONDITIONS.THE SELF-LEVELING SHALL, WITHIN ITSZONE, BE ENTIRELY AUTOMATIC AND INDEPENDANT OF THE OPERATING DEVICE AND SHALLCORRECT THE OVER-TRAVEL OR UNDER-TRAVEL. THE CAR SHALL ALSO BE MAINTAINEDAPPROXIMATELY LEVEL WITH THE LANDING IRRESPECTIVE OF THE LOAD. THE CLEARANCEBETWEEN THE CAR PLATFORM SILL AND THE EDGE OF THE HOISTWAY LANDING SHALL BENO GREATER THAN 1-1/4".3.MINIMUM ONE OF THE ELEVATORS PROVIDED SHALL HAVE A CAR DIMENSIONS THAT SHALLACCOMMODATE A 24" X 84" AMBULANCE GURNEY OR STRETCHER WITH NOT LESS THAN 5"RADIUS CORNERS, IN THE HORIZONTAL, OPEN POSITION.4.SUPPORT RAIL SHALL BE PROVIDED (1 MINIMUM) ON ONE WALL OF THE CAR (REARPREFERRED). TOP OF SUPPORT RAIL SHALL BE 31" MIN., 33" MAX. HEIGHT FROM THE FLOORAND SHALL BE MINIMUM 1-1/2" CLEARANCE FROM THE WALL. HANDRAIL SHALL BE SMOOTH,NO SHARP EDGES.5.REFER TO INTERIOR DESIGN DRAWINGS FOR CAR INTERIOR FINISHES6.THE MINIMUM ILLUMINATION AT THE CAR CONTROLS, THRESHOLD AND THE LANDING WHENTHE CAR AND LANDING DOORS ARE OPEN SHALL NOT BE LESS THAN 5 FOOT CANDLES.7.OBJECTS ADJACENT TO AND BELOW HALL CALL BUTTONS SHALL NOT PROJECT MORE THAN4".8.AUDIBLE SIGNAL SOUNDS SHALL BE ONCE FOR UP DIRECTION AND TWICE FOR DOWNDIRECTION (OR EQUIVALENT)9.CONTROLS AND EMERGENCY EQUIPMENT IDENTIFIED BY RAISED LETTERS & SYMBOLSSHALL INCLUDE, BUT NOT BE LIMITED TO, DOOR OPEN, DOOR CLOSE, ALARM BELL,EMERGENCY STOP, AND TELEPHONE.10.COMPARTMENT DOORS FOR EMERGENCY COMMUNICATION DEVICES SHALL BE LEVERTYPE AND SHALL NOT REQUIRE GRASPING, PINCHING OR TWISTING OF THE WRIST TOOPERATE.11.ALL CHARACTER AND SYMBOL BUTTONS SHALL BE DESIGNATED BY A 5/8" MINIMUM RAISEDCHARACTERS AND STANDARD RAISED SYMBOLS AS DESCRIBED IN 1124.3.3.2. GRADE 2BRAILLE SYMBOLS SHALL BE LOCATED IMMEDIATELY BELOW THE RAISED CHARACTERS.12.PROVIDE SMOKE-DETECTION ELEVATOR RECALL AT ELEVATOR ENTRANCE AREAS ANDMACHINE ROOMS.13.ELEVATOR HYDRAULIC LINE, WHEN USED, SHALL BE VIBRATION ISOLATED.14.CONTRACTOR SHALL VERIFY SOIL/WATER TABLE CONDITIONS PER GEOTECHNICAL REPORTAND MAKE NECESSARY ACCOMMODATIONS FOR ELEVATOR INSTALLATION15.CONTRACTOR SHALL VERIFY HOISTWAY AND ELEVATOR EQUIPMENT ROOM SIZES ANDREQUIREMENTS WITH ELEVATOR MANUFACTURER PRIOR TO CONSTRUCTION.NOTE: THIS DRAWING INDICATESACCESSIBILITY REQUIREMENTSONLY-SEE BUILDING PLANS FORADDITIONAL INFORMATION2" HIGH FLOOR NUMBER SHALLBE WHITE ON BLACKBACKGROUND. MAIN ENTRYLEVEL SHALL HAVE RAISEDFIVE-POINTED STAR W/2"OUTSIDE DIAMETER PER C.B.C1124.A.8.CONTRACTED GRADE 2 BRAILLESHALL BE PLACED BELOWCHARACTERS AND THE STARON BOTH JAMBSHALL LANTERN W/AUDIBLE SIGNALELEVATORCALL BUTTONS,SEE DETAILELEVATOR DOOR3'-6" TO FIN. FLR. <br />5'-0" <br />6'-6" MIN. 7'-0" MAX.CLCLCLSTAR OF LIFE AT EACH SIDEOF DOOR FRAME, GURNEY/STRETCHER ELEVATORONLY, SEE DETAIL72" MIN. TO FIN. FLR.CLWALL ASSEMBLY PER PLANDOOR HEAD5/8" TYPE X GYP. BD.HOLLOW METAL DOOR FRAMESMOKE DOOR IN OPEN POSITIONELEVATOR DOOR FRAME, PERMANUFACTURERSMOKE DOOR IN CLOSEDPOSITIONADJUST FRAMING TO FLUSHGYP. BD. WALL FINISH AND SMOKEDOOR IN OPENED POSITIONLINE OF SOFFIT ABOVEVERIFY WITH ELEVATOR MANUFACTURERSEEVERIFY W/ ELEVATOR MANUFACTURERCAB DOOR CLEAR WIDTH + 6"ELEVATOR CALL BUTTONSMOKE DOOR, VERIFY WIDTH IN FIELDHOLLOW METAL DOOR FRAME,FACTORY PRIMEDWALL ASSEMBLY PER PLAN90°SMOKE DOOR IN CLOSEDPOSITIONELEVATOR SHAFTMAGNETIC HOLD OPEN, SHIM AS REQUIREDTO INSTALL DOOR PARALLEL TO BACK WALLELEVATOR DOORSEALANTELEV. DOOR THRESHOLDBY ELEV. MANUF.FLOORING PER PLAN, FINISHSCHEDULEELEVATOR SHAFTSILL ANGLE & ATTACHMENTBY ELEV. MANUF.CONC. PODIUM DECKEDGE OF THRESHOLD FLUSH W/WALLEDGE OF THRESHOLD FLUSH W/WALLELEVATOR DOORGROUTELEV. DOOR THRESHOLDBY ELEV. MANUF.FLOORING PER PLAN & FINISHSCHEDULE. SLOPE FINISHSURFACE AND SUBSTRATEAWAY FROM DOOR @ 1/4" PERFOOT MAXEDGE OF THRESHOLD FLUSH W/WALLPROVIDE SEALANT AND BACKERROD FULL PERIMETER BOTTOMOF HOUSINGAUXILIARY RAILPROVIDE BACKING FOR CURTAINHOUSING MOUNTING PLATESMOKE CURTAIN ASSEMBLY4'-0" MIN. <br />12" TYP.24"10-TYP. CALL BUTTONCALL BUTTON @ EXIT FLOOR7-HOISTWAY DOOR15-1/2"CLR.FLOOR/CEILING ASSEMBLYPER PLANWALL ASSEMBLY PER PLAN1-ELEVATOR SHAFTHOISTWAY DOOR CLEAR WIDTHFURRING AS REQUIREDSIDE / OFF-CENTERED OPENINGCENTERED OPENINGPROVIDE GYP. BD.ENTIRE HEIGHT OFWALLCMU OR PIPCONCRETEHOISTWAY2X METALFRAMING2 LAYERS 58" TYPE'X' GYPSUMWALLBOARDMETAL DOOR& JAMBLOBBYR.O. PER ELEV. MFR.3'-6" CLR.HOISTWAY2 LAYERS 58" TYPE'X' GYPSUMWALLBOARDMETAL DOOR& JAMBCMU OR PIPCONCRETE2X METALFRAMINGSEALANT &BACKER ROD58" GYP. BD. ENTIRELENGTH OF WALLCLIPPED TO WALLPERSONS ABLE TO USE THE EXITSTAIRWAY DO SO AS SOON ASPOSSIBLE, UNLESS THEYARE ASSISTING OTHERS.AFTER ACTIVATINGTHE TWO-WAY EMERGENCYCOMMUNICATION SYSTEM, WAITHERE FOR ASSISTANCELOCATION[ADDRESS]FLOOR[FLOOR][Grade II Braille]DIRECTIONS (EXAMPLE SIGN)DIRECTIONS FOR THE USE OF THETWO-WAY COMMUNICATION SYSTEM,INSTRUCTIONS FOR SUMMONINGASSISTANCE VIA THE TWO-WAYCOMMUNICATION SYSTEM ANDWRITTEN IDENTIFICATION OF THELOCATION SHAL BE POSTED ADJACENTTO THE TWO-WAY COMMUNICATIONSYSTEM. SIGNAGE SHALL COMPLYWITH CHAPTER 11A, SECTION 1143A ORSECTION 11B-703.5 REQUIREMENTSFOR VISUAL CHARACTERS.60" MAX AFF48" MIN AFF PUSH FOR HELPRESCUE ASSISTANCECALL RECEIVEDWHEN LIGHTFLASHINGPUSH FOR HELPEXAMPLE HANDSFREE CALL BOXINDICATOR LIGHTPUSH TO CALL BUTTONSPEAKERREQUIREMENTSTWO-WAY COMMUNICATION SYSTEMSSHALL PROVIDE COMMUNICATIONBETWEEN EACH REQUIRED LOCATIONAND A CENTRAL CONTROL POINTLOCATION APPROVED BY THE FIREDEPARTMENT. WHERE THE CENTRALCONTROL POINT IS NOT AT ACONSTANTLY ATTENDED LOCATION, ATWO-WAY COMMUNICATION SYSTEMSHALL HAVE A TIMED AUTOMATICTELEPHONE DIAL-OUT CAPABILITY TOA MONITORING LOCATION. THETWO-WAY COMMUNICATION SYSTEMSHALL INCLUDE BOTH AUDIBLE ANDVISIBLE SIGNALS.40" MIN AFF48" MAX AFF <br />ELEVATOR DETAILSAD-04ELEVATOR SMOKE DOORELEVATOR SILL @ CONCRETEELEVATOR SILL @ EXTERIORELEVATOR SILL @ INTERIORELEVATOR GURNEY REQ.CALL BUTTON DETAILCONTROL PANELELEVATOR SMOKE CURTAINELEVATOR DOOR HEADERELEVATOR LOBBY ACCESSSTAR OF LIFEELEVATOR PIT LADDERELEVATOR DOOR JAMBELEVATOR CAR ELEVATIONSELEVATOR NOTESCCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM A421876511916151420191824232213---TWO-WAY COMMUNICATIONAA06-21-23