SEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETEINSTALLATION REQUIREMENTSF RATING: 3 HR.PVC PIPE NOMINAL 6" DIAM OR LESSPVC FOAM COR PIPE NOMINAL 6" DIAM OR LESSCPVC NOMINAL 6" DIAMABS NOMINAL 6" DIAM OR LESSABS FOAM CORE NOMINAL 6" DIAM OR LESSTOGGLE BOLTSPEC SEALFIRESTOP COLLARABS PIPEGYPSUM FLOOR / CEILINGASSEMBLYSEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETEINSTALLATION REQUIREMENTSF RATING: 1 & 2 HR.T RATING: 1/2, 3/4, 1 & 1 1/2 HR.STEEL PIPE NOMINAL 4" DIAM OR LESSIRON PIPE NOMINAL 4" DIAM OR LESSCONDUIT NOMINAL 4" DIAMCOPPER TUBING NOMINAL 4" DIAM OR LESSCOPPER PIPE NOMINAL 4" DIAM OR LESS"SPEC SEAL" SERIES100, 101, 102, OR 105SEALANTSTEEL OR IRON PIPEGYPSUM BOARDFLOOR / CEILINGASSEMBLYNON-METALLIC PIPE UP TO 3" DIAM.SEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETE INSTALLATIONREQUIREMENTSSEALANT DEPTH:WRAP STRIP - NOMINAL 1/4" THICK INTUMESCENT MATERIAL FACEDON BOTH SIDES WITH PLASTIC FILL SEALANT MIN. 5/8" THICKNESS W/1/4" CROWN IN ANNULAR SPACE OF MIN 1/4" TO 1-1/4" MAXF RATING: 1 & 2 HR. T RATING: 1, 1-3/4 & 2HR.PVC NOMINAL 3"CPVC NOMINAL 3"RIGID NON-METALLIC CONDUIT NOMINAL 3" DIAMABS NOMINAL 3" DIAMFRPP NOMINAL 2" DIAMPP NOMINAL 1" DIAMGYPSUM BOARDASSEMBLYNON-METALLICPIPE OR TUBING"SPEC SEAL" WRAPSTRIP SPEC SEALBLU"SPEC SEAL" SERIES100, 101,102, OR 105SEALANTSEALANT DEPTH:FILL SEALANT FORCED INTO ANNULUS TO MAX EXTENTPOSSIBLE ON BOTH SIDES W/ 1/4" CROWN ANNULARSPACE 1/4"SEALANT DEPTH:FILL SEALANT FORCED INTO ANNULUS TO MAX ANNULARSPACE 1/4"NON-METALLIC PIPE UP TO 1 1/2" DIAMSEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETEINSTALLATION REQUIREMENTSSEALANT DEPTH:FILL SEALANT MIN. 5/8" THICKNESS W/ 1/4" CROWNANNULAR SPACE NOMINAL 3/8"F RATING: 1 & 2 HR. T RATING: 1 & 1-1/2 HR.POLYBUTLENE PIPE NOMINAL 1" DIAMPEX NOMINAL 1" DIAMABS NOMINAL 1 1/2" DIAMPVC NOMINAL 1 1/2" DIAMCPVC NOMINAL 1 1/2" DIAMGYPSUM BOARDASSEMBLYNON-METALLICPIPE OR TUBING"SPEC SEAL" SERIES100, 101, 102, 0R 105SEALANTNON-METALLIC PIPE UP TO 2" DIAM (NOT ABS)SEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETEINSTALLATION REQUIREMENTSSEALANT DEPTH:FILL SEALANT MIN. 5/8" THICKNESS W/ 1/4" CROWN LAPPING 1"BEYOND THE OPENING ANNULAR SPACE NOMINAL 5/16"GYPSUMBOARDASSEMBLYNON-METALLICPIPE CONDUIT,RACEWAY ORTUBING"SPEC SEAL"SERIES 100 101, 102,OR 105 SEALANTELECTRICALCABLESGYPSUM BOARDASSEMBLYF RATING: 1 & 2 HR. T RATING: 0UP TO 4" CABLE BUNDLESEALANT DEPTH:FILL SEALANT MIN. 5/8" THICKNESS 3/8" CROWN BEAD AT CONTACTPOINT ANNULUS RANGING FROM POINT CONTACT TO 1/2" MAXSEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETE INSTALLATIONREQUIREMENTSSEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETEINSTALLATION REQUIREMENTSSEALANT DEPTH:FILL SEALANT MIN. 5/8" THICKNESS 3/8" CROWN BEAD AT CONTACTPOINT ANNULUS RANGING FROM POINT CONTACT TO 1-1/2" MAXGYPSUM BOARDASSEMBLYSTEEL OR IRONPIPE OR CONDUIT"SPEC SEAL" SERIES100 SEALANTF RATING: 1 & 2 HR. T RATING: 0 HRSTEEL PIPE NOMINAL 24" DIAM OR LESSIRON PIPE NOMINAL 24" DIAM OR LESSCONDUIT NOMINAL 4" DIAMCOPPER PIPE NOMINAL 6" DIAM OR LESSCOPPER TUBING NOMINAL 6" DIAM OR LESSF RATING: 1 & 2 HR. T RATING: 1 & 1-1/2 HR.PVC NOMINAL 2" DIAM.RIGID NON-METALLIC CONDUIT NOMINAL 2" DIAM. CPVCNOMINAL 2" DIAM.OPTICAL FIBER RACEWAY FROM PVC NOM. 2" DIAM.OPTICAL FIBER RACEWAY FROM PVDF NOM. 1 1/4" DIAM.ELECTRICAL NON-METALLIC TUBING NOM. 2" DIAM."SPEC SEAL"SERIES 100 101,102, OR 105SEALANTUL SYSTEM NO. WL1049UL SYSTEM NO. WL3076UL SYSTEM NO. WL2093UL SYSTEM NO. WL2100AUL SYSTEM NO. WL2048BUL SYSTEM NO. FC1010UL SYSTEM NO. UL1479CEXHAUST DUCT SEE MECH.PLANS FOR SIZINGVYCOR OR EQUAL LAP W/ VENTDRYER VENT WEATHER HOODW/ BACKDRAFT DAMPERVYCOR OR EQUAL O/ VENTFLANGE, HEAD & SIDES7/8" THK. EXT. PLASTER O/ GALV.MTL. LATHFIRESTOP SEALANT ALL AROUND -"SPEC SEAL" SERIES 100, 101, 102,OR 105 SEALANT OR SPEC SEAL"LCI"14" SEALANT AND BACKER RODAT JOINTS ALL AROUNDDRYER VENT FLANGE-BEYONDADDITIONAL LAYER OF VYCOR7/8" THK. EXT. PLASTER O/ GALV.MTL. LATHFLOOR / CEILING ASSEMBLY1" <br />MAX3 1/2"MAX6" DIAMAX3/4" <br />MINMAX 6" DIA OPENING WITH NOM 2" (OR SMALLER) STEEL, IRON OR COPPER PIPEF RATING - 3 HR BASED ON STI ENGINEERING JUDGEMENT REF L302401JPT RATING - 3 HR BASED ON MORGAN ADVANCED MATERIALS ENGINEERING JUDGEMENT110655TP02TUB DRAIN PENETRATION1.MIN 4 PCF MINERAL WOOL TIGHLY PACKED INTOTHE OPENING TO A MAX 1" DEPTH ANDRECESSED INTO THE OPENING MIN 5" FROMBOTTOM SURFACE OF FLOOR2.MIN 3/4" SPECSEAL SSS OR LCI SEALANT3.MINERAL WOOL TIGHTLY PACKED INTO ANNULUSTO REMAINING DEPTH OF FLOOR4.NOM 2" DIA STEEL, IRON OR COPPER PIPE5.3-LAYERS FIREMASTER FASTWRAP XL MIN 36"DISTANCE ALONG PIPE5" <br />MIN 1233-HR HORIZ ASSYTHROUGH PENETRATION FIRESTOP1/2"MINDATED 4/9/15 ATTACHED345NOTE: CONTINUOUS SPECIALINSPECTION REQUIREDDETAIL REFLECTS STAFFFINDINGS PER AMMCAPPROVED 4/17/151" <br />MAX 6" DIAMAX3/4" <br />MINF RATING - 3 HR BASED ON STI ENGINEERING JUDGEMENT REF L302402JPT RATING - 0 HR110655TP01BLANK OPENING FIRESTOP1.MIN 4 PCF MINERAL WOOL TIGHLY PACKED INTOTHE OPENING TO A MAX 1" DEPTH ANDRECESSED INTO THE OPENING MIN 5" FROMBOTTOM SURFACE OF FLOOR2.MIN 3/4" SPECSEAL SSS OR LCI SEALANT3.MINERAL WOOL TIGHTLY PACKED INTO ANNULUSTO REMAINING DEPTH OF FLOOR5" <br />MIN 1233-HR FLOORMODIFIED THROUGH PENETRATION FIRESTOP FOR BLANK HOLENOTE: CONTINUOUS SPECIALINSPECTION REQUIREDDETAIL REFLECTS STAFFFINDINGS PER AMMCAPPROVED 4/17/1518 SQ FT MAX OR6'-0" DIA MAXMAX 18 SQ FT OR SINGLE 6 FT DIA OPNG WITH 1 OR MORE PENETRANTSF RATING - 3 HR BASED ON UL SYSTEM NO. C-AJ-8093T RATING - 3 HR BASED ON MORGAN ADVANCED MATERIALS ENGINEERING JUDGEMENT1.Nominal 9 inch long by 4 to 6 inch by 1 to 3 inch thickplastic covered intumescent SpecSeal Firestop Pillowsby STI in accordance with UL System No. C-AJ-80932.1 or more metallic or non-metallic penetrants describedin UL System No. C-AJ-80933.3-layers Firemaster FastWrap XL minimum 36 inchesdistance along pipe9" <br />NOM1 <br />3-HR HORIZ ASSY <br />12" CONCTHROUGH PENETRATION FIRESTOPDATED 5/7/15 ATTACHED23NOTE: CONTINUOUS SPECIALINSPECTION REQUIREDDETAIL REFLECTS STAFFFINDINGS PER AMMCAPPROVED 5/7/152 1/2" <br />MAX <br />SEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETE INSTALLATION REQUIREMENTSF RATING: 2 & 3 HR.T RATING: 0, 1, 2 & 3 HR.PVC PIPE NOMINAL 6" DIAM OR LESSCPVC PIPE NOMINAL 6" DIAM OR LESSRIGID NON-METALLIC CONDUIT NOMINAL 6" DIAMABS PIPE NOMINAL 6" DIAM OR LESSFRPP PIPE NOMINAL 6" DIAM OR LESSHDPE PIPE NOMINAL 6" DIA OR LESSSEALANT OR PUTTYPER UL REPORTNON-METALLIC PIPEFILL, VOID ORCAVITY MATERIAL -WRAP STRIP PER ULREPORTFIRESTOP SYSTEM:REFER TO UL REPORT FOR SPECIFIC CONDITION & FIRESTOP OPTIONS. THERE IS A TABLEOF MULTIPLE SCENARIOS AND OPTIONS TO CHOOSE FROM.UL SYSTEM NO. C-AJ-2297CONCRETE FLR/WALL NON-METALLICCONCRETE FLR/WALL METALLICSEE UL FIRE RESISTANCE DIRECTORY FOR COMPLETE INSTALLATION REQUIREMENTSF RATING: 3 HR.T RATING: 0 HR.STEEL PIPE NOMINAL 4" DIAM OR LESSCONDUIT NOMINAL 4" DIAM OR LESSCOPPER TUBING NOMINAL 3" DIAMIRON PIPE NOMINAL 6" DIAM OR LESSSEALANT PER ULREPORTMETALLIC PIPEPACKING MATERIALPER UL REPORTFIRESTOP SYSTEM:PACKING MATERIAL - MIN 3-3/4 IN. THICKNESS OF MIN. 4.5 PCF MINERAL WOOL BATTINSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM SO THAT THE WIDTHOF THE WOOL IS COMPRESSED AT LEAST 50 PERCENT. PACKING MATERIAL TO BERECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL ASREQUIRED TO ACCOMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.FILL, VOID OR CAVITY MATERIAL - SEALANT MIN 14 IN. THICKNESS OF SEALANT APPLIEDWITHIN THE ANNULUS, FLUSH WITH THE TOP SURFACE OF FLOOR OR WITH BOTHSURFACES OF WALL.3M COMPANY: FB-1000 NS (FLOORS OR WALLS) OR FB-1003SLUL SYSTEM NO. C-AJ-1292WOOD FRAMED FLR/CLG NON-METALLICWOOD FRAMED FLR/CLG METALLICWALL NON-METALLICWALL ELECTRICAL CABLE BUNDLEWALL METALLIC PIPE OR CONDUITVENT PENETRATION AT EXTERIOR WALL1-HR CONDITION2-HR CONDITION1 LAYER OF 5/8" TYPE "X"GYPSUM BOARD2 LAYERS OF 5/8" TYPE "X"GYPSUM BOARDFOR INFORMATION NOTSHOWN, SEE 1 HR CONDITIONBELOWCCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM AFIRE PENETRATIONDETAILSAD-20.1432678121611101906-21-23