My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 3:06:42 PM
Creation date
11/15/2024 9:08:22 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
30
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIT LIVING SPACEEXTERIOR CORRIDORUNIT LIVING SPACEUNIT LIVING SPACESET SILL PLATE ON (3) CONTINUOUSBEADS OF SEALANTINTERIOR CORRIDORSET SILL PLATE ON (3) CONTINUOUSBEADS OF SEALANTTYPICAL RATED INTERIORFLOOR / CEILING3AD-21UNIT LIVING SPACE2AD-22INTERIOR CORRIDORINTERIOR CORRIDORUNIT LIVING SPACERATED CORRIDOR WALL,STAGGEREDEXTERIOR CORRIDORorBALCONYTOPPING SLABWHERE OCCURSRATED CORRIDOR WALL,STAGGERED2AD-22SOUND INSULATION; SEE ENERGYREPORT FOR REQUIRED BUILDINGINSULATION.TYPICAL RATED EXTERIORFLOOR / CEILINGRATED FLOOR / CEILING ATDROPPED SOFFITEXTERIOR CORRIDORLIGHT IN NON-RATEDCEILING / SOFFITSOUND INSULATION; SEE ENERGYREPORT FOR REQUIRED BUILDINGINSULATION.SET SILL PLATES ON (3) CONT. BEADSOF SEALANTTYPICAL RATED FLOOR /CEILINGRATED ROOF / CEILINGASSEMBLYRATED WALLASSEMBLYFIREBLOCKING INCONCEALED WALL SPACES,CBC 717.2.2CONCRETE SLABAIRSPACEPER PLAN9AD-21UNIT3AD-221AD-21UNITUNITUNITUNITSOUND INSULATION;SEE ENERGYREPORT FORREQUIRED BUILDINGINSULATION.UNIT LIVING SPACE5/8" TYPE X GYPSUM WALLBOARDOVER METAL CEILING FRAMING.NOTE:SEE DETAIL 4/ FOR INFORMATIONNOT SHOWNNOTE:SEE DETAIL 4/ FOR INFORMATIONNOT SHOWN14AD-2115AD-2116AD-2115AD-21TYPICAL RATED FLOOR /CEILING1AD-21UNITINTERIORSTAIRRATED ROOF / CEILINGASSEMBLY2 HR RATED WALLASSEMBLY9AD-21UNIT7AD-22SET SILL PLATES ON (3) CONT. BEADSOF SEALANTCONCRETE SLABFIREBLOCKING INCONCEALED WALL SPACES,CBC 717.2.2FIREBLOCKING INCONCEALED WALL SPACES,CBC 717.2.2FRAMINGPERPENDICULARFRAMING PARALLELTYPICAL RATED FLOOR /CEILING1AD-21UNITTYPICAL RATED FLOOR /CEILING1AD-21UNITSTAIR SHAFTFRAMING OPTION - 2FRAMING OPTION - 3LEDGER PER STRUCTURALTOP-FLANGE HANGER FORDRYVALL CONTINUATIONSTAIR SHAFT2 HR RATED WALLASSEMBLYUNIT7AD-221 HR RATED WALLASSEMBLYINTERIORSTAIRRATED ROOF / CEILINGASSEMBLY9AD-21RATED ROOF / CEILINGASSEMBLY10AD-21DRAFTSTOPPING PER CBC 708.4.2TYPICAL RATED INTERIORFLOOR / CEILING1AD-2124AD-21FRAMING PERPENDICULARFRAMING PARALLELFRAMING PARALLELFRAMING PARALLELFRAMING PARALLELFRAMING PARALLEL1-HOUR FIREPARTITION DETAILSAD-22.11-HR RATED INTERIOR CORRIDOR TO UNIT20122-HR RATED FIRE BARRIER STAIR SHAFT TO UNIT1-HR RATED EXTERIOR CORRIDOR TO UNIT1-HR RATED FIRE PARTITION UNIT TO UNIT84CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM A06-21-23
The URL can be used to link to this page
Your browser does not support the video tag.