RATED FIRE PARTITION <br />ONE LAYER OF 5/8" TYPE'X' GYPSUM BOARDRATED WALL, EXTERIOR RATED WALL, STAGGEREDRATED WALL, INTERIORINTERIOR SIDEEXTERIOR SIDEINTERIOR SIDE <br />ASSEMBLY COMPLIES WITH:CBC TABLE 721.1(2) ITEM NUMBER 15-1.3ICC REPORT No. ER-19522X WOOD STUDS16" O.C.EXTERIOR CEMENT PLASTER O/METAL LATH O/ WATER RESISTIVEBARRIEREXTERIOR SHEATHINGWHERE OCCURSWALL INSULATION PERT-24 REQIREMENTSWHERE FIRE RETARDANT TREATED FRAMING ANDSHEATHING IS REQUIRED, ANY METAL STAPLES,STRAPS, NAILS, ETC. THAT COME IN CONTACT WITHFIRE RETARDANT TREATED LUMBER IS TO BECORROSIVE RESISTANT.2X WOOD STUDSEXTERIOR CEMENTPLASTER O/ METALLATH O/ WRBEXTERIOR SHEATHINGWHERE OCCURSONE LAYER OF 5/8" TYPE'X' GYPSUM BOARD ONBOTH SIDES OF WALLASSEMBLY COMPLIES WITH:CBC TABLE 721.1(2) ITEM NUMBER 15-1.3ICC REPORT No. ER-19522X WOOD STUDS16" O.C.EXTERIOR CEMENT PLASTER O/METAL LATH O/ WATER RESISTIVEBARRIEREXTERIOR SHEATHINGWHERE OCCURSWALL INSULATION PERT-24 REQIREMENTSRATED ASSEMBLY <br />PER PLAN FILL WALL CAVITY WITHINSULATIONINTERIOR SIDEEXTERIOR SIDEEXTERIOR SIDEINTERIOR SIDEEXTERIOR SIDEEXTERIOR SIDENOTE: SUBSTITUTE 78" EXTERIORPLASTER IN LIEU OF ONE LAYER OF58" 'TYPE X' GYPSUM BOARDNOTE: SUBSTITUTE 78" EXTERIORPLASTER IN LIEU OF ONE LAYER OF58" 'TYPE X' GYPSUM BOARDNOTE: EXTERIOR CLADDING OVERWATER RESISTIVE BARRIER LOCATEDON EXTERIOR SIDE WHERE OCCURSFIRE-RATED EXTERIORWALL DETAILSAD-241-HR RATED WOOD FRAMED WALL51-HR RATED WOOD FRAMED WALL12-HR RATED WOOD FRAMED WALL22-HR RATED WOOD FRAMED WALL61-HR RATED MTL. FRAMED WALL782-HR RATED MTL. FRAMED WALL431-HR RATED MTL. FRAMED WALL2-HR RATED MTL. FRAMED WALLCCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM ANON-RATED WOOD FRAMED WALL91-HR RATED FURRED WALL10RATED WALL INTERSECTIONS1206-21-23