My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packet_2024-11-19
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Agenda Packet_2024-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 8:48:28 AM
Creation date
11/19/2024 8:40:58 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9" <br />24"12"12" <br />12"12"12" <br />12"12"12"12"12"12" <br />9" <br />9" <br />9"9"12" <br />12" <br />12" <br />(134) <br />(132) <br />(130) <br />(128) <br />(126) <br />(124)(122)(120)(118)(116)(114) <br />(112) <br />- <br />(144) <br />(141) <br />(14 <br />1) <br />(143) <br />(1 4 4 ) <br />(121) <br />(122) <br />(123) <br />(124) <br />(126) <br />(127) <br />(128) <br />(129) <br />(131) <br />(13 <br />2) <br />( <br />1 <br />33 <br />) <br />(134)(139)(139) <br />(138)(120)(125) <br />(130) <br />(135) <br />(140) <br />6" <br />6" <br />6" <br />6"6"6"TTTTT T <br />T TT <br />T <br />T <br />DN <br />A3.02 <br />A3.01 <br />A3.012 <br />A3.02 2 <br />1 <br />1 <br />17 <br />A <br />16151413121110987654321 <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />J <br />K <br />L <br />M <br />N <br />A3.02 <br />3 <br />A3.02 <br />4 <br />14.4 <br />CABRILLO PARK DRIVEXEROX CENTER <br />STATE FUND DRIVE(E) 6 LEVEL PARKING GARAGE <br />(E) 6 LEVEL PARKING GARAGE <br />STAIRCASE ON A <br />SEPARATE PERMIT <br />E X IS T IN G T O R E M A IN <br />ø 8 0 ' - 0 "EX <br />I <br />STING TO REMAIN <br />ø 80' - 0" <br />LANDSCAPE <br />STOR <br />1083JANITOR STOR <br />1077 <br />STOR <br />1078 <br />STOR <br />1075 <br />STOR <br />1076 <br />BIKE <br />1080 <br />TRASH <br />1081 <br />ELECTRICAL <br />ROOM <br />1071 <br />STAIR 2 <br />1070 <br />INVERTER <br />1069 <br />FIRE PUMP <br />1068 <br />MPOE <br />1067 <br />MAIN ELEC <br />1066 <br />TRASH <br />1064 <br />F.C.C <br />1062 <br />STAIR 1 <br />1060 <br />FAN ROOM <br />1073 <br />ELEV MACH <br />1059 <br />MAIL/PARCEL <br />1103 <br />COPY/KEY <br />1105 <br />LEASING <br />1058 <br />RETAIL <br />1001 <br />RETAIL <br />1053 <br />UNIT LW-01 <br />1054 <br />UNIT LW-01 <br />1055 <br />UNIT LW-01 <br />1056 <br />UNIT LW-01 <br />1057 <br />OFFICE <br />1102 <br />RESTRM <br />1101 <br />STAIR 4 <br />1084 <br />CORRIDOR <br />1085 <br />VEST <br />1086 <br />STOR <br />1087 <br />STAIR 3 <br />1079 <br />VISITOR <br />PARKING <br />1063 <br />ELEV LOBBY 4 <br />1082 <br />RESIDENTIAL <br />PARKING <br />1090 <br />RESIDENTIAL <br />PARKING <br />1096 <br />ELEV LOBBY 2 <br />1074 <br />ELEV LOBBY 1 <br />1061 <br />ENTRY VEST <br />1100 <br />STAIR 5 <br />1104 <br />STOR <br />1088 <br />1:12 <br />1:12 <br />PROPERTY LINE <br />PROPERTY LINEPROPERTY LINEPROPERTY LINE <br />PROPERTY LINE <br />(E) HYDRANT <br />TO REMAIN <br />TRANSFORMER <br />TRANSFORMER <br />FIRE TRUCK <br />STAGING AREA <br />SETBACK10' - 0"SETBACK30' - 0"FIRE ACCESS LANE <br />SETBACK <br />20' - 0"SETBACK10' - 0"29' - 3" <br />21' - 0" <br />23' - 1"25' - 0" <br />SETBACK <br />20' - 0" <br />GREASE INTERCEPTOR <br />GREASE INTERCEPTOR <br />(E) HYDRANT <br />(N) HYDRANT <br />5%DN <br />DN <br />DN <br />SETBACK LINE <br />PROPERTY LINE <br />FIRE HYDRANT <br />ZONE "X"DENOTES UNITS REQUIRING WINDOW/ DOOR <br />ACOUSTICAL UPGRADES <br />FIRE ACCESS TO BUILDING <br />VEHICLE GARAGE DRIVE RAMP ACCESS <br />8'-2" MIN CLEAR HEAD HEIGHT <br />ADA TACTILE SURFACE <br />1. THE SITE PLAN WAS PREPARED USING INFORMATION PROVIDED BY THE CIVIL ENGINEER <br />AND THE LANDSCAPE ARCHITECT. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION <br />RELATED TO THE ARCHITECTURAL ELEMENTS OF THE BUILDING ONLY. <br />2. REFER TO CIVIL AND LANDSCAPE FOR INFORMATION PERTAINING TO THE DEVELOPMENT <br />OF THE SITE. THIS INCLUDES HORIZONTAL AND VERTICAL DIMENSION CONTROL, <br />SETBACKS, GRADING & EXCAVATION, LANDSCAPING AT GRADE AND PODIUM, SITE <br />ACCESSIBILITY, AND OTHER SITE DEVELOPMENT INFORMATION. <br />3. SETBACK DIMENSIONS INDICATED ARE FOR REFERENCE ONLY. REFER TO CIVIL PLANS <br />FOR PRECISE HORIZONTAL CONTROL INFORMATION. REFERENCE CIVIL AND LANDSCAPE <br />DOCUMENTS FOR COMPLETE SITE INFORMATION. <br />4. REFER TO THE PROJECT GEOTECHNICAL REPORT FOR ADDITIONAL SITE REQUIREMENTS. <br />5. REFER TO THE DRY UTILITY CONSULTANT DOCUMENTS FOR SITE WORK, INCLUDING <br />LOCATION AND SIZES OF TRANSFORMERS. <br />6. REFERENCE GEN-1.0 FOR PARKING COUNTS. <br />7. REFERENCE GEN-6,7 & 8 FOR ACCESSIBILITY REQUIREMENTS. <br />8. REFERENCE STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL, LIGHTING FOR <br />ADDITIONAL INFORMATION. <br />9. APPROVED BUILDING ADDRESS NUMBERS TO BE PROVIDED AND MAINTAINED AS TO BE <br />VISIBLE FROM THE STREET FRONTING THE PROPERTY. LETTERS TO BE MIN. 4" HIGH AND <br />MIN. STROKE WIDTH OF 0.5" . <br />10. ALL ELEVATORS FOR THE PROJECT SHALL COMPLY WITH CBC CHAPTER 30. ALL <br />PASSENGER ELEVATORS SHALL MEET THE REQUIREMENTS OF MEDICAL EMERGENCY <br />RESPONSE SERVICE ELEVATOR TO ALL LANDINGS PER THE REQUIREMENTS OF CBC <br />SECTION 3002.4.1A THROUGH SECTION 3002.4.7 <br />11. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED PER THE FIRE CODE SECTION <br />906. <br />12. GRAPHIC DISPLAY PANEL TO BE PROVIDED AT ALL VEHICULAR ENTRANCES WHICH <br />DEPICTS LOCATION OF ALL RESIDENTIAL UNITS <br />13. PER CBC SECTION 11B-302: GROUND AND FLOOR SURFACES ALONG ACCESSIBLE <br />ROUTES AND IN ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS, <br />STAIRS AND CURB RAMPS, SHALL BE STABLE, FIRM, SLIP RESISTANT. <br />1. ACCESSIBLE PATH OF TRAVEL AS INDICATED ON PLAN IS A BARRIER FREE ACCESS <br />ROUTE WITHOUT ANY ABRUPT LEVEL CHANGES EXCEEDING 1/2" IF BEVELED AT 1:2 MAX <br />SLOPE, OR VERTICAL LEVEL CHANGES NOT EXCEEDING 1/4" MAX IN HEIGHT ALONG AND <br />ADJACENT TO THE ACCESSIBLE ROUTE OF TRAVEL, AND AT LEAST 48" IN WIDTH. CROSS <br />SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN <br />5%, UNLESS OTHERWISE INDICATED. ACCESSIBLE PATH OF TRAVEL SHALL BE <br />MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM, AND PROTRUDING <br />OBJECTS GREATER THAN 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN <br />80". ACCESSIBLE ROUTE SURFACE MUST BE SLIP-RESISTANT, STABLE, AND FIRM. ON <br />SURFACES WITH SLOPES UP TO 6%, PROVIDE EQUIVALENT OF MEDIUM SALTED FINISH. <br />ON SURFACES WITH SLOPES EQUAL TO OR GREATER THAN 6%, PROVIDE SLIP-RESISTANT <br />FINISH. <br />SITE ACCESSIBILITY NOTES <br />SITE PLAN LEGEND <br />ADA PATH OF TRAVEL <br />1. NO TICKET BOOTH ON SITE FOR RETAIL PARKING. <br />2. RIGHT TURN ONLY FROM GARAGE ENTRACE TO 7TH STREET <br />3. SIGNAGE WILL BE PROVIDED FOR NO LEFT TURN ON 7TH STREET <br />4. ALL RETAIL STALLS ARE IDENTIFIED AS 'RETAIL'. REFER TO FLOOR PLANS. <br />GENERAL NOTES <br />RENEWAL <br />DATE <br />RCHITE <br />CTDESNECIL A <br />A L IF ORNIA <br />FOETATSC <br />JOHNNY C. LU <br />C-30396 <br />6/30/2023 <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.Job No.: <br />Drawn: <br />Checked: <br />BID Date:411 EAST HUNTINGTON DRIVESUITE 308ARCADIA, CALIFORNIA 91006PHN: (626) 446-5300TAG design worksSHEET # <br />SHEET TITLE:200 N. CABRILLO, SANTA ANA, CA 92701ARCHITECT:PROJECT ADDRESS:THE MADISON3/28/2022 DD SET <br />4/22/2022 100% DD <br />1ST BUILDING DEPT SUBMITTAL 05-31-20225/31/2022 1ST PLAN CHECK <br />Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt <br />SITE PLAN <br />A1.00 <br />GENERAL NOTES <br />XKEY NOTES <br />1" = 20'-0"1SITE PLAN <br />Date Issues / Revisions: <br />SYMBOL DESCRIPTION <br />1 STREET CURB - SEE CIVIL PLAN <br />2 NEW CURB CUT FOR DRIVEWAY ENTRY _ SEE CIVIL PLANS <br />3 WATER METER(S) - SEE CIVIL PLANS AND PLUMBING PLANS <br />4 GAS METER - SEE PLUMBING PLANS <br />5 ELECTRICAL SWITCHGEAR -SEE ELECTRICAL DWG'S., PROVIDE <br />4" HIGH CONC. PAD WHEN LOCATED @ EXTERIOR OF BUILDING. <br />6 TRANSFORMER/ELECTRICAL VAULT - SEE ELECTRICAL PLANS <br />7 DETECTOR CHECK / FDC, PROVIDE 1" CONDUIT TO BUILDING <br />FIRE SPRINKLER RISER <br />8 P.I.V., PROVIDE 1" CONDUIT TO BUILDING FIRE SPRINKLER <br />RISER - SEE CIVIL PLANS <br />9 BACKFLOW PREVENTOR(S) - SEE CIVIL PLANS <br />10 SEWER LINE - SEE PLUMBING PLANS <br />11 IRRIGATION METER <br />12 FUTURE STANDPIPE(CLASS I) LOCATION - SEE FIRE SPRINKLER <br />SYSTEM DWG'S. (DEFERRED SUBMITTAL) <br />13 ELEVATOR WITH THE STRETCHER REQUIREMENTS OF <br />BUILDING CODE 3002.4. PROVIDE 90 MINUTE FIRE RATED <br />DOOR. PROVIDE STAR OF LIFE SIGNAGE. <br />14 DRAINAGE DEVICE - SEE CIVIL AND PLUMBING PLANS <br />15 EXISTING FIRE HYDRANT - SEE CIVIL PLANS <br />16 PROPOSED NEW FIRE HYDRANT - SEE CIVIL PLANS <br />17 ELECTRICAL PANEL <br />18 TELEPHONE TERMINAL BACKBOARD <br />19 6'-0" HIGH CMU WALL WITH STUCCO FINISH, MEASURE FROM <br />FINISHED GRADE. REPAIR ANY DAMAGE WHERE OCCURS. <br />20 NEW DRIVEWAY APPROACH PER CITY STANDARD - SEE CIVIL <br />PLANS <br />21 CENTRAL MAIL BOXES <br />CENTRAL MAILBOXES <br />22 CONCRETE WALKWAY <br />CENTRAL MAILBOXES <br />23 6" CONCRETE CURB <br />24 LONG-TERM BIKE RACK IN LOCKABLE BIKE STORAGE ROOM <br />25 SHORT-TERM BIKE RACK <br />26 BOLLARD(S) <br />27 WHEEL STOP <br />28 PARKING STRIPING <br />29 HANDICAP ACCESSIBLE PARKING SPACE(S) <br />30 BUILDING LINE ABOVE <br />31 HANDICAP ACCESSIBLE PARKING SPACE FOR RESIDENTIAL <br />UNIT - 2% SLOPE MAX IN ANY DIRECTION <br />32 VAN ACCESSIBLE PARKING SPACE FOR GUEST PARKING SPACE <br />- 2% SLOPE MAX IN ANY DIRECTION. KEEP MIN. 8'-2" CLR. <br />HEADROOM <br />33 "GUEST PARKING ONLY" SIGN <br />34 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN- INDICATE <br />THE DIRECTION TO ACCESSIBLE BUILDING ENTRANCES <br />35 ELECTRIC CHARGING STATION FOR FUEL-EFFICIENT VEHICLES <br />36 HARDSCAPE/ PAVING <br />37 DECORATIVE SCREEN WALL <br />38 DECORATIVE STAMPED CONCRETE <br />39 THICKEN CONCRETE SLAB <br />40 MONUMENT SIGN (N.A.P., UNDER SEPARATE PERMIT) <br />41 ACCESSIBLE RAMP AND DETECTABLE WARNING WHERE <br />REQUIRED, SEE CIVIL PLANS <br />42 6 FT. HT. METAL FENCE (N.A.P., UNDER SEPARATE PERMIT) <br />43 DECORATIVE BOLLARD(S) WITH LIGHT <br />44 EV CHARGING STATION <br />45 PEDESTRIAN GATE- LEVER TYPE DOOR HANDLE <br />46 ELEVATOR BACKUP POWER SYSTEM <br />(N.A.P., UNDER SEPARATE PERMIT) <br />47 5 FT. HT. FENCE WALL WITH SMOOTH STUCCO FINISH - <br />PROVIDE VISUAL SCREENING FOR GAS METERS <br />48 FIRE LANE - NO PARKING FIRE LANE MARK ON CURB <br />49 HOSE BIBB - SEE PLUMBING PLANS <br />1. SEE CIVIL PLANS FOR GRADING INFORMATION <br />2. SEE LANDSCAPE PLANS FOR LANDSCAPE INFORMATION. <br /> <br /> <br />City Council 29 – 38 11/19/2024
The URL can be used to link to this page
Your browser does not support the video tag.