Agenda Packet_2024-11-19
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Agenda Packet_2024-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 8:48:28 AM
Creation date
11/19/2024 8:40:58 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5' - 11"10' - 6"PER OVERALL PLANS4' - 8"33' - 6"PER OVERALL PLANS36' - 8" <br />BEDROOM-1 <br />CLOSET <br />CLOSETBATH-1KITCHEN <br />LIVING <br />DINING <br />BALCONY <br />BEDROOM-2 <br />CLOSET <br />W/D <br />BATH-2 <br />CLOSET24' - 7" <br />8' - 1"6' - 0"10' - 6" <br />4' - 8" <br />BEDROOM-1 <br />CLOSET <br />BATH-1 <br />LIVING <br />DINING <br />BEDROOM-2 <br />CLOSET <br />W/D <br />BATH-2 <br />KITCHEN <br />BALCONY <br />9' - 0"6' - 2"11' - 5" <br />26' - 7" <br />4' - 9"41' - 8"41' - 8"14' - 5" <br />BALCONY <br />BEDROOM-1 <br />BATH-1 <br />BATH-2 <br />W/D CLOSETCLOSET <br />KITCHEN <br />BEDROOM-2 <br />LIVING <br />DINING <br />W.H.HVAC <br /># <br /># <br />ELECTRICAL PANEL <br />COMMUNICATION CONTROL BOX <br />CARBON MONOXIDE <br />DETECTOR/ALARM <br />DOOR BELL <br />INCANDESCENT LIGHTING <br />CEILING MOUNTED <br />EXHAUST FAN W/ HUMIDITY <br />SENSOR W/MIN. 50 CFM <br />WALL MOUNTED LIGHT <br />THERMOSTAT <br />4" CEILING RECESSED <br />INCANDESCENT LIGHTING <br />INCANDESCENT LIGHTING <br />CEILING RECESSED <br />MOISTURE PROTECTED <br />KITCHEN/BATHROOM TYPE <br />DETAIL # / SHEET #GR GRID LINE <br />WATR HEATER WITH 30" <br />HT. BUILD OUT BOX <br />HVAC FAN UNIT <br />DOOR # SEE SHEET A7.1 WINDOW TYPE, SEE <br />WINDOW SCHEDULE <br />SMOKE DETECTOR/ALARM-SEE <br />NOTE 11 <br />TELEPHONE OUTLETTELEVISION / CABLE OUTLET <br />C.C. <br />E.P. <br />SD <br />CM <br />T <br />TV <br />MP <br />X-0 X-0 <br />CONCRETE WALL <br />CMU WALL <br />3 HR. RATED WALL/PARTY WALL <br />2 HR. RATED SHAFT WALL <br />1 HR. RATED PARTY WALL <br />1 HR. RATED CORRIDOR WALL <br />INTERIOR WALL W/ WOOD STUD W/ ONE <br />LAYER GYP. BD. ON EACH SIDE <br />SYMBOL DESCRIPTION DETAIL <br />14/A7.31 <br />3 /A7.31 <br />10 /A7.31 <br />7 /A7.31 <br />RENEWAL <br />DATE <br />RCHITE <br />CTDESNECIL A <br />A L IF ORNIA <br />FOETATSC <br />JOHNNY C. LU <br />C-30396 <br />6/30/2023 <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.Job No.: <br />Drawn: <br />Checked: <br />BID Date:411 EAST HUNTINGTON DRIVESUITE 308ARCADIA, CALIFORNIA 91006PHN: (626) 446-5300TAG design worksSHEET # <br />SHEET TITLE:200 N. CABRILLO, SANTA ANA, CA 92701ARCHITECT:PROJECT ADDRESS:THE MADISON3/28/2022 DD SET <br />4/22/2022 100% DD <br />1ST BUILDING DEPT SUBMITTAL 05-31-20225/31/2022 1ST PLAN CHECK <br />Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt <br />ENLARGED <br />UNIT PLANS <br />A5.231/4" = 1'-0"1PLAN-UNIT 2B-01 <br />1/4" = 1'-0"2PLAN-UNIT 2B-02 <br />1/4" = 1'-0"3PLAN-UNIT 2B-03 <br />REFER TO OVERALL PLANS FOR <br />EXTERIOR WALL CONFIGURATION REFER TO OVERALL PLANS FOR <br />EXTERIOR WALL CONFIGURATION <br />REFER TO OVERALL PLANS FOR <br />EXTERIOR WALL CONFIGURATION <br />Date Issues / Revisions: <br />GENERAL NOTES <br />XFLOOR PLAN KEY NOTES <br />LEGEND <br />1.SEE SHEET A3.0 : UNIT KITCHEN PLANS AND UNIT BATHROOM <br />PLANS FOR ALL DETAIL DIMENSIONS AND CLEARANCES. <br />2.LIGHTS TO BE CENTERED IN CEILING AREA WITHIN ROOM <br />UNLESS NOTED OTHERWISE. <br />3.ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT <br />SHALL BE KEPT AS TIGHT AS POSSIBLE TO FLOOR STRUCTURE <br />4.FOR FIRE BARRIER LOCATIONS PLEASE REFER TO THE <br />COMPOSITE FLOOR PLANS. <br />5.EVERY DWELLING MUST BE PROVDIED WITH SMOKE ALARM <br />DEVICES PER SECTION (907.2.1.0) -SEE PLANS FOR LOCATION AND <br />ELECTRICAL FOR WIRING. <br />6.OPERABLE PORTION OF ANY WINDOW MUST BE 3' MIN AWAY <br />FROM ANY EXHAUST VENT OR DUCT. EXHAUST DUCTS SHALL <br />TERMINATE A MIN. OF 3' FROM OPENINGS INTO THE BUILDING. <br />7.ALL FIRE RATED PARTITION WALLS SHALL BE UNINTERRUPTED. <br />INTERIOR WALLS SHOULD BE OVER RATED DRYWALL. <br />8.IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY WINDOW/ <br />DOOR R.O. FOR TYPES AND LOCATIONS PRIOR TO INSTALLATION. <br />9.WINDOWS IN SLEEPING ROOMS MUST MEET LABC EGRESS <br />REQUIREMENTS OF 5.7 SF OF OPENING WITH 20" CLEAR OPENING IN <br />WIDTH, 24" IN HEIGHT AND MAX. OF 44" SILL HEIGHT. IT IS THE <br />RESPONSIBILITY OF THE WINDOW SUPPLIER TO ENSURE THAT <br />WINDOWS COMPLY WITH THIS REQUIREMENT. <br />10.APARTMENT-UNIT ENTRY DOOR ASSEMBLIES AT CORRIDORS <br />SHALL BE EQUIPPED WITH GASKETS FOR SMOKE AND DRAFT <br />CONTROL. DOOR AND FRAME OF SUCH ASSEMBLIES SHALL BEAR AN <br />APPROVED LABEL SHOWING THE RATING FOLLOW BY THE LETTER "S", <br />NAME OF THE MANUF. AND THE I.D. OF THE LISTING SERVICE, ALONG <br />WITH A PEEP HOLE. <br />11.LOCATE THE SMOKE ALARM A MIN. 20 FEET FROM <br />PERMANENTLY INSTALLED COOKING APPLIANCE. 2019 CFC <br />907.2.10.8(NFPA 72 29.8.3.4) EXCEPTION 1-ALLOW IONIZATION SMOKE <br />ALARMS 10 FEET OR GREATER AWAY. EXCEPTION2-ALLOWS <br />PHOTOELECTRIC SMOKE GREATER THAN 6 FEET FROM PERMANENTLY <br />INSTALLED COOKING APPLIANCE WHERE THE KITCHEN OR COOKING <br />AREA AND ADJACENT SPACES HAVE NO CLEAR INTERIOR PARTITIONS <br />AND THE 10-FOOT DISTANCES WOULD PROHIBIT THE PLACEMENT OF A <br />SMOKE DETECTOR REQUIRED BY OTHER SECTIONS OF THE CODE. <br />SYMBOL DESCRIPTION <br />1 42" HT. BALCONY RAILING <br />2 BALCONY DECK WITH WATERPROOFING <br />3 MECHANICAL SHAFT <br />4 DOOR BUZZER MOUNTED 48" A.F.F. MAX. AND CONNECTED TO <br />PERMANENT WIRING(HARD WIRED) <br />5 STACKABLE FRONT LOADING WASHER AND DRYER, SELECT BY <br />OWNER. PROVIDE LOUVERED DOOR. <br />6 1-HR RATED PROTECTION AT INTERIOR POST/SHEAR PANEL <br />7 DISH WASHER UNDER COUNTERTOP <br />8 30" ELEC. IGNITION GAS RANGE <br />9 REFRIGERATOR <br />10 SINK & FAUCET, SEE PLUMBING DWG'S. <br />11 TOILET - SEE ACCESSIBILITY NOTE # 5. <br />12 30" DOUBLE SINK WITH CASEWORK <br />13 BATH TUB. SEE ACCESSIBILITY NOTE # 5. <br />14 VANITY SINK WITH COUNTERTOP AT 34" MAX. ABOVE FINISH <br />FLOOR. <br />15 SHOWER WITH FRAMELESS DOOR SYSTEM. 36" SHOWER <br />DOOR OPENING WITH TEMPERED GLASS. SHOWER FLOOR <br />WITH 1/2" PER FT. SLOPE TO DRAIN. SEE ACCESSIBILITY NOTE <br /># 5. PROVIDE A 2" MAX. THRESHOLD AND HAVE A BEVELED OR <br />SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 2 UNITS <br />HORIZONTAL. <br />SYMBOL DESCRIPTION <br />31 F.A.U. IN CEILING SPACE <br />32 DROP CEILING <br />33 WINDOW EXTERIOR SHADING DEVICE, WHERE OCCURS, SEE <br />ELEVATIONS. <br />34 WEEP SCREED/VENT SCREED AT EXTERIOR SOFFIT/BALCONY <br />UNIT PLAN CEILING KEYNOTES <br /> <br /> <br />City Council 29 – 110 11/19/2024