My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packet_2024-11-19
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Agenda Packet_2024-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 8:48:28 AM
Creation date
11/19/2024 8:40:58 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYPE D -FIRE WALL <br />A.F.F <br />TYPE D -UNIT DECK <br />A.F.F <br />TYPE G -INTERIOR STAIRS <br />A.F.F <br />TYPE G -TRASH ROOM <br />A.F.F <br />TYPE G -TRASH VESTIBULE <br />A.F.F <br />TYPE G -EXTERIOR RETAIL <br />A.F.F <br />TYPE G -BOOSTER PUMP ROOM <br />A.F.F <br />TYPE G -GARAGE <br />A.F.F <br />TYPE G -POOL DECK <br />A.F.F <br />TYPE U -ENTRY <br />A.F.F <br />TYPE U -UNIT DECK <br />A.F.F <br />6' - 0"8' - 0"7' - 0"8' - 0"3' - 0"7' - 0"3' - 6"7' - 0"6' - 0"7' - 0"8' - 0"7' - 0"3' - 0"7' - 0"3' - 6"7' - 0"3' - 0"6' - 8"6' - 0"7' - 0"6' - 0"7' - 8"8' - 6"24' - 5" <br />3' - 0"8' - 0"3' - 0"7' - 0"3' - 0"8' - 0"RENEWAL <br />DATE <br />RCHITE <br />CTDESNECIL A <br />A L IF ORNIA <br />FOETATSC <br />JOHNNY C. LU <br />C-30396 <br />6/30/2023 <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.Job No.: <br />Drawn: <br />Checked: <br />BID Date:411 EAST HUNTINGTON DRIVESUITE 308ARCADIA, CALIFORNIA 91006PHN: (626) 446-5300TAG design worksSHEET # <br />SHEET TITLE:200 N. CABRILLO, SANTA ANA, CA 92701ARCHITECT:PROJECT ADDRESS:THE MADISON3/28/2022 DD SET <br />4/22/2022 100% DD <br />1ST BUILDING DEPT SUBMITTAL 05-31-20225/31/2022 1ST PLAN CHECK <br />Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt <br />DOOR <br />SCHEDULE <br />A6.20 <br />DOOR SCHEDULE - COMMON DOORS <br />NUMBER LOCATION DIMENSION DOOR FRAME FIRE RATING STC RATING HARDWARE <br />GROUP <br />DETAIL REMARKS <br />WIDTH HEIGHT TYPE MATERIAL FINISH MATERIAL FINISH HEAD JAMB JAMB THRESHOLD <br />0' - 0" 0' - 0" <br />D-001 FIRE WALL 6' - 0" 8' - 0" <br />D-004 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />D-005 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />D-006 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />D-007 EXTERIOR EQUIP 3' - 0" 6' - 8" A HM P-SG HM P-SG NR 6/A-76.41 6/A-76.41 4/A-76.42 1,4,5,16 <br />D-008 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />D-009 TRASH VESTIBULE 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1 <br />D-010 BOOSTER PUMP ROOM 6' - 0" 7' - 0" C HM P-SG HM P-SG NR 6/A-76.41 6/A-76.41 4/A-76.42 4,5,27 <br />D-011 BOOSTER PUMP ROOM 6' - 0" 7' - 8" C HM P-SG HM P-SG NR 6/A-76.41 6/A-76.41 4/A-76.42 4,5,27 <br />D-012 POOL DECK 3' - 0" 8' - 0" Q GL P-SG VN P-SG NR 35 11/A-76.42 10/A-76.42 5 <br />G-001 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />G-002 INTERIOR STAIRS 3' - 6" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />G-003 TRASH ROOM 6' - 0" 7' - 0" C HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 1 <br />G-004 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />G-005 TRASH VESTIBULE 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1 <br />G-006 TRASH VESTIBULE 3' - 6" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1 <br />G-007 TRASH ROOM 8' - 0" 7' - 0" C HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 1 <br />G-008 INTERIOR STAIRS 3' - 0" 7' - 0" A HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 - 1,16 <br />G-009 TRASH ROOM 8' - 0" 7' - 0" C HM P-SG HM P-SG 90 MIN 6/A-76.41 6/A-76.41 1 <br />G-010 GARAGE 24' - 5" 8' - 6" <br />DOOR SCHEDULE - UNITS <br />NUMBER LOCATION DIMENSION DOOR FRAME FIRE RATING STC RATING HARDWARE <br />GROUP <br />DETAIL REMARKS <br />WIDTH HEIGHT TYPE MATERIAL FINISH MATERIAL FINISH HEAD JAMB JAMB THRESHOLD <br />U-1 ENTRY 3' - 0" 7' - 0" A HM P-SG HM P-SG 20 MIN 26 2/A-76.42 3/A-76.42 1/A-76.42 1,12, 25 <br />U-7 UNIT DECK 7' - 0" 8' - 0" D GL P-SG VN P-SG NR 5 <br />U-10 UNIT DECK 3' - 0" 8' - 0" Q GL P-SG VN P-SG NR 35 11/A-76.42 10/A-76.42 5 <br />1/4" = 1'-0" <br />DOOR LEGEND <br />GENERAL NOTE <br />A. EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. <br />B. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, <br />UNINTERRUPTED SURFACE. <br />C. ALL REMOVED (DEMOLISHED) DOORS TO BE RE-USED OR RELOCATED WHEN POSSIBLE. SEE PLAN <br />FOR RELOCATION NOTES. STORE ALL DOORS WITH FRAMES, TRIM AND HARDWARE UNTIL COMPLETION <br />OF THE WORK.. <br />D. A EXIT DOOR(S) SHALL BE A MIN. OF 3'-0" X 7'-0" WITH A MINIMUM SWING OF NINETY (90) DEGRESS. <br />WIDTH & HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH C.B.C. 1003.3.1 AND 1005.1. <br />E. CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING DOOR FRAME UNITS, SCHEDULED FOR NEW <br />DOORS, LOUVRES, PANELS ETC. <br />F. ALL NEW DOOR FRAMES TO BE BY 'TIMELY', FINISH AND COLOR TO MATCH EXISTING WITH SQUARE- <br />EDGED TRIM (NOT TAPERED). <br />G. PAINT ALL FRAMES, UNLESS OTHERWISE NOTED. <br />H.IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO <br />THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE <br />TO A POINT 3 INCHES (75MM) FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR. <br />J.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS (38N) FOR EXTERIOR AND <br />INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS <br />AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC <br />DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE <br />REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM <br />ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.72N), <br />PER SECTION 1133B.2.5 <br />K. IN ACCESSIBLE UNIT, SWINGING DOOR OR GATE SURFACES WITHIN 10 INCHES (254 MM) OF THE <br />FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH <br />SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. <br />L.BRAILLE SYMBOLS: CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS <br />ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH <br />(2.54 MM) ON CENTERS IN EACH CELL WITH 2/10 INCH (5.08 MM) SPACE BETWEEN CELLS. DOTS SHALL BE <br />RAISED A MINIMUM OF 1/40 INCH (0.635 MM) ABOVE THE BACKGROUND. ALL SIGNS AND IDENTIFICATION <br />SHALL COMPLY WITH TITLE 24, SECTION 1117B.5-1117B.5.10 <br />M.PROVIDE ROOM SIGNS FOR ALL ROOMS. SEE INTERIOR SIGN PROGRAM BY OTHERS. <br />N.NOT USED. <br />O.UNDERCUT DOORS ONLY AS REQUIRED PER MECHANICAL PLANS, OR AS OTHERWISE NOTED. <br />ACCESSIBILITY NOTES <br />DOOR SCHEDULE - STOREFRONT DOOR <br />NUMBER LOCATION <br />DIMENSION DOOR FRAME <br />FIRE RATING STC RATING <br />HARDWARE <br />GROUP <br />DETAIL <br />REMARKSWidth Height TYPE MATERIAL FINISH MATERIAL FINISH HEAD JAMB JAMB 2 THRESHOLD <br />S-1 3' - 0" 8' - 0" <br />Date Issues / Revisions: <br /> <br /> <br />City Council 29 – 121 11/19/2024
The URL can be used to link to this page
Your browser does not support the video tag.