My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packet_2024-11-19
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Agenda Packet_2024-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 8:48:28 AM
Creation date
11/19/2024 8:40:58 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3'-6".1'-7"2'-8 1/2".1'-7" 1'-0" <br />FLOOR <br />PIPE IN THE WALL <br />PER PLUMBING <br />FIRE HOSE VALVE <br />19"W x 19"H x 8 <br />1/2"D WALL <br />OPENING <br />CENTERLINE OF <br />PIPE EDGE OF WALL OPENINGRISER CLAMP <br />CABINET <br />EQUIPMENT <br />IDENTIFICATION <br />PER CBC 905.7.1 <br />ABS OR PVC CLOSE FLANGE SIZED TO <br />ACCOMMODATE DRAIN PIPE. CLOSET <br />FLANGE SECURED TO PLYWOOD <br />SUBFLOOR WITH STEEL SCREWS <br />TOPPING PER SPECIFICATIONS <br />PLYWOOD SUBFLOOR PER STRUCTURAL <br />MIN. 3/4" DEPTH HILTI CP 606 FLEXIBLE <br />FIRESTOP SEALANT <br />NOMINAL 4" MAX. DIAMETER ABS <br />OR PVC PIPE <br />NOTE: <br />DIAMETER OF OPENING TO BE MAX. 1/4" <br />LARGER THAN OUTSIDE DIAMETER OF PIPE <br />REFERENCE: UL SYSTEM NO. F-C-2263 <br />ROUND OR OVAL GAS <br />APPLIANCE B-VENT IN 1HR WALL <br />WALL ASSEMBLY <br />NO INSULATION PERMITTED IN <br />STUD & JOIST BAY WITH B-VENT <br />2 X WOOD STUDS WALL <br />FIRESTOP PLATE (PROVIDE TIGHT <br />FIT) ALL AROUND (FLOOR AND <br />CEILING LEVEL) <br />2X WOOD SILL PLATE CUT AWAY <br />FOR FULL WIDTH OF STUD BAY <br />FLOOR FRAMING PER <br />STRUCTURAL <br />PROVIDE 1" MIN. AIR SPACE TO ALL <br />COMBUSTIBLE MATERIALS <br />FIRE STOP SPACER NAILED TO <br />PLATE AT BOTH ENDS (FLOOR AND <br />CEILING LEVELS) <br />5/8" TYPE X GYPSUM BOARD EACH <br />SIDE TO PROVIDE ONE HOUR <br />ASSEMBLY <br />(2) 2X CONTINUOUS TOP PLATES, <br />CUT AWAY FOR FULL WIDTH OF <br />STUD BAY <br />NOTES: <br />1. PROVIDE WALL STUD SIZE TO FIT <br />VENT AND ALLOW 1" CLEAR <br />ANNULAR SPACE AROUND VENT TO <br />COMBUSTIBLE MATERIALS <br />2. INSTALL VENT PER <br />MANUFACTURER'S UL LISTING AND <br />INSTALLATION INSTRUCTIONS-UL <br />MH 5102 <br />MECHANICAL DUCT <br />SHEET METAL PER <br />MECHANICAL <br />DRAWINGS AT <br />ASSEMBLY <br />SHEET METAL <br />EYEBROW VENT LAP <br />BUILDING PAPER PER <br />WATERPROOFING <br />DRAWINGS <br />FIRE CAULKING <br />TWO (2) LAYERS 5/8" TYPE <br />'X' GYPSUM WALLBOARD <br />LINED JOIST BAY AT <br />MECHANICAL VENT <br />VERIFY WITH MANUFACTURER10" WIDE X 25" HIGH CLEAR1' - 4"EXTERIOR CEMENT PLASTER OVER LATH OVER <br />WATERPROOFING PER WATERPROOFING <br />DRAWINGS (WHERE OCCURS) <br />CAULK CABINET TO OPENING AT ALL FOUR SIDES <br />SEMI-RECESSED FIRE EXTINGUISHER CABINET <br />SEE SPECIFICATIONS FOR REQUIREMENTS <br />5/8" TYPE 'X' GYPSUM BOARD <br />5/8" TYPE 'X' GYPSUM BOARD, NO JOINTS <br />WITHIN 8" OF FRAMED OPENING <br />1" THICK SHAFT LINER LAMINATE BOTH SIDES <br />OVER ENTIRE CONTACT SURFACE. <br />1/2" GYPSUM BOARD MINIMUM LAMINATE OVER <br />ENTIRE CONTACT SURFACE <br />FIRE EXTINGUISHER PER PLANS <br />FULL 2X4 BLOCKING -BOTH <br />SIDES, TOP AND BOTTOM <br />"J" MOLDING BOTH SIDES, TOP AND BOTTOM. <br />WHEN CABINET IS LOCATED LESS THAN 15'-0" <br />FROM FACE OF PROTECTIVE OVERHANG, <br />USE GI SHEET METAL DRIP FLASHING AT <br />HEAD CONDITION. <br />2X OR 3X STUDS AT 16" O.C. <br />2 1/4" MIN. <br />GA FILE NO. WP 1311 <br />SOLID GYPSUM WALL <br />PIPE IN THE WALL PER <br />PLUMBING <br />1 LAYER OF 5/8" <br />GYPSUM BOARD <br />WALL OPENING REQUIRED <br />1'-7" <br />2x4 WOOD STUD <br />WALL <br />2x6 WOOD STUD <br />WALL <br />CABINET PER FIRE <br />SPRINKLER <br />DRAWINGS <br />8" MIN.1'-8 1/4" 1'-7" <br />PLYWOOD SHEATING PER <br />STRUCTURAL <br />DRYER DUCT PER MECHANICAL <br />2X BLOCKING <br />DECK FRAMING PER STRUCTURAL <br />5/8" TYPE X GYPSUM BOARD <br />LINED JOIST BAY AT DRYER <br />VENT, SIM. TO DETAIL <br />J-MOLD AROUND OPENING <br />PAINT VISIBLE PORTION <br />OF DUCT BLACK <br />EXTERIOR CEMENT <br />PLASTER OVER METAL LATH <br />GRILLE PER <br />MECHANICAL <br />DRAWINGS <br />SHEET METAL GALVANIZED ROOF JACK <br />LAP ROOFING MEMBRANE OVER AND <br />UNDER BASE TO PROHIBIT WATER <br />ENTRY <br />ROOF ASSEMBLY PER DETAIL <br />2X BLOCKING BETWEEN <br />JOIST MEMBERS TYPICAL <br />26 GAUGE SHEET METAL DUCT <br />EXTERIOR PLASTER OVER MET. LATH AND <br />BUILDING PAPER PER WATERPROOFING <br />DRAWINGS3/4".1/2".PARAPET HEIGHT FROM <br />TOP OF LOW ROOF <br />SHEATHING (ROOF <br />DATUM) <br />STRUCTURAL PLYWOOD AS REQ'D, <br />REFER TO STRUCT. DWGS. <br />EXT. CEM. PLAS. OVER MET. LATH <br />AND BLDG PAPER <br />T.O. ROOF SHEATHING <br />FIRE CAULKING <br />SOLID BLOCKING ON ALL FOUR SIDES <br />AROUND DUCT <br />SHOWER PER PLANS <br />(2) 5/8" TYPE 'X' GYPSUM BOARD FOR 1 HOUR WALL <br />DETAIL REQUIREMENTS PER C.B.C. TABLE <br />721.2.1.4(2) <br />FULL 2 X BLOCKING BETWEEN <br />JOISTS TO PROVIDE DRYWALL <br />NAILINGSEE PLUMBING PLANS <br />WALL AS OCCURS <br />FOR PENETRATION OF <br />BLOCKING, SEE <br />CAST IRON WASTE LINE <br />AT PENETRATION OF <br />ONE HOUR ASSEMBLY <br />PER PLUMBING PLANS <br />CREMCO ICP/ICP NO HUB COUPLING. <br />UPC APPROVED FOR CAST IRON TO <br />PLASTIC CONNECTIONS IN CONCEALED <br />SPACES <br />PVC WASTE TRAP PER <br />PLUMBING PLANS <br />ALL PLASTIC TO PLASTIC PIPE <br />CONNECTIONS TO BE GLUE WELDED <br />DOUBLE PLYWOOD FLOOR CONSISTING OF MINIMUM 1/2" <br />(15/32") WOOD STRUCTURAL PANELS WITH EXTERIOR GLUE <br />OVER 5/8" (19/32") WOOD STRUCTURAL PANELS OR SUBFLOOR <br />OF (1) LAYER 1-1/8" T&G WOOD STRUCTURAL PANELS. <br />PER C.B.C. TABLE 720.1(3) 13.1.4 <br />AX.XX <br />-VERIFY WITH MANUFACTURER10" WIDE X 25" HIGH CLEAR1' - 4"EXTERIOR CEMENT PLASTER OVER LATH <br />OVER WATERPROOFING PER <br />WATERPROOFING DRAWINGS (WHERE <br />OCCURS) <br />CAULK CABINET TO OPENING AT <br />ALL FOUR SIDES <br />SEMI-RECESSED FIRE EXTINGUISHER <br />CABINET SEE SPECIFICATIONS FOR <br />REQUIREMENTS <br />2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD <br />2 LAYERS 5/8" TYPE 'X' GYPSUM <br />BOARD, NO JOINTS WITHIN 24" OF <br />FRAMED OPENING <br />1" THICK SHAFT LINER LAMINATE BOTH <br />SIDES OVER ENTIRE CONTACT SURFACE. <br />1/2" TYPE 'X' GYPSUM BOARD MINIMUM <br />LAMINATE OVER ENTIRE CONTACT <br />SURFACE <br />FIRE EXTINGUISHER PER PLANS <br />FULL WIDTH BLOCKING -BOTH SIDES, <br />TOP AND BOTTOM <br />"J" MOLDING BOTH SIDES, TOP AND <br />BOTTOM. WHEN CABINET IS LOCATED <br />LESS THAN 15'-0" FROM FACE OF <br />PROTECTIVE OVERHANG, USE GI SHEET <br />METAL DRIP FLASHING AT HEAD <br />CONDITION. <br />2X OR 3X STUDS AT 16" O.C.GA FILE NO. WP 1841 <br />SOLID GYPSUM WALL <br />1 HOUR RATED BOX <br />MODEL PER PLUMBING <br />DRAWINGS TO BE <br />INSTALLED IN <br />ACCORDANCE WITH W- <br />L-7129 AND <br />MANUFACTURERS <br />INSTRUCTIONS. <br />PIPING PER PLUMBING / <br />MECHANICAL DRAWINGS <br />INSULATION PER SCHEDULE <br />5/8" TYPE X GYPSUM <br />WALLBOARD <br />2X SOLID WOOD BLOCKING <br />FIRE RATED ACCOUSTICAL <br />SEALANT <br />TOPPING PER <br />SPECIFICATION <br />S <br />NOMINAL 1 1/2" MAX. <br />SCHEDULE 40 ABS OR PVC <br />PIPE AND DRAIN FITTINGS <br />CEMENTED TOGETHER AND <br />PROVIDED WITH ABS OR <br />PVC BATHTUB <br />WASTE/OVERFLOW <br />FITTINGS. <br />PLYWOOD SUBFLOOR <br />PER STRUCTURAL <br />3/4" THICK PLYWOOD PATCH <br />SIZED TO OVERLAP <br />MINIMUM 2" BEYOND EACH <br />EDGE OF RECTANGULAR <br />OPENING. TWO PIECES <br />POSITIONED AROUND DRAIN <br />PIPING WITH CUT EDGES <br />TIGHTLY BUTTED, AND <br />SCREW ATTACHED TO <br />UNDERSIDE OF SUBFLOOR <br />WITH 1 1/4" LONG STEEL <br />SCREWS (SPACED MAXIMUM <br />6" O.C.). (SEE NOTE#3 <br />BELOW) <br />MIN. 5/8" DEPTH HILTI CP 606 <br />FLEXIBLE FIRESTOP <br />SEALANT FLUSH WITH BOTH <br />SURFACES OF PLYWOOD. <br />NOTES: <br />1. MAX. SIZE OF OPENING = 12"X8" <br />2. ANNULAR SPACE BETWEEN DRAIN PIPING AND PATH = MIN. 0", MAX. 1" <br />3. AS ALTERNATE TO PLYWOOD, 5/8" THICK GYPSUM WALL BOARD MAY BE USED. <br />REFERENCE: UL SYSTEM NO. F-C-2262 <br />2" MIN. <br />1" MAX. <br />WALL PER <br />PLANS <br />2X FLOOR JOISTS <br />RECESSED DMF RATED <br />LIGHT FIXTURE ZERO <br />CLEARANCE RATED <br />BLOCK IN AREA <br />AROUND LIGHT <br />FIXTURE LOCATION, <br />THEN WRAP AREA W/ <br />(2) 5/8" TYPE 'X' GYPSUM <br />BOARD <br />5/8" TYPE "X" <br />GYPSUM BOARD <br />FLOOR ASSEMBLY <br />FIRE RATED <br />ACOUSTICAL SEALANT <br />REQUIRED AT BLOCK- <br />IN TO CEILING BOARD <br />LIGHT FIXTURE RATING TO <br />MATCH ADJACENT FLOOR <br />CEILING ASSEMBLY. <br />FIRE RATED ACOUSTICAL <br />SEALANT <br />CONTRACTOR TO PROVIDE <br />SOUND TESTING RESULTS TO <br />ACCOUSTICAL CONSULTANT <br />PRIOR TO INSTALLATION <br />TRIM PER SPECIFICATIONS <br />2X FLOOR <br />JOISTS <br />RECESSED DMF RATED <br />LIGHT FIXTURE ZERO <br />CLEARANCE RATED <br />BLOCK IN AREA <br />AROUND LIGHT <br />FIXTURE LOCATION, <br />THEN WRAP AREA W/ <br />(2) 5/8" TYPE 'X' GYP. BD. <br />5/8" TYPE 'X' MOLD <br />RESISTANT GYP. BD. <br />7/8" EXTERIOR <br />PLASTER OVER METAL <br />LATH WHERE OCCURS <br />AT EXTERIOR <br />CONDITION <br />2 1/2" METAL STUD <br />HVAC DUCT, PER <br />TENANT IMPROVEMENT <br />FIRE CAULKING PER <br />SPECIFICATIONS <br />2 1/2" METAL STUDS AT <br />16" O.C. <br />STRUCTURAL SLAB, SEE <br />STRUCTURAL <br />DRAWINGS <br />PENETRATING ITEM <br />2X OR 3X STUDS PER STRUCTURAL AT <br />16" O.C. MAXIMUM <br />WHERE WASTE AND WATER <br />SUPPLY PIPING IS REQUIRED IN <br />INTERIOR PARTITION WALLS, THE <br />PARTITION WALL SHALL BE <br />CONSTRUCTED WITH THE <br />FOLLOWING REVISIONS: <br />1. SNUGLY FITTING BETWEEN THE <br />STUDS WHERE PIPING OCCURS. <br />WALL TYPE PER PLAN <br />NOTE: <br />APPLY PLYWOOD PER STRUCTURAL <br />DRAWINGS TO STUDS PRIOR TO <br />APPLICATION OF FINISHES <br />PROVIDE 2x JOIST BAY BLOCK OR <br />5/8" TYPE "X" GYPSUM BOARD TO <br />ISOLATE WALL AND FLOOR <br />CAVITIES. <br />IF 2x BLOCKING ISOLATOR IS <br />USED A DRAFT STOP MUST BE <br />INSTALLED. PLYWOOD OR <br />INSULATION IS ACCEPTABLE <br />IF GYPSUM BOARD ISOLATOR IS <br />USED PENETRATIONS MUST BE <br />FIRE CAULKED <br />VERIFY SPECIAL PLAN CONDITIONS <br />0' - 2" TYP. <br />0' - 2 1/2" <br />PROVIDE 5/8" TYPE 'X' <br />GYPSUM BOARD <br />PROTECTION OF ALL <br />WALL ASSEMBLIES <br />PENETRATED <br />AIR HANDLER PER <br />MECHANICAL PLANS IN <br />DROPPED CEILING SPACE <br />FOR RETURN AIR ROUTING <br />AND ADDITIONAL <br />INFORMATION, SEE <br />MECHANICAL PLANS <br />OPENING <br />2 1/2" METAL STUD <br />1 5/8" METAL STUD <br />BATHROOM <br />LIGHT FIXTURE PER <br />ELECTRICAL DWGS. <br />NOTE: <br />WHEN LIGHT FIXTURE IS LOCATED IN A RATED CEILING A BOXED OUT AREA <br />WRAPPED WITH 5/8" TYPE 'X' GYP. BOARD TO MATCH ADJ. FIRE RATING IS <br />REQUIRED <br />1 HR2 1/2" METAL STUD <br />7/8" EXTERIOR PLASTER AS <br />OCCURS <br />5/8" TYPE 'X' GYP. <br />BD. <br />FLOOR ASSEBMLY <br />FIRE RATED ACOUSTICAL SEALANT <br />FLEXIBLE HVAC DUCT <br />WRAP JOIST BAY WITH ONE <br />LAYER 5/8" TYPE X GYPSUM <br />WALLBOARD <br />5/8" TYPE 'X' GYPSUM BOARD AT <br />FLOOR JOISTS <br />2X FLOOR JOIST <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.Job No.: <br />Drawn: <br />Checked: <br />BID Date:411 EAST HUNTINGTON DRIVESUITE 308ARCADIA, CALIFORNIA 91006PHN: (626) 446-5300TAG design worksSHEET # <br />SHEET TITLE:200 N. CABRILLO, SANTA ANA, CA 92701ARCHITECT:PROJECT ADDRESS:THE MADISON3/28/2022 DD SET <br />4/22/2022 100% DD <br />1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022 Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt <br />PENETRATION <br />ASSEMBLIES <br />A7.531 1/2" = 1'-0"1STANDPIPE AT CORRIDOR ELEVATION <br />1 1/2" = 1'-0"2WATER CLOSET WASTE LINE <br />1 1/2" = 1'-0"3B-VENT ASSEMBLY DETAIL <br />1 1/2" = 1'-0"4MECHANICAL VENT AT EXTERIOR WALL <br />3" = 1'-0"51-HR RECESS FOR FIRE EXTINGUISHER <br />1 1/2" = 1'-0"6STANDPIPE AT CORRIDOR PLAN <br />3" = 1'-0"8EXHAUST DUCT AT DECK <br />1 1/2" = 1'-0"9EXHAUST FAN ROOF PENETRATION <br />1 1/2" = 1'-0"7SHOWER WASTE TRAP PENETRATION <br />3" = 1'-0"102-HR RECESS FOR FIRE EXTINGUISHER <br />1 1/2" = 1'-0"111-HR RATED BOX <br />1 1/2" = 1'-0"12BATHTUB WASTE TRAP DETAIL <br />1 1/2" = 1'-0"13RECESSED CAN LIGHT AT UNIT <br />1 1/2" = 1'-0"14FIRE-RATED LIGHT FXTR IN RATED CLG <br />1 1/2" = 1'-0"15RECESSED CAN LIGHT AT CORRIDOR <br />3" = 1'-0"16RETAIL SHAFT TERMINATION <br />1 1/2" = 1'-0"17FIRE STOPPING AT DUCT PNTRTNS <br />1 1/2" = 1'-0"18RETURN AIR LOCK BLOCKOUT <br />1 1/2" = 1'-0"19RECESSED LIGHT FIXTURE <br />1 1/2" = 1'-0"201-HR HORIZONTAL DUCT CHASE <br />Date Issues / Revisions: <br /> <br /> <br />City Council 29 – 136 11/19/2024
The URL can be used to link to this page
Your browser does not support the video tag.