My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2025
>
01/21/2025
>
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 4:50:22 PM
Creation date
1/21/2025 3:12:07 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
18
Date
1/21/2025
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: 25-6030 <br />TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br />AVENUE <br />14. Submit a sewer overflow emergency response plan. The plan will dictate backup <br />pumping plans, spill containment procedures, spill recovery procedures and <br />emergency call out phone numbers. <br />Provision shall be made by the Contractor for the collection of sewage from cutoff lateral <br />sewers. Lateral sewers shall be reconnected to the main before the termination of every <br />working day. <br />The text of Subsection 306-1.6 of the Standard Specifications is hereby deleted and <br />replaced with the following: <br />Pipe shall be measured along the longitudinal axis between the ends as laid and <br />shall include the actual pipe in place. <br />6.10 POLYVINYL CHLORIDE (PVC) SEWER PIPE <br />Installation and construction of PVC sewer main shall conform to all applicable provisions <br />of the ASTM D2321-05 (or later) "Underground Installation of Thermoplastic Pipe for <br />Sewers and Other Gravity Flow Applications," Standard Specifications and these Special <br />Provisions and the construction plans. <br />Where indicated on the plans, sanitary sewer pipe shall be Polyvinyl Chloride (PVC,) sewer <br />pipe with compression joints conforming to Subsection 207-8 of the Standard <br />Specifications. <br />Underground conduit construction shall conform to all applicable Subsections of Section <br />306 of the Standard Specifications, the Standard Plans and these Special Provisions. <br />PVC sewer pipe shall be manufactured by JM Eagle or approved equivalent. <br />PVC gravity sewer pipe and fittings shall conform to ASTM D3034 for diameters from 4" <br />- 15", and ASTM F679 for 18" - 24", with integral bell gasket joints. Rubber gaskets shall <br />be factory installed and conform to ASTM F477. <br />Pipe shall be made of PVC plastic having a cell classification of 12454B or 12364B as <br />defined in ASTM D1784 and shall have SDR of 26 and minimum pipe stiffiiess of 115 psi <br />according to ASTM Test D2412. <br />Pipe shall be installed in compliance with ASTM D2321. Bedding material shall provide <br />adequate and uniform support under the pipe. <br />Pipe shall not be stored in direct sunlight. Pipe stored outdoors shall be protected from the <br />natural elements by covering it with opaque material such as canvas. The covering shall <br />be placed in such a way as to allow adequate air circulation between the cover and the pipe. <br />Discolored pipe will not be allowed. <br />M <br />
The URL can be used to link to this page
Your browser does not support the video tag.