Laserfiche WebLink
O RAIIV <br />O �r <br />GENERAL NOTES <br />1. ALL WORK SHOWN HEREON SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THE AGC/APWA <br />STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (CURRENT EDITION) AND SUPPLEMENTAL STANDARD <br />PROVISIONS ISSUED BY AND FOR USE IN THE CITY OF SANTA ANA. <br />2. CONTRACTOR SHALL COMPLY WITH STANDARD PLAN NO. 1160. REFER TO <br />https: //www.santo-ano.org/sites/default/files/Documents/1160-st.pdf. COPIES ARE AVAILABLE AT THE PUBLIC <br />WORKS COUNTER. <br />3. WITHIN 72-HOURS AFTER FINAL SURFACING IS PLACED, ALL MANHOLE AND VALVE BOX FRAMES AND COVERS SHALL <br />BE ADJUSTED BY THE DEVELOPER TO FINISH GRADE. THIS IS TO BE DONE PRIOR TO PLACING SEAL COAT. <br />4. WHEN CONSTRUCTION OF ASPHALT CONCRETE (AC) PAVEMENT INCLUDES REPLACEMENT OF PAVEMENT OVER <br />TRENCHES, PATCHES OR CUTS OR AN AC OVERLAY, PAVEMENT SHALL BE COVERED WITH PENETRATION TYPE <br />ASPHALT EMULSION (0.07 GALLONS PER SQUARE YARD) AFTER STREET PAVEMENT HAS BEEN CLEANED. FOG SEAL <br />COAT IS NOT REQUIRED FOR CONSTRUCTION OF NEW STREETS OR WIDENING OF EXISTING STREETS. <br />5. FEATHER AC WHERE MEETING EXISTING PAVEMENT. FEATHER TO LANE LINE OR A MINIMUM OF 10 FEET OR AS <br />DIRECTED BY THE CITY ENGINEER. <br />6. THE ENGINEER FOR THE SUBDIVIDER SHALL PROVIDE HUBS IN THE STREET FOR FINISHED SUBGRADE AND FINISHED <br />GRADE AT THE CROWN, AT ALL POINTS WHERE ELEVATIONS ARE SHOWN ON THE PLANS AND AT ANY ADDITIONAL <br />POINTS REQUIRED BY THE CITY ENGINEER. <br />7. AT THE TIME OF COMPACTING THE BASE SOIL AND PREPARING SUBGRADE, IF THE MOISTURE CONTENT IS SUCH THAT <br />THE SPECIFIED RELATIVE COMPACTION CANNOT BE OBTAINED OR THE SUBGRADE IS YIELDING, THE FOLLOWING <br />REMEDIAL ACTION SHALL BE PROVIDED: <br />A. REMOVE EXCESS MOISTURE BY SCARIFYING AND AERATING, OR <br />B. EXCAVATE UNSTABLE AREAS AND BACKFILL WITH SUITABLE MATERIAL OR BASE, OR <br />C. INCREASE THE AGGREGATE BASE SECTION, OR <br />D. STABILIZE THE BASEMENT SOIL WITH SUITABLE ADDITIVES, OR <br />E. PROVIDE AN ALTERNATE METHOD SUITABLE TO THE CITY ENGINEER. <br />8. WATER MAINS AND SERVICES ARE TO BE INSTALLED BY THE DEVELOPER AFTER THE CURB AND GUTTER IS <br />CONSTRUCTED AND BEFORE THE BASE UNDER THE AC SURFACING IS LAID. CONTACT WATER DIVISION SUPERVISOR AT <br />(714) 647-3343 TO ARRANGE SCHEDULING FOR WATER SYSTEM WORK BY THE CITY. <br />9. THE SUBDIVIDER SHALL RELOCATE ANY EXISTING PUBLIC UTILITIES LOCATED IN A DEDICATED RIGHT-OF-WAY, AS <br />REQUIRED BY THE CITY. <br />10. PERMIT NOTE - NO PERMIT WILL BE ISSUED FOR INSTALLATION OF UNDERGROUND UTILITY LINES UNTIL SAID UTILITY <br />LINES ARE SHOWN ON THE STREET IMPROVEMENT PLANS AND THEIR LOCATIONS ARE CERTIFIED BY THE PRIVATE <br />ENGINEER AND APPROVED BY THE CITY. <br />11. VCP SEWER CONNECTIONS ARE TO BE CONSTRUCTED FROM SEWER MAINS TO THE PROPERTY LINE. THE DEVELOPER IS <br />TO FURNISH THE CITY WITH THE LOCATION OF EACH CONNECTION. ALL SEWER LATERALS ARE TO BE REFERENCED ON <br />CURB. <br />12. ALL VCP JOINTS SHALL BE PLASTIC MECHANICAL COMPRESSION JOINTS OR BANDSEALS. <br />13. IT SHALL BE THE RESPONSIBILITY OF THE SEWER CONTRACTOR TO EXPOSE ALL JOIN POINTS TO THE EXISTING SEWER <br />AND TO HAVE THE LOCATION AND ELEVATION VERIFIED PRIOR TO ANY SEWER STAKES BEING FURNISHED. <br />14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL FLOW LINE ELEVATIONS AT ALL SEWER <br />MANHOLES VERIFIED PRIOR TO ANY PIPE BACKFILL. "AS BUILT" FLOW LINE ELEVATIONS ARE TO BE SUBMITTED TO <br />THE CITY PRIOR TO ANY PAVING. <br />15. CALL UNDERGROUND SERVICE ALERT AT (800) 422-4133 AT LEAST 48 HOURS (TWO WORKING DAYS) PRIOR TO ANY <br />EXCAVATION WHICH MAY DAMAGE OR INTERRUPT THE SERVICE OF ANY UNDERGROUND UTILITY LINE. <br />16. USE FULL -DEPTH HEADER FOR VERTICAL FACES OF PCC CONSTRUCTION. <br />17. ANY PERMANENT BARRICADE OR SAFETY SIGN OMITTED ON THE PLANS AND CONSIDERED NECESSARY BY THE CITY <br />SHALL BE INSTALLED BY THE DEVELOPER AT NO COST TO THE CITY. <br />18. STREET LIGHTING- BEFORE ANY ELECTRICAL CABLE OR CONDUIT IS PLACED FOR STREET LIGHTS, THE LOCATIONS FOR <br />THE PROPOSED STREET LIGHTS ARE TO BE VERIFIED BY THE CONSTRUCTION INSPECTOR AT (714) 647-5074 AFTER <br />THESE LOCATIONS HAVE BEEN MARKED OUT AS SHOWN ON THE IMPROVEMENT PLANS BY THE <br />DEVELOPER/CONTRACTOR. <br />19. CLEANUP AND DUST CONTROL - THE CONTRACTOR SHALL KEEP THE WORKSITE CLEAN AND FREE FROM RUBBISH AND <br />DEBRIS AT THE END OF EVERY WORKING DAY AND PROTECT EXISTING IMPROVEMENTS PER SECTION 7-9 OF THE <br />STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION. <br />20. CONTACT TREE SECTION SUPERVISOR AT (714) 647-3337 BEFORE INSTALLING ANY TREES. <br />21. TO OBTAIN A PERMIT TO ACCESS WATER FROM A FIRE HYDRANT, CONTACT THE CITY YARD AT (714)647-3380. <br />Underground Service Alert <br />• of Southern California <br />TWO WORKING DAYS <br />BEFORE YOU DIG <br />Know what's below. <br />Cal before you dig. CAL aFUE �w ❑G www.DigAlert.org <br />NOTICE TO CONTRACTOR <br />PURSUANT TO ASSEMBLY BILL 4216 NO EXCAVATION PERMIT <br />IS VALID UNLESS THE CONTRACTOR CONTACTS AND OBTAINS <br />A DIG ALERT TICKET NUMBER. CALL 811 AT LEAST TWO <br />WORKING DAYS PRIOR TO COMMENCING EXCAVATION. <br />FI LE N 0.: <br />Q, NUMBER DATE INITIALS <br />/O <br />0 ZIAI nA NN _j <br />A A <br />OFFSITE STREET IMPROVEMENT PLANS <br />S. ROSEWOOD AVE. AND <br />W. SEGERSTROM AVE. <br />SADDLEBACK HIGH SCHOOL <br />2802 S FLOWER ST. <br />SANTA ANA, CA 92707 <br />LOCATION MAP N <br />(NOT TO SCALE) <br />PRIVATE ENGINEER'S NOTICE TO CONTRACTOR <br />ABBREVIATIONS <br />1. PRIVATE AND PUBLIC UTILITIES, IF SHOWN, REFLECT AVAILABLE RECORD DATA. THE CONTRACTOR <br />AB <br />AC <br />AGGREGATE BASE <br />ASPHALT CONCRETE PAVEMENT <br />SHALL BE RESPONSIBLE FOR LOCATING ALL LINES AFFECTING THIS WORK AND FOR ANY DAMAGE OR <br />ASPH <br />ASPHALT PAVING <br />PROTECTION TO THESE LINES. PRIOR TO STARTING CONSTRUCTION OF THIS PROJECT, THE <br />BC <br />BEGIN CURVATURE <br />CONTRACTOR SHALL UNCOVER ALL EXISTING UTILITY LINES AFFECTING THIS WORK AND VERIFY THE <br />BCR <br />BEGIN CURB RETURN <br />ELEVATIONS OF SAID UTILITY LINES. <br />BLVD <br />BM <br />BOULEVARD <br />BENCH MARK <br />2. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING ANY WORK SHOWN ON OR RELATED TO <br />BOP <br />BOF <br />BOTTOM OF PIPE <br />BOTTOM OF FOOTING <br />THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE <br />BEGIN VERTICAL CURVATURE <br />PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL <br />CB <br />CB <br />CATCH BASIN <br />COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S. DEPARTMENT OF <br />(L <br />CENTERLINE <br />LABOR, WITH THE "CONSTRUCTION SAFETY ORDERS" OF THE STATE OF CALIFORNIA DEPARTMENT OF <br />CONST <br />CONSTRUCT <br />INDUSTRIAL REGULATIONS AND WITH CALTRANS AREA TRAFFIC CONTROL HANDBOOK (WATCH). <br />CR <br />CT <br />CURB RETURN <br />COURT <br />HOWEVER, THE CONSTRUCTION ENGINEER AND THE CITY OF SANTA ANA SHALL NOT BE RESPONSIBLE <br />CL <br />CENTERLINE <br />IN ANY WAY FOR SAID COMPLIANCE BY THE CONTRACTOR OR ANY SUBCONTRACTORS. <br />DW <br />DOMESTIC WATER <br />D/W <br />DRIVEWAY <br />3. FURTHERMORE, THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE <br />SDMH <br />STORM DRAIN MANHOLE <br />CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL <br />DR <br />(E) <br />DRIVE <br />EXISTING <br />PERSONS AND PROPERTY THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE <br />E'LY <br />EASTERLY <br />LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND <br />E <br />EAST <br />HOLD THE OWNER, ENGINEER, AND THE CITY OF SANTA ANA HARMLESS FROM ANY AND ALL <br />EC <br />END CURVATURE <br />LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, <br />ECR <br />END CURB RETURN <br />EXCEPTING FOR LIABILITY ARISING FROM THE SALE NEGLIGENCE OF THE OWNER, THE ENGINEER, OR <br />EG <br />E <br />EDGE OF GUTTER <br />ELEVATION <br />THE CITY OF SANTA ANA. <br />EOC <br />EDGE OF CONCRETE <br />EOP <br />EDGE OF PAVEMENT <br />ESMT <br />EASEMENT <br />EVC <br />END OF VERTICAL CURVATURE <br />FG <br />GRADE <br />CERTIFICATION OF THE PRIVATE ENGINEER <br />FL <br />F ON WLD <br />FS <br />FINISHED SURFACE <br />THE UNDERSIGNED CIVIL ENGINEER HEREBY CERTIFIES THAT THE UTILITY LOCATIONS (GAS, ELECTRICAL, <br />FW <br />FIRE PROTECTION SERVICE WATER <br />TELEPHONE, PRIVATE WATER, CTV, ETC.) SHOWN ON THESE PLANS DIRECTLY REFLECT UTILITY COMPANY <br />GB <br />GRADE BREAK <br />LAYOUTS. <br />GR <br />GRATE <br />HP <br />HIGH POINT <br />INV <br />INVERT <br />LF <br />LINEAR FEET <br />LIP <br />LIP OF GUTTER <br />RCE NO. 68369 <br />LP <br />LOW POINT <br />LT <br />LEFT <br />08/17/2021 <br />KATHEREEN M. SHINKAI DATE <br />REVISIONS REFERENCES <br />DESCRIPTION APPROVED INSTALLED BENCHMARK NO.: OCS 1 E-104-75 ELEV.: 126.92' NAVD88 <br />@ASIS OF BEARINGS: THE BASIS OF BEARING FOR THIS SURVEY IS BASED ON THE CALIFORNIA SYSTEM (CCS83), ZONE 6, NAD83, <br />OCS (2007.00) EPOCH ADJUSTMENT, AS DETERMINED LOCALLY BY A LINE BETWEEN CONTINUOUS GLOBAL POSITIONING STATIONS <br />(CGPS) 'SACY AND 'OEOC" BEING N80.43-39"E AS DERIVED FROM THE COORDINATES PUBLISHED AND ON FILE IN THE OFFICE OF <br />THE ORANGE COUNTY SURVEYOR. <br />HORIZONTAL DATUM: COORDINATES SHOWN ARE BASE ON THE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS83), ZONE VI, <br />NAD83 2007.00 EPOCH ADJUSTMENT. ALL DISTANCES SHOWN ARE GRID, UNLESS OTHERWISE NOTED. MULTIPLY GRID DISTANCES BY <br />1.00001963 TO OBTAIN A GROUND DISTANCE. ALL DISTANCES ARE BASED ON THE U.S. SURVEY FOOT. <br />CONSTRUCTION COMPLETED: <br />/O EN M. q! <br />m <br />R.C.E. 68369 <br />* XP. 9 25 <br />\T9T C 1 V <br />F OF CA��F� <br />MAX <br />MH <br />MIN <br />N <br />WILY <br />N TS <br />OC <br />OC* <br />()W <br />PA <br />P /L <br />POC <br />PRC <br />PVC <br />R <br />RCP <br />RIM <br />RT <br />R/W <br />S <br />S'LY <br />SCO <br />SD <br />SF <br />SHT <br />STA <br />STD <br />SMH <br />SPPWC <br />SWPPP <br />TC <br />TG <br />TOF <br />TOP <br />TW <br />TYP <br />U.N.O. <br />W <br />W'LY <br />WM <br />WARNER AVE. <br />W. SEGERSTROM <br />AVE. <br />v <br />w <br />� <br />z <br />MACARTHUR <br />af <br />0° <br />Vi <br />SITE SYMBOLS <br />SYM, DESC. <br />LEGEND <br />SYM. <br />DESC. DET. <br />PROPOSED FIRE HYDRANT <br />02/ <br />SAWCUT JOINT 9 <br />_ <br />�- <br />EXISTING TREE <br />------- <br />-� 021 <br />EXPANSION JOINT 9�. <br />PROTECT IN PLACE <br />__�___ <br />O <br />EXISTING MANHOLE <br />- - - - <br />LIMIT OF WORK_ <br />� 0 <br />EXISTING ELECTRICAL <br />- <br />(E)PA <br />_T- <br />EXISTING PLANTING AREA <br />UTILITY_ <br />EXISTING SIGN <br />--W-- <br />WATERUTILITY <br />EXISTING PALM TREE � �^ <br />- - G- - <br />GAS UTILITY <br />PROTECT IN PLACE <br />__ <br />i -r <br />EXISTING WATER <br />__S__ <br />�W0 _UTILITY <br />_ _ __ <br />_- <br />SEWER UTILITY _ <br />EXISTING STREET <br />--E-- <br />ELECTRICAL UTILITY <br />_LIGHT _�_ <br />EXISTING STORM <br />T <br />-DRAIN ,UTILITY -___.._____.--. --_-- <br />MAXIMUM <br />W\NOTE: UVi1TS h/Nl ARE FOR REFERENCE ONLY. SEE <br />MANHOLE <br />CIVIL DWGS. FOR DETAILS AND EXACT LOCATIONS. FINAL <br />MINIMUM <br />NORTH <br />LOCATIONS TO <br />BE REVIEWED BY LANDSCAPE ARCHITECT. <br />NORTHERLY <br />NOT TO SCALE <br />ON CENTER <br />ON CURVE <br />ORANGE COUNTY PUBLIC WORKS <br />PROPOSED, NEW <br />PLANTING AREA <br />PROPERTY LINE <br />POINT OF CONNECTION <br />POINT OF REVERSE CURVATURE <br />POLYVINYL CHLORIDE <br />RADIUS <br />REINFORCED CONCRETE PIPE <br />TOP RIM OF STRUCTURE <br />RIGHT <br />RIGHT OF WAY <br />SOUTH OR SLOPE <br />SOUTHERLY <br />SEWER CLEANOUT <br />STORM DRAIN <br />SQUARE FEET <br />SHEET <br />STATION <br />STANDARD <br />SANITARY SEWER MANHOLE <br />STANDARD PLANS FOR PUBLIC <br />WORKS CONSTRUCTION <br />STORM WATER POLLUTION <br />PREVENTION PLAN <br />TOP OF CURB <br />TOP OF GRATE <br />TOP OF FOOTING <br />TOP OF PIPE <br />TOP OF WALL <br />TYPICAL <br />UNLESS NOTED OTHERWISE <br />WEST <br />WESTERLY <br />WATER MAIN <br />PREPARED UNDER <br />THE SUPERVISION <br />OF: <br />SYMBOLS <br />55 <br />73 <br />vicinity MAP N <br />(NOT TO SCALE) <br />SHEET INDEX <br />SHEET NUMBER <br />DESCRIPTION <br />1 <br />TITLE SHEET <br />2 !DEMOLITION <br />PLAN <br />3 j <br />GRADING AND PAVING PLAN <br />4 <br />NOTES AND SCHEDULES <br />5 <br />MATERIALS PLAN <br />6 <br />LAYOUT PLAN <br />7 <br />ELEVATIONS AND SECTIONS <br />8 <br />CONSTRUCTION DETAILS <br />9 <br />i CONSTRUCTION DETAILS <br />10 <br />, SEWER PLAN AND PROFILE <br />Al <br />� STRUCTURAL NOTES AND DETAILS <br />112 <br />� TRAFFIC SIGNAL PLAN <br />13 <br />I SIGNAGE AND STRIPING PLAN <br />0 <br />N <br />G) <br />9 <br />Cn <br />& <br />Z_ <br />@ <br />AND <br />ANGLE <br />AT <br />Q:� <br />Li <br />CENTERLINE <br />0 <br />DIAMETER OR ROUND <br /># <br />POUND OR NUMBER <br />Li_ <br />APPROVEDBY <br />a b► L a •\,S�kbr, tar --- 3rl2oZ-4 <br />NABIL SABA, P.E. DATE <br />EXECUTIVE DIRECTOR <br />PUBLIC WORKS AGENCY <br />AW z 3 Z z <br />R DOLF OSAS, P.E. DATE <br />CITY ENGINEER <br />R.C.E. NO. 73963 <br />SENIOR CIVIL ENGINEER <br />KATHEREEN SHINKAI DESIGNED: AC DRAWN: ILL <br />REVIEWED FOR <br />PRINCIPAL CIVIL ENGINEER <br />RECOMMENDED FOR I4 <br />( nNI.gTRI IC;TIC)N <br />OWNER /DEVELOPER <br />SANTA ANA UNIFIED SCHOOL DISTRICT <br />JULIE A. MOLLOY <br />SENIOR FACILITIES PLANNER <br />OFFICE: (714) 480-5367 <br />MOBILE: (657) 336-0244 <br />JU LI E. M OLLOY®SAU SD. U S <br />NA <br />N <br />0 <br />0 <br />0 (_0 <br />0- N-) <br />me <br />0 <br />DATz <br />E TITLE SHEET <br />05/2 CH01 <br />CHECKED: KS SEGERSTROM AVENUE AT ROSEWOOD AVENUE w <br />PRINCIPAL CIVIL ENGINEER RCE NO.: 66219 <br />949-261-1001 Office <br />949-260-1190 Fax <br />LPADesignStudios.com <br />5301 California Avenue <br />Suite 100 <br />Irvine, California 92617 PROJECT ADDRESS: <br />ARCHITECTURE ENGINEERING INTERIORS 2802 S. FLOWER ST. <br />ANDSCAPE ARCHITECTURE PLANNING <br />100' W/O ROSEWOOD AVENUE TO 100' E/O ROSEWOOD AVENUE <br />PUBLIC WORKS AGENCY 01:� <br />CITY OF SANTA ANA SHEET 1 OF 13 n <br />