My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2025
>
01/21/2025
>
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 4:50:22 PM
Creation date
1/21/2025 3:12:07 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
18
Date
1/21/2025
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />1. IF TRENCH WALLS SLOUGH SO AS TO REMOVE FIRM SUPPORT TO ADJACENT PAVEMENT, SUCH PAVEMENT <br />SHALL BE REMOVED BACK TO WHERE UNDISTURBED IS AVAILABLE. THE REMOVAL OF PAVEMENT <br />UNDER SUCH CONDITIONS SHALL BE FOR A MINIMUM DISTANCE OF 10 FEET ALONG THE TRENCH, AND <br />THE WIDTH OF REMOVAL SHALL BE CONSTANT AND EQUAL TO THE GREATEST DIMENSION REQUIRED FOR <br />REMOVAL TO FIRM SUPPORT. <br />2. PAVEMENT REPLACEMENT SHALL BE DONE ACCORDING TO CITY OF SANTA ANA STANDARD PLAN NUMBERS <br />1150 SHEET 1. 2 AND 1151. <br />3. COMPACT THE SAND BEDDING USING THE JETTING METHODS PER THE "GREENBOOK" <br />4. INSTALL DETECTABLE UTILITY MARKING TAPE - (COLOR CODED PER DIG ALERT SUGGESTED MARKING <br />GUIDELINES.) <br />5. ALL TRENCHING AND CONSTRUCTION OPERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE <br />STATE'S DEPARTMENT OF INDUSTRIAL RELATIONS. <br />6. UTILITY PIPE SHALL BE INSTALLED IN THE CENTER OF THE TRENCH. <br />7. ALL TRENCH ZONE BACKFILL MUST CONFORM TO SECTION 200 OF THE "GREENBOOK" AND SHALL BE <br />PLACED ACCORDING TO SECTION 306-1.3. IN ADDITION, WHEN NATIVE BACKFILL MATERIAL IS <br />ALLOWED, THE CONTRACTOR SHALL TEST THE MATERIAL TO SHOW THAT THE MATERIAL IS SUITABLE <br />FOR BACKFILL. SUITABLE NATIVE BACKFILL MATERIAL MAY ONLY BE USED WITH PRIOR APPROVAL <br />FROM THE CITY ENGINEER. THE MATERIAL IS NOT SUITABLE IF SAND EQUIVALENT IS LESS THAN 30 <br />OR IF THE MOISTURE CONTENT EXEEDS THE OPTIMUM. <br />8. USE ]12 SACK SAND/CEMENT SLURRY BACKFILL FOR TRENCHES LESS THAN 10" WIDE. SLURRY IS <br />ALLOWED IN CITY OWNED UTILITIES WITH PRIOR APPROVAL BY THE CITY ENGINEER. <br />o CITY OF SANTA ANA <br />CITY ENGINEER PUBLIC WORKS AGENCY <br />DATE I REVISION STD. PLAN <br />2/14/00 REVISED STANDARD PLAN NUMBER UTILITY TRENCH DETAIL NUMBER <br />TRENCH MATERIALS 1150 <br />AND BACKFILL REQUIREMENTS SHEET50F5 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.