Laserfiche WebLink
CITY OF SANTA ANA <br /> SPECIFICATIONS <br /> PROJECT NO.: 25-6030 <br /> TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br /> AVENUE <br /> 14. Submit a sewer overflow emergency response plan. The plan will dictate backup <br /> pumping plans, spill containment procedures, spill recovery procedures and <br /> emergency call out phone numbers. <br /> Provision shall be made by the Contractor for the collection of sewage from cutoff lateral <br /> sewers. Lateral sewers shall be reconnected to the main before the termination of every <br /> working day. <br /> The text of Subsection 306-1.6 of the Standard Specifications is hereby deleted and <br /> replaced with the following: <br /> Pipe shall be measured along the longitudinal axis between the ends as laid and <br /> shall include the actual pipe in place. <br /> 6.10 POLYVINYL CHLORIDE(PVC) SEWER PIPE <br /> Installation and construction of PVC sewer main shall conform to all applicable provisions <br /> of the ASTM D2321-05 (or later) "Underground Installation of Thermoplastic Pipe for <br /> Sewers and Other Gravity Flow Applications," Standard Specifications and these Special <br /> Provisions and the construction plans. <br /> Where indicated on the plans,sanitary sewer pipe shall be Polyvinyl Chloride(PVC)sewer <br /> pipe with compression joints conforming to Subsection 207-8 of the Standard <br /> Specifications. <br /> Underground conduit construction shall conform to all applicable Subsections of Section <br /> 306 of the Standard Specifications, the Standard Plans and these Special Provisions. <br /> PVC sewer pipe shall be manufactured by JM Eagle or approved equivalent. <br /> PVC gravity sewer pipe and fittings shall conform to ASTM D3034 for diameters from 4" <br /> - 15",and ASTM F679 for 18" -24",with integral bell gasket joints. Rubber gaskets shall <br /> be factory installed and conform to ASTM F477. <br /> Pipe shall be made of PVC plastic having a cell classification of 12454B or 12364B as <br /> defined in ASTM D1784 and shall have SDR of 26 and minimum pipe stiffness of 115 psi <br /> according to ASTM Test D2412. <br /> Pipe shall be installed in compliance with ASTM D2321. Bedding material shall provide <br /> adequate and uniform support under the pipe. <br /> Pipe shall not be stored in direct sunlight. Pipe stored outdoors shall be protected from the <br /> natural elements by covering it with opaque material such as canvas. The covering shall <br /> be placed in such a way as to allow adequate air circulation between the cover and the pipe. <br /> Discolored pipe will not be allowed. <br /> 94 <br />