Laserfiche WebLink
CITY OF SANTA ANA <br /> SPECIFICATIONS <br /> PROJECT NO.: 25-6030 <br /> TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br /> AVENUE <br /> for pavement,curb and gutter. Longitudinal joints shall be aligned such that they will cross <br /> manholes and water valves at centerline if possible. Transverse construction joints within <br /> 11 shall cross all manholes and water valves. Provide a weakened plane joint around the <br /> perimeter of all utility vaults. <br /> 1.16 LANDSCAPING AND IRRIGATION REPAIR <br /> This section shall conform to Sections 212 and 308 of the Standard Specifications. <br /> All lawn and landscaped areas disturbed by the Contractor as part of or as a result of the <br /> work shall be prepared/brought to adjacent grade and restored to match existing <br /> landscaping. If there are any existing sprinkler heads and irrigation lines in the construction <br /> areas, whether on public or private property, they shall be replaced or relocated by the <br /> Contractor. <br /> 1.17 ROOT SHAVING <br /> Root shaving shall be done in accordance with City of Santa Ana Standard Plan No. 1124A <br /> at locations designated on Plans or as directed by the Engineer. Prior to shaving any tree <br /> root, the Contractor shall coordinate with the City's Tree Maintenance Supervisor. <br /> 1.18 ADJUSTMENT OF SURFACE UTILITIES TO GRADE <br /> General <br /> All AGENCY-owned utility frames and covers within the area to be paved or graded, <br /> shall be set to finished grade by Contractor after construction of new asphalt concrete <br /> pavement as shown on the plans,per these Special Provisions and the Standard <br /> Specifications in 301-1.6 "Adjustment of Manhole Frame and Cover Sets to Grade" and <br /> in conformance with the City's Standard Plans. In Portland cement concrete pavement <br /> and sidewalk areas, AGENCY-owned utility frames and covers shall be adjusted to grade <br /> prior to placement of concrete. <br /> All other utility frames and covers shall be set to finished grade by the respective utility <br /> company. Manholes and other structures in asphalt concrete pavement shall be set to <br /> finished grade in accordance with the provisions of subsection 302-5.8 of the Standard <br /> Specifications. <br /> Contractor shall tie out all utility locations prior to paving. <br /> Pull Boxes <br /> When lowering pull boxes to new grade, box frame and lid shall have a minimum 4" <br /> clearance from any cabling. If necessary, Contractor shall lower conduit by redirecting <br /> conduit or removing Subgrade in box area. Cost shall be included in the price bid for <br /> adjusting to grade, and no additional allowance shall be made therefore. <br /> 38 <br />