My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
JOHNSON CONTROL INC. 1 -2003
Clerk
>
Contracts / Agreements
>
J
>
JOHNSON CONTROL INC. 1 -2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2014 4:30:42 PM
Creation date
8/5/2003 3:20:15 PM
Metadata
Fields
Template:
Contracts
Company Name
Johnson Control Inc.
Contract #
A-2003-122
Agency
Finance & Management Services
Council Approval Date
6/16/2003
Expiration Date
7/31/2006
Insurance Exp Date
10/1/2008
Destruction Year
2011
Notes
Amended by A-2003-122-02
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H/2t%2003 FRI 12:04 FAX 562 799 9443 JCI OPERATIONS CYPRESS 0131013 <br />Schedule 213 <br />- METrASYS- <br />AHU, UNT, and DX Application Specific Controllers <br />On a Scheduled Basis <br />DX Application Speck Controller <br />Verify that DX is being controlled at the appropriate <br />values. <br />Change one set point value; verify smooth transition <br />and, stable control at the new set point. <br />Return set point to original value. <br />Repeat for each additional control loop, if any. <br />Verify that controlled valves and dampers will stroke <br />fully in both directions, seating tightly where <br />appropriate. <br />Verify the proper operation of critical control <br />processes and points associated with this unit. Make <br />adjustments if necessary. <br />UNITARY Equipment Application Specific <br />Controller <br />Verify that ASC is In control at the desired value(s). <br />Change one set point value; verify smooth transition <br />and stable control at the new set point. <br />Return set point to original value. <br />Repeat for each additional control loop, if any. <br />Additional Tasks and/or Special Instructions: <br />Form E9762 (Rev 10 /00) <br />Verify that controlled valves and dampers will stroke <br />fully in both directions, sealing tightly where <br />appropriate. <br />Verify the proper operation of critical control <br />processes and points associated with this unit. Make <br />adjustments if necessary. <br />AHU Application Speciific Controller <br />Verify that AHU is being controlled at the appropriate <br />values. <br />Change one set point value; verify smooth transition <br />and stable control at the new set point. <br />Return set point to original value. <br />Repeat for each additional control loop, .if any. <br />Verify that controlled valves and dampers will stroke <br />fully in both directions. seating tightly where <br />appropriate. <br />Verify the proper operation of critical control <br />processes and points associated with this unit. Make <br />adjustments if necessary. <br />As Required <br />Verify /calibrate other points associated with these <br />units where the need for possible "Corrective <br />Maintenance" is indicated. <br />
The URL can be used to link to this page
Your browser does not support the video tag.