Laserfiche WebLink
<br />1. <br /> <br />Living Room <br /> <br />1.1 Living Room Present <br /> <br />Note: If the unit is an efficiency apartment, consider the living room <br />present. <br />1.2 Electrictty <br /> <br />In order to qualify. the outlets must be present and properly installed <br />in the baseboard, wall or floor of the room. Do not count a single <br />duplex receptacle as two outlets, i.e., there must be two of these in <br />the room, or one of these plus a permanently installed ceiling or <br />wall light fixture. <br /> <br />Both the outlets and/or the light must be working. Usually, a room will <br />have sufficient lights or electrical appliances plugged into oullets to <br />determine workability. Be sure light fixture does not fail just because <br />the bulb is burned out. <br /> <br />Do not count any of the following items or fixtures as outlets/fixtures: <br />Table or floor lamps (these are not permanent light fixtures); ceiling <br />lamps plugged into socket; extension cords. <br /> <br />If the electric service to the unit has been temporarily turned off <br />check "Inconclusive." Contact owner or manager after inspection to <br />verify that electricity functions properly when service is turned on. <br />Record this infonmation on the checklist. <br /> <br />1.3 Electrical Hazards <br /> <br />Examples of what this means: broken wiring; noninsulated wiring; <br />frayed wiring; improper types of wiring, connections or insulation; <br />wires lying in or located near standing water or other unsafe places; <br />light fixture hanging from electric wiring wtlhout other finm support or <br />fixture; missing cover plates on switches or outlets; badly cracked <br />outlets; exposed fuse box connections; overloaded circuits evi- <br />denced by frequently "blown" fuses (ask the tenant). <br /> <br />Check ~lnconclusive" if you are uncertain about severity of the <br />problem and seek expert advice. <br /> <br />1. 4 Security <br /> <br />"Accessible to outsideN means: doors open to the outside or to a <br />common public hall; windows accessible from the outside (e.g. <br />basement and first floor); windows or doors leading onto a fire <br />escape, porch or other outside place that can be reached from the <br />ground. <br /> <br />"Lockable" means: the window or door has a properly working lock, <br />or is nailed shut, or the window is not designed to be opened. A storm <br />window lock that is working properly is acceptable. Windows that are <br />nailed shut are acceptable only if these windows are not needed for <br />ventilation or as an alternate exit in case of fire. <br /> <br />1.5 Window Condition <br /> <br />Rate the windows in the room (including windows in doors). <br /> <br />"Severe deteriorationN means that the window no longer has the <br />capacity to keep out the wind and the rain or is a cutting hazard. <br />Examples are: missing or broken-out panes; dangerously loose <br />cracked panes; windows that will not close; windows that, when <br />closed, do not form a reasonably tight seal. <br /> <br />If more than one window in the room is in this condition, give details <br />in the space provided on the right of the form. <br /> <br />If there is only "moderate deterioration" of the windows the item <br />should "Pass.- "Moderate deterioration" means windows which are <br />reasonably weafher-tight, but show evidence of some aging, abuse, <br />or lack of repair. Signs of deterioration are: minor crack in window <br />pane; splintered sill; Signs of some minor rotting in the window frame <br />orthe window itself; window panes loose because of missing window <br />pulty. Also for deleriorated and peeling paint see 1.9. If more than <br />one window is in this condition, give details in the space provided on <br />the right of the form. <br /> <br />Previous editions are obsolete <br /> <br />Page 2 of 20 <br /> <br />1.0 Celllng C.ondltlon <br /> <br />"Unsound or hazardous" means the presence of such serious de- <br />fects that either a potential exists for structural collapse or that large <br />cracks or holes allow significant drafts to enter the unit. The condition <br />includes: severe bulging or buckling; large holes; missing parts; <br />falling or in danger of falling loose surface materials (other than <br />paper or paint). <br /> <br />Pass ceilings that are basically sound but have some nonhazardous <br />defects, including: small holes or cracks; missing or broken ceiling <br />tiles; water stains; soiled surfaces; unpainted surfaces; peeling paint <br />(for peeling paint see item 1.9). <br />1.7 Wall Condition <br /> <br />"Unsound or hazardous" includes: serious defects such that the <br />structural safety of the building is threatened, such as severe <br />buckling, bulging or leaning; damaged or loose structural members; <br />large holes; air infiltration. <br /> <br />Pass walls that are basically sound but have some nonhazardous <br />defects, including: small or shallow holes; cracks; loose or missing <br />parts; unpainted surfaces; peeling paint (for paeling paint see item 1.9). <br /> <br />1.8 Floor Condition <br /> <br />"Unsound or hazardous" means the presence of such serious de- <br />fects that a potential exists for structural collapse or other threats to <br />safety (e.g., tripping) or large cracks or hoies allow substantial drafts <br />from below the floor. The condition includes: severe buckling or <br />major movements under walking stress; damaged or missing parts. <br /> <br />Pass floors that are basically sound but have some nonhazardous <br />defects, Including: heavily worn or damaged floor surface (for ex- <br />ample, scratches or gouges in surface, missing portions of tile or <br />linoleum, previous water damage). If there is a floor covering, also <br />note the condition, especially if badly worn or soiled. llthere is a floor <br />covering, including paint or sealant, also note the conditions, spe- <br />cially if badly worn, soiled or peeling (for peeling paint, see 1.9). <br /> <br />1.9 Lead-Based Paint <br /> <br />Housina Choice Voucher Units If the unit was built January 1, <br />1978, or after, no child under age six will occupy or currently <br />occupies it, is a O-BR, eiderly or handicapped unit with no children <br />under age six on the lease or expected, has been certified lead.. <br />based paint free by a certified lead-based paint inspector (no <br />lead-based paint present or no lead-based paint present after <br />removal of lead-based paint.), check NA and do not inspect <br />painted surfaces. <br /> <br />This requirement applies to all painted surfaces (building compo- <br />nents) within the unit. (Do not include tenant belongings). <br />Surfaces to receive a visual assessment for deteriorated paint <br />include walls, floors, ceilings, buiit in cabinets (sink bases), <br />baseboards, doors, door frames, windows systems including <br />mullions, sills, or frames and any other painted building compo- <br />nent within the unit. Deteriorated paint includes any painted <br />surface that is peeling, chipping, chaiking, cracking, damaged or <br />otherwise separated from the substrate. <br /> <br />All deteriorated paint surfaces more than 2 sq. ft, In anyone <br />interior room or space, or more than 10% of the total surface <br />area of an interior type of component with a small surface <br />area (i.e., window sills, baseboards, and trim) must be stabi- <br />lized (corrected) in accordance with all safe work practice <br />requirements and clearance is required. If the deteriorated <br />painted surface is less than 2 sq. ft. or less than 10% of the <br />component, only stabilization is required. Clearance testing <br />is not required. Stabilization means removal of deteriorated <br />paint, repair of the substrate, and application of a new protective <br />coating or paint. Lead-Based Paint Owner Certification is <br />required follOWing stabilization activities, except for de minimis <br />lAVAl rAD;:tir~ <br /> <br />form HUD-52580-A (9//2000) <br />ref Handbook 7420.8 <br />