My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 22 - Agreements for On-Call Programmable Logic Controller Programming and Consulting Services
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2025
>
09/16/2025
>
Item 22 - Agreements for On-Call Programmable Logic Controller Programming and Consulting Services
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 10:46:16 AM
Creation date
9/10/2025 8:35:22 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
22
Date
9/16/2025
Destruction Year
P
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANEL CONSTRUCTION COMMENTS AND SPECIAL INSTRUCTIONS <br />DEVICE WIRING: <br />UNLESS OTHERWISE INDICATED, ALL 1/0 TERMINAL BLOCKS ARE TO BE WIRED WHERE 1/0 <br />DEVICE WIRING TERMINATES ON THE LEFT AND PLC MODULE WIRING TERMINATES ON THE <br />RIGHT. <br />THIS REQUIREMENT APPLIES TO: <br />TB-1 <br />TB-2 <br />TB-3 <br />TB-4 <br />INPUT LSA (TVSS) IS TO BE MOUNTED AND WIRED SUCH THAT FIELD TERMINATIONS ARE <br />ON THE RIGHT AND PANEL WIRING IS ON THE LEFT. <br />GROUND BUS: <br />MOUNT GROUND BUS DIRECTLY TO BACK PANEL. BOND GROUND BUS STRIPS TOGETHER <br />WITH SINGLE CONDUCTOR AT ONE END ONLY, #12AWG (GREEN) WIRE. <br />DO NOT GROUND CONTROL COMPONENTS TO BACK PANEL. RUN SINGLE CONDUCTORS <br />DIRECTLY TO GROUND BUS AS SHOWN ON SHEET 15 OF DRAWING SET. <br />CONNECT GROUND STUD ON ENCLOSURE DOORS DIRECTLY TO ENCLOSURE GROUNDING <br />STUD(S) USING SINGLE CONDUCTOR OF #14AWG (GREEN) WIRE. <br />TERMINAL MARKING: <br />PANEL BUILDER TO PROVIDE PHOENIX ZACK MARKER STRIPS FOR TERMINALS USING <br />MECHANICAL MARKING SYSTEM FOR TERMINAL NUMBERS. (NO HAND-WRITTEN TERMINAL <br />NUMBERS ALLOWED) <br />ENCLOSURE ASSEMBLY <br />ENCLOSURE DOOR STOP TO BE INSTALLED WITH WELDED STUDS ON THE DOOR AND <br />BOLTS WITH SEALING WASHERS ON THE ENCLOSURE. <br />DEVICE LABELS: <br />UNLESS OTHERWISE INDICATED, ALL DEVICE LABELS ARE TO <br />BE MECHANICALLY FASTENED. <br />TERMINAL STRIP IDENTIFICATION LABELS TO BE MOUNTED TO THE TOP OF <br />EACH TERMINAL STRIP USING DIN RAIL MOUNTED LABEL HOLDERS. <br />THIS REQUIREMENT APPLIES TO: <br />TB-1 TB -RELAYS <br />TB-2 <br />TB-3 <br />TB-4 <br />WIRE MARKING: <br />LABEL CURRENT -CARRYING WIRE/CABLE WITH COMPUTER <br />PRINTED HEAT SHRINK MARKING SLEEVES. <br />ATTACH WIRE DUCT TO PANEL WITH METAL FASTENERS. <br />USE DUAL WIRE CABLE ENDS WHENEVER 2 WIRES ARE <br />INSERTED INTO A SINGLE TERMINATION POINT. <br />WIRE COLOR AND SIZES <br />UNLESS OTHERWISE SPECIFIED IN THE DRAWING SET, ALL WIRES TO BE SIZED AND COLORED <br />AS FOLLOWS: <br />120VAC = RED, 14 AWG, MTW <br />120VAC NEUTRAL = WHITE, 14 AWG, MTW <br />GROUND = GREEN, 14 AWG, MTW <br />120VAC NOT DISCONNECTED BY PANELS MAIN CIRCUIT BREAKER = ORANGE, 14 AWG, MTW <br />24VDC = BLUE, 16 AWG, MTW <br />OVDC = WHITE/BLUE, 16 AWG, MTW <br />DISCRETE INPUTS = BLUE, 16 AWG, MTW <br />DISCRETE OUTPUTS = YELLOW, 16 AWG, MTW <br />ANALOG INPUTS AND OUTPUTS = PURPLE, 16 AWG, MTW <br />Ef`ITERPRISE <br />THIS DRAWING IS THE PROPERTY OF ENTERPRISE AUTOMATION <br />AND IS NOT TO BE USED IN WHOLE OR PART FOR ANY PROJECT <br />OTHER THAN THE ONE IDENTIFIED HEREIN WITHOUT THE WRITTEN <br />AUTHORIZATION OF ENTERPRISE AUTOMATION. THIS DRAWING <br />Ho s <br />W <br />ome <br />'ll. <br />CUSTOMER INFO: <br />CITY OF SANTA ANA <br />WELL 40 <br />WELL 40 RTU <br />CONSTRUCTION COMMENTS <br />'"V-'"uM°`" <br />EA18CSA018 <br />0.1 <br />O5/14/18 <br />SUBMITTAL <br />0.2 <br />0623118 <br />FOR CONSTRUCTION <br />AUTOMATION <br />210 GODDARD <br />IRVINE, CA 92618 <br />PHONE: (949) 769-6000 FAX: (949) 769-6005 <br />SHALL NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT <br />THE EXPRESSED WRITTEN CONSENTOF ENTERPRISE <br />AUTOMATION. <br />0.3 <br />10/18/18 <br />RELAY UPDATES <br />1301 N. MABURY STREET <br />SANTA ANA, CA 92701 <br />onTe. �m <br />unnfT eHcixSM 'EC <br />NO SCALE <br />xuxaoa <br />05 <br />n ewwe: <br />EAI8CSA018 WELL00 RN BHT OS.OWG <br />