Laserfiche WebLink
TVSS <br />L — AC <br />CUSTOMER INPUT TRANSIENT <br />SUPPLY #1 VOLTAGE SURGE <br />120VAC SUPRESSOR <br />1-PH/6OHz N — NEU LINE LOAD <br />W/FACILITY <br />GROUND <br />SEE NOTE 1 L <br />GND <br />SEE SELECTOR SEE SELECTOR <br />CB135A) SWITCH SETTINGS PART TB -AC -OF <br />H CB13) SWITCH SETTINGS <br />1301 1311 1302 1302 1312 <br />� 0 <br />AUX AUX <br />(SHT 15) (SHT 15) <br />WIRE COLOR: ORANGE CB1303 (3A) <br />WIRE SIZE: #14 AWG \1 <br />[INTERNAL FUSE MDA 15A] WIRE TYPE: MTW 1303 1303 ^ 1313 <br />�oUD <br />GND <br />0 <br />G WIRE COLOR: GREEN SHT 13 GND �000 <br />WIRE SIZE: #12 AWG <br />WIRE TYPE MTW <br />AIR COND <br />SHT 13 <br />DC POWER SUPPLY <br />SHT 15 <br />Al BASE 1 <br />SHT25 <br />TEMP SENSOR <br />(SHT 18) <br />LAPTOP POWER <br />® _GND FIELD DEVICES AND <br />CONDUIT <br />SEE AIR <br />CB1304 (3A) AIR CONDITIONER //_ CONDITIONER SETTINGS <br />GND GND Al BASE 2 1304 1304 1314 L <br />SHT 26 <br />I <br />SHT 13 GND PE <br />GND GND AO BASE 1 <br />SHT 27 <br />CB1305 (3A) <br />GND GND AO BASE 2 t133O51305 � 1315 <br />SHT 27 1 <br />1316 <br />GND I LAPTOP POWER 5 , <br />SHT 13 HUMIDISTAT <br />SEE HUMIDISTAT <br />GND ENCLOSURE LIGHT FIXTURE SETTINGS <br />SHT16 <br />GND 250W RADIANT HEATER <br />SHT 13 <br />67 <br />250W <br />RADIANT <br />HEATER <br />SHT 13 / GND <br />PART OF <br />TB-AC-N <br />1352 1352 <br />I I <br />I I <br />1353 �1353 <br />I I <br />I I <br />I I <br />1354 1354 <br />I I <br />I I <br />1355 1355 <br />1356 1356 <br />X54 <br />® <br />®®®® ®® <br />CONTACT 4.XX IN ALARM MODE 0 <br />1 <br />B <br />CONTACT 1.XX IN AUXILARY MODE RED <br />70 90J50K�90 <br />2 <br />�1 <br />AIR CONDITIONER SETTINGSSHT29 <br />PLC RACK POWER SUPPLY GND <br />CB AUX CONTACT MODE <br />13 <br />L32 <br />SELECTOR ROTARY SWITCH <br />°FMAGELISOIT <br />MIDIS <br />GND <br />SHT29 <br />Ef`ITERPRISE <br />THIS DRAWING IS THE PROPERTY OF ENTERPRISE AUTOMATION <br />x��' <br />� E <br />REVOON s �r <br />CUSTOMER INFO: <br />E <br />WELL 4O RTU <br />� TNxxaEaji6. <br />AND IS NOT TO BE USED IN WHOLE OR PART FOR ANY PROJECT <br />(1( SUPPLY NOT TO EXCEED I5 AMPS SERVICE <br />0.1 <br />O5/14/18 <br />SUBMITTAL <br />CITY OF SANTA ANA <br />OTHER THAN THE ONE IDENTIFIED HEREIN WITHOUT THE WRITTEN <br />0.2 <br />0623118 <br />FOR CONSTRUCTION <br />WELL 40 <br />AC POWER DISTRIBUTION <br />EA18CSA018 <br />AUTOMATION <br />RAW <br />AUTHORIZATION OF ENTERPRISE AUTOMATION. THIS DING <br />SHALL NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT <br />0.3 <br />10/18/18 <br />RELAY UPDATES <br />—E. eHc <br />unnfT ixSM ��JC <br />210 GODDARD <br />THE EXPRESSED WRITTEN CONSENTOF ENTERPRISE <br />1301 N. MABURY STREET <br />NO SCALE <br />xuxEEa <br />IRVINE, CA 92618 <br />PHONE: (949) 769-6000 FAX: (949)769-6005 <br />AUTOMATION. <br />SANTA ANA, CA 92701 <br />n EwwE: <br />EA1=18MU_QMSHT 13.1— <br />1 3 <br />