My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
TAIT ENVIRONMENTAL SERVICES
Clerk
>
Contracts / Agreements
>
T
>
TAIT ENVIRONMENTAL SERVICES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2025 3:11:40 PM
Creation date
10/3/2025 3:11:05 PM
Metadata
Fields
Template:
Contracts
Company Name
TAIT ENVIRONMENTAL SERVICES
Contract #
N-2025-252
Agency
Public Works
Expiration Date
6/30/2026
Insurance Exp Date
9/1/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT A <br /> Scope of Work <br /> Provide Designated Underground Storage Tank(UST) Operator Services as well as testing, <br /> maintenance and repair services for its UST fuel sites, listed below: <br /> • Corporate Yard (5 UST)-W-215 S. Center Street, Santa Ana, CA 92703 <br /> • Police Department (2 UST)—60 Civic Center Plaza, Santa Ana, CA 92701 <br /> • Additional sites may be added during the term of the contract. <br /> Must be a certified California UST System Operator. Services will include 30-Day inspections, <br /> annual &triennial testing,conducting City staff training, and scheduled or emergency <br /> maintenance and repairs. Assist the City with maintaining compliance with UST regulations and <br /> shall adhere to all applicable Federal, State, and Local regulations pertaining to the operations, <br /> maintenance, and reporting for UST systems. Shall notify the City within (1)business day of <br /> discovering any suspected issue or activity that could potentially cause non-compliance with any <br /> applicable regulation(s). <br /> Description of Project Responsibilities <br /> The City requires inspection services and maintenance of fuel sites that includes furnishing and <br /> delivering parts, supplies, and accessories for gasoline, diesel, and waste oil USTs. Additional <br /> miscellaneous items such as pumps, plumbing, tanks, nozzles and monitoring systems may also <br /> be requested. <br /> Maintain an adequate supply of replacement parts available on the service trucks. The supplies <br /> shall include, but not limited to, various Veeder-Root sensors (at least one of each type), Veeder- <br /> Rood probe cables, spill bucket train valves (at least one of each type),mechanical line leak <br /> detector and hanging hardware for a typical Gasoline and Diesel dispenser. <br /> Shall be licensed and/or certified to perform all inspections,testing, repairs, and alarm <br /> responses in compliance with all City, State and Federal regulations and in accordance to <br /> Departmental needs. Shall provide proof of certifications at the City's request.Fixed quotes may <br /> be required for projects and/or repairs. Shall notify City designee for any work that will exceed <br /> $1,000. <br /> Provide the City with their list of petroleum equipment supply vendors. Written confirmation <br /> from the parts vendor shall be provide to the City if is unable to obtain the parts within 48 hours. <br /> Failure to provide written confirmation could result in liquidated damages. <br /> Upon completion of any testing, shall submit an electronic copy of the test results and printouts <br /> to the City designee and the proper regulatory Agency. Shall include the City designee on any <br /> correspondence with regulatory Agencies and shall notify the City immediately of any failed test <br /> results. <br /> Responsible for disposing all waste generated during testing events. In the event of a waste or <br /> material spill that may pose adverse effects to the environment, shall notify the City immediately <br /> and shall promptly begin spill cleanup and abatement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.