Ordinance No. NS-XXX <br />Page 13 of 26 <br />1. When predicted sustained winds exceed 8 MPH and relative humidity is less than 25%, <br />or a red flag condition has been declared. <br />2. When an official sign was caused to be posted by the fire code official, or a public <br />announcement is made. <br />No outdoor fires using any fuel type are permitted when predicted sustained winds exceed 20 MPH <br />or when such fires present a hazard as determined by the fire code official. <br /> <br />Section 305.7 Disposal of rubbish is hereby added as follows: <br />305.7 Disposal of rubbish. Rubbish, trash or combustible waste material shall be burned only <br />within an approved incinerator and in accordance with Section 307.2.1. <br /> <br />Section 307 Open Burning, Recreational Fires And Portable Outdoor Fireplaces is hereby revised <br />as follows: <br /> <br />Section 307 Open Burning, Recreational Fires, Fire Pits, Fire Rings, And Portable Outdoor <br />Fireplaces <br /> <br />Sections 307.6 Outdoor fireplaces, fire pits, fire rings, or similar devices used at Group R <br />occupancies is hereby added as follows: <br />307.6 Outdoor fireplaces, fire pits, fire rings, or similar devices used at Group R <br />occupancies. Outdoor fireplaces, fire pits, fire rings, or similar exterior devices used at Group R <br />occupancies shall comply with this section. <br />Exception: Barbeques, grills, and other portable devices intended solely for cooking. <br /> <br />Section 307.6.1 Gas-fueled devices is hereby added as follows: <br />307.6.1 Gas-fueled devices. Outdoor fireplaces, fire pits and similar devices fueled by natural <br />gas or liquefied-petroleum gas are allowed when approved by the Building Department and the <br />device is designed to only burn a gas flame and not wood or other solid fuel. At R-3 occupancies, <br />combustible construction and vegetation shall not be located within three feet of an atmospheric <br />column that extends vertically from the perimeter of the device. At other R occupancies, the <br />minimum distance shall be ten feet. Where a permanent Building Department approved hood and <br />vent is installed, combustible construction may encroach upon this column between the bottom of <br />the hood and the vent opening. Where chimneys or vents are installed, they shall have a spark <br />arrester as defined in Section 202. <br /> <br />Section 307.6.2 Devices using wood or fuels other than natural gas or liquefied-petroleum gas is <br />hereby added as follows: <br />307.6.2 Devices using wood or fuels other than natural gas or liquefied-petroleum gas. <br />Permanent outdoor fireplaces burning wood or other solid fuel shall be constructed in accordance <br />with the California Building Code with clearance from combustible construction and building <br />openings as required therein. Fires in a fireplace shall be contained within a firebox with an <br />attached chimney. The opening in the face of the firebox shall have an installed and maintained <br />method of arresting sparks. <br />The burning of wood or other solid fuel in a device is not allowed within 25 feet of combustible <br />structures unless within an approved permanent fireplace. Conditions which could cause a fire to