EXHIBIT E <br /> NOISE ORDINANCE: <br /> A general awareness of all OC Fair& Event Center sound systems is important to understand the critical task of maintaining sound <br /> levels within a specific window for all areas in order to minimize the overall impact of sound from the OC Fair on surrounding <br /> neighborhoods. <br /> OC Fair sound systems will have strict sound control measures in place. <br /> ALL dB references are measured as FLAT response, NOT`A'weighted. This applies to all dB levels referenced herein. <br /> The OC Fair has a noise injunction specifically applied to the Pacific Amphitheatre. However,this applies to all events. <br /> The injunction states that at a distant house (547 Serra Way) the [eve[ must not exceed 55 dB. The house is approximately 2,000 <br /> feet from the Grandstand Arena, The injunction applies to all sound emanating from the OC Fair, DURING Fair time. <br /> For all year round events taking place outside of fair time, there is a 5 dB reduction in maximum levels. In other words, the 55 dB <br /> maximum is reduced to a 50 dB maximum. <br /> There is a strict 10:00 p.m. curfew in effect unless an extension of curfew is approved in writing by the CEO or COO of the 32"d <br /> District Agricultural Association (District) prior to the event. <br /> GENERAL SOUND LEVEL GUIDELINES,APPLIED TO ALL AREAS: <br /> NOTE: outside of fair,all references to 55 db are lowered to 50 dB. <br /> 1) Maximum, broadband (20 Hz to 15 KHz) noise level, measured at FOH, will not exceed peaks of 92 dB under any circumstances. <br /> 2) Behind the stage, measured at noise level will not exceed peaks of 70 dB under any circumstances. This includes direct FOH <br /> system energy, stage monitors, backline equipment and any reflected energy from the surrounding buildings. <br /> 3) Note that the objective is to keep SPL at or below 55 dB in ALL areas where houses are located. <br /> 4)Any combination of 1or 2 above resulting in noise levels exceeding 55 dB in surrounding neighborhoods must result in a lowering <br /> of level until the level in the neighborhood is within compliance. <br /> IN SUMMARY: <br /> NOTE: outside of fair,all references to 55 db are lowered to 50 dB. <br /> 1) No more than 55 dB in any area where a home is located. <br /> 2) No more than 70 dB behind stages, <br /> 3) No more than 92 dB at FOH. <br /> 4) If any combination of the above results in greater than 55 dB in any area where housing is located, levels will be immediately <br /> decreased until compliance is met. <br /> Measurements will be taken during each event to insure that the level is at or below an average of 92 dB at FOH, 70 dl3 at the rear of <br /> the stage. <br /> Every effort will be taken by the Contractor to insure that the noise ordinance is strictly adhered to. <br /> 1) In all cases, apply reasonable care to: <br /> a)Not interfere with surrounding vendors activities. <br /> b)Maintain a level reasonably consistent with the program material and audience size to be covered, <br /> c)At no time will the audio level exceed 90 d6 50 feet from the audio system. <br /> d)If speakers are in close proximity to audience members, sound level 10 feet from speakers will not exceed 85 d13. <br /> e)The Noise Injunction is to be respected and adhered to at all times. <br /> 2) Contractor is specifically responsible for insuring compliance as indicated herein. <br /> 3) Contractor will respond to requests from District personnel to reduce levels as required. <br />