My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FULL PACKET_2013-11-04
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2013
>
11/04/2013
>
FULL PACKET_2013-11-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2013 9:15:42 AM
Creation date
11/4/2013 8:39:57 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
11/4/2013
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
540
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(d) Section 4.1.3.3 is hereby added as follows: <br />(e) Section 4.1.3.4 is hereby added as follows: <br />4.1.3.4 A special sprinkler wrench shall be provided and kept in the cabinet to be <br />used in the removal and installation of sprinklers. One sprinkler wrench shall be <br />provided for each type of sprinkler installed. <br />(f) Section 7.1.2 is hereby revised as follows: <br />7.1.2 The system piping shall not have a separate control valve unless <br />supervised by a central station proprietary , or remote station alarm service. <br />(g) Section 7.6 is hereby deleted in its entirety and replaced as follows: <br />7.6 Alarms. Exterior alarm indicating device shall be listed for outside service <br />and audible from the street from which the house is addressed. Exterior audible <br />devices shall be placed on the front or side of the structure and the location is <br />subject to final approval by the fire code official. Additional interior alarm devices <br />shall be required to provide 55 dBA or 15 dBA above ambient whichever is <br />greater. Sound levels in all sleeping areas with all intervening doors closed shall <br />be a minimum of 15 dBA above the average ambient sound level but not less <br />than 75 dBA, whichever is greater. Audible devices shall be powered from an <br />uninterruptible circuit (except for over - current protection) serving normally <br />operated appliances in the residence. <br />Exception: <br />2. <br />When an approved water flow monitoring system is installed interior <br />sound an alarm upon waterflow switch activation. <br />SECTION 21: That section 8 -156 of the Santa Ana Municipal Code is hereby amended <br />such that it reads as follows: <br />Sec. 8- 156. Rese:ved. Installation of Standpipe and Hose Systems. <br />NFPA 14, 2013 Edition, Installation of Standpipe and Hose Systems is herebv <br />amended as follows: <br />Section 7.3.1.1 is hereby is deleted in its entirety and replaced as follows: <br />Ordinance No. NS -XXXX <br />75A -34 Page 20 of 84 <br />
The URL can be used to link to this page
Your browser does not support the video tag.