My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-2851
Clerk
>
Ordinances
>
2011 - 2020 (NS-2813 - NS-3000)
>
2013 (NS-2841 - NS-2856)
>
NS-2851
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2013 2:20:31 PM
Creation date
11/26/2013 1:52:41 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-2851
Date
11/18/2013
Destruction Year
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
903.2 Where required. Approved automatic sprinkler systems in buildings <br />and structures shall be provided when one of the following conditions <br />exists: <br />1. New buildings: Notwithstanding any applicable provisions <br />of Sections 903.2.1 through 903.2.12, an automatic fire - <br />extinguishing system shall also be installed in all occupancies <br />when the total building area exceeds 5,000 square feet (465 m2) <br />as defined in the CBC, regardless of fire areas or allowable area, <br />or more than two stories in height. <br />2. Existing Buildings: Notwithstanding any applicable <br />provisions of this code, an automatic sprinkler system shall be <br />provided in an existing building when an addition occurs and <br />when one of the following conditions exists: <br />a. When an addition is 33% or more of the existing building <br />area, and the resulting building area exceeds 5000 square <br />feet (465 m2) as defined in Section 202; or <br />b. When an addition exceeds 2000 square feet (186 m2) and <br />the resulting building area exceeds 5000 square feet (465 <br />m 2 ) as defined in Section 202. <br />c. An additional story is added above the second floor <br />regardless of fire areas or allowable area. <br />Exception: Group R -3 occupancies. Group R -3 occupancies shall <br />comply with Section 903.2.8. <br />(b) Section 903.2.8 Group R is hereby revised as follows: <br />903.2.8 Group R. An automatic sprinkler system installed in accordance <br />with Section 902.1 shall be provided throughout all buildings with a Group <br />R fire area as follows: <br />1. New Buildings: An automatic sprinkler system shall be <br />installed throughout all new buildings. <br />(c) Section 903.4 Sprinkler system supervision and alarms is hereby <br />revised to read as follows: <br />1. Automatic sprinkler systems protecting one- and two- family dwellings. <br />2. Limited area systems serving fewer than 20 sprinklers. <br />3. Jockey pump control valves that are sealed or locked in the open <br />position. <br />Ordinance No. NS -2851 <br />Page 8 of 67 <br />
The URL can be used to link to this page
Your browser does not support the video tag.