Laserfiche WebLink
City of Santa Ana <br />Server Upgrade Proposal <br />May 8, 2013 <br />Page 2 <br />WORK INCLUDED <br />1. Two (2) Dell PowerEdge servers (in accordance with City provided specification) with Red <br />Hat Linux OS and DYNAC® ES SCADA software. <br />2. Rebuilding of all existing City databases and graphics on new servers. <br />3. Freight and delivery of provided equipment to the City's facility. <br />4. Up to one (1) week of on -site installation and testing of communications of upgraded <br />SCADA system to all existing City remote PLCs. (City to directly test all control functions <br />under operational conditions). <br />5. As -built drawing(s) of server rack configuration. <br />6. Manufacturer's standard documentation for new equipment. <br />7. One (1) year DYNAC® software warranty. (Equipment manufacturers' warranties will be <br />passed through to the City). <br />WORK NOT INCLUDED <br />The following listing of "work not included" is intended as further clarification regarding <br />Transdyn's proposal. <br />1. Providing any new PLCs, instrumentation or control panel enclosure equipment <br />2. Providing any new workstation PC equipment. <br />3. Providing any new server equipment racks or KVM switches. <br />4. Performing any services in the capacity of a licensed Professional Engineer in the State of <br />California unless specifically stated otherwise in the Work Included section. <br />5. Installation of any equipment unless stated otherwise in the Work Included section. <br />6. Providing any control panels not specifically listed above in the Work Included section or <br />providing panels specified as provided with packaged systems or specified under other <br />specification sections. <br />7. Furnishing or installing any field wiring, cables, or making terminations unless specifically <br />stated otherwise in the Work Included section. <br />8. Furnishing or installing any field conduit, cable trays, junction boxes, connectors or other <br />electrical installation appurtenances. <br />9. Furnishing or installing any housekeeping pads, mounting brackets or any supports not <br />customarily furnished by the original equipment manufacturer. <br />10. Providing any submittal data, drawings, manuals, reports or record documentation other <br />than the deliverables listed above in the Work Included section. <br />11. Providing any commissioning, startup and operational support or any other services for non - <br />furnished hardware, software or systems. <br />TRANSDYN, INC. • 4256 Hacienda Drive, Suite 100 • Pleasanton, CA 94588 <br />Tel: (925) 225-1600 • Pax: (925) 225-16'10 • wwwaranscly..cont <br />