My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
19E - SANTA ANA GRADE SEPARATION PROJECT_Exhibit 2 in Color
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2014
>
12/02/2014
>
19E - SANTA ANA GRADE SEPARATION PROJECT_Exhibit 2 in Color
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2014 4:13:58 PM
Creation date
12/3/2014 4:08:00 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
19E
Date
12/2/2014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Santa. Ana Boulevard Grade Separation <br />September 13, 2011 <br />Page 4 <br />Preliminary Retaining Wall Recommendations <br />Earth retaining structures are proposed for the Santa Ana Boulevard Grade Separation Project. <br />The retaining walls consist of Caltrans Standard Type 1 cantilevered retaining wall and Type SW <br />cantilevered retaining wall. <br />Lateral Earth Pressure: A static active lateral earth pressure of 36 psf per foot of depth is <br />recommended for a free draining, level and compacted backfill. Materials placed behind the <br />retaining wall should be Caltrans Structure Backfill. <br />If applicable, a uniform lateral pressure due to vehicular traffic loading, equivalent to a vertical <br />pressure produced by at least 2 feet of earth with a soil unit weight of 120 lb/fe, should be added <br />to the above lateral earth pressure. Using an active earth pressure of 0.3, the recommended <br />uniform lateral earth pressure due to traffic loading is 72 psf. <br />In addition to the above loadings, the two railroad tracks will induce additional surcharge on the <br />adjacent retaining wall located within the horizontal zone of influence. The uniform lateral earth <br />pressure due to railroad surcharge and the extent of horizontal zone of influence will be <br />determined during the PS&E phase using additional project information. <br />Lateral Resistance: Resistance to lateral loads may be developed by a combination of friction <br />acting at the base of the wall and passive earth pressure. A maximum passive equivalent fluid <br />pressure of 370 psf per foot and a frictional coefficient of 0.4 between the soil -concrete interface <br />can be used for preliminary design. We recommend 100% of the base friction for static loading. <br />For seismic loading, we recommend combining 100% of the passive resistance and 100% of the <br />base friction. <br />Shallow Foundation Design: Using a maximum overexcavation depth (below the footing bottom) <br />of three feet or less and some assumed footing bottom elevations, our calculations show that the <br />allowable bearing capacity is about 3 kips per square foot (ksf). Using the 2006 Caltrans <br />Standard Plan Sheets for Type -I walls, this implies that Type -I wall with a height of 12 feet or <br />less can be supported on a spread footing. For Type -1 wall heights greater than 12 feet and Type - <br />SW walls with bearing pressures greater than 3 ksf, we recommend using deep foundations. <br />Foundation type for the retaining walls will be re -visited when site specific soil boring data <br />become available during the PS&E phase. <br />The horizontal limits of the overexcavation should begin one foot from each edge of the footing <br />bottom and extending downward at a 45 -degree imaginary plane until the plane intersects the <br />overexcavation depth. Prior to backfilling, the excavation bottom should be proof -rolled and <br />after that the excavation bottom should be inspected by a qualified geotechnical engineer or <br />technician to confirm the presence of an unyielding and competent surface. Onsite soils may or <br />may not be suitable for use as backfill; if not, Caltrans Structure Backfill is recommended. <br />Backfill should be compacted to a minimum relative compaction of 95% of maximum density as <br />determined by Caltrans Test Method 216. <br />Minimum footing embedment and offset (from a slope face) for retaining wall should be based <br />on Section 4.4.5.1 of Caltrans Bridge Design Specifications (Caltrans, 2003). <br />Earth Mechanics Inc. <br />Geotechnical & Earthquake Engineering <br />
The URL can be used to link to this page
Your browser does not support the video tag.