Laserfiche WebLink
Preliminary Design Report Addendum No.2 <br />Channel Hydraulic Analysis Results <br />Tables A -2 -1 and A -2 -2 show the HEC -RAS results for every cross section for the existing and proposed <br />conditions, respectively. Figure A -2 -2 shows the existing and proposed conditions profile plots. Figure A- <br />2-3 shows the existing and proposed conditions cross - section flow depths. <br />For the proposed conditions, the largest flow that can pass through the channel in which the depth <br />everywhere in the channel is below 15 feet (which includes 1 foot freeboard) is the 1.2 -year storm. This is <br />equivalent to a flow of 2,483 cfs in the upstream part of the channel and 2,633 cfs in the downstream part <br />of the channel, at the in- channel flow diversion structure. <br />3.7.2 Diversion Facility Hydraulics <br />This section summarizes the results of the hydraulic analysis for the diversion facility, which includes the <br />intake, coarse - screen, fine- screen, sedimentation chamber, storage tank and outlet discharge structure, <br />pump station and associated conveyance force mains. For conveyance pipeline by gravity and pressurized <br />force mains, the C factor (Hazen - Williams coefficient) of 120 was used for all pipe sizes in this hydraulic <br />study, which corresponds to a moderate pipe operational condition. The specified inside diameter <br />dimensions, pipe length and associated valves, bends and other appurtenances were based on preliminary <br />levels, and verification will be needed in further design stages. <br />The proposed facility's hydraulic profiles for 0.4 cfs dry- weather and 100 cfs maximum design flow <br />conditions are depicted in Appendix A -1 sheet PD -2. <br />Detailed diversion facility hydraulic analyses results can be found in Appendix A- 3 <br />Intake Pipe to Pre Coarse - screen Chamber <br />Of particular importance is the need to provide redundancy for each component within the intake <br />structure for the diversion facility. Various events could potentially reduce or eliminate the water supply <br />normally available via a single intake (e.g., periodic maintenance on the intake structure). To adequately <br />ensure a robust intake system, two 48" diameter RCP and channel side inlets are proposed for the <br />preliminary design of the intake structure. <br />The proposed intake pipe from the proposed intake to the proposed treatment facility is shown in <br />Appendix A -1 PD -1. The intake consists of two parallel slide gate structures at the intake within the Delhi <br />Channel, followed by two parallel 48 -inch diameter RCPs, approximately 50 feet long each. The <br />estimated flow velocity for maximum flow of 100 cfs is estimated to be 8 feet per second (fps), and head <br />loss is estimated to be 1.7 feet. The estimated velocity and headloss for dry- weather flow of 0.4 cfs are <br />negligible. <br />Coarse - screen and Baffle Wall <br />The maximum velocity through the screen open area is 3.3 fps, assuming a clogging factor of 50 %. The <br />headloss by coarse screen for maximum flow 100 cfs is estimated to be 0.27 ft. Flow velocity through the <br />orifices after the coarse screen baffle wall is estimated to be 5 fps and headloss through orifices is 1.0 ft. <br />The estimated velocity and headloss for dry- weather flow of 0.4 cfs are negligible. <br />URS 13 <br />25F -145 <br />