Laserfiche WebLink
Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Door Closer <br />297 • As -Built Description: <br />rxeessive force required to open door. <br />PCODE ID03 <br />ADAAG 4.13.11 <br />• As- Built 10 His <br />ADA 2010 404.2.9 <br />• Proposed Solution: <br />Adjust regular door closer to accessible standards (5 <br />CBC 2010 1133B.2.5 <br />lbs max). <br />CBC 2013 10- 404.2.9 <br />Handrails <br />Sus • As -Built Descrption.: <br />PCODE ED01 <br />Handrail not provided at stairs or ramp, required on <br />both sides (not required at curb ramps or a iacent to <br />ADAAG 4.85 & 4.9.4 <br />seating areas), <br />ADA 2010 504.6 <br />• Proposed Sohition: <br />CBC 2010 1133B.4.1.1 &.5.5 <br />Provide new handrail for each side including <br />CBC 2013 1113-505.2 <br />extensions. <br />Non Fixed Table <br />299 • As -Bunt Description: <br />Accessible non -fixed table or desk (top 28" to 34" <br />PCODE IN02A <br />high; knee space at least 27" high x 19" deep x 30" <br />ADAAG 432.3 & .4 <br />wide) not provided. <br />ADA 2010 306.1 <br />• As -Built: 26" high, 12" deep to table leg <br />CBC 20110 1122B.3 & 4 <br />• Proposed Solution: <br />CBC 2013 1111-306.1 & 11B <br />Provide table or desk with accessible dimensions <br />-902.3 <br />when purchasing new furniture. <br />• Notes: <br />7x2 top <br />15x4 tops <br />4 bar <br />1 JOB <br />24 LF <br />August 27, 2014 Salty su'anson Architects, Inc. Project #14048 Survey Data - Page 70 <br />