Laserfiche WebLink
Sowers Museum Access Compliance Survey Report 1 -1 -1 <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2402 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Soo • As -Built Description: <br />At counter or bar where food or drink is served, PCODE FC04 <br />min. 60" of accessible counter, or accessible table ADAAG 5.2 <br />seating within same area, not provided. ADA 2010 226.1 <br />• As -Bunt 43.5" CBC 2010 11045.5.4 <br />• Proposed Solution: CBC 2013 I15 -226.3 <br />Provide accessible section (60" minimum length at <br />max. 34" height, with min. 27" knee space) at <br />counter. <br />I <br />301 - As -Built Description: PC4DE SAND <br />door leading into exit corridor: Where required <br />exit signs are installed, signs to provide exiting ADAAG 4.1,3(16) <br />information for people with vision impairment are ADA 2010 216.4.1 <br />not provided. CBC 2010 1011.3 <br />• Proposed Solution: CBC 2013 1IB- 216.4.1 <br />Provide raised letter /Braille "'EXIT ROI.JTE" sign at <br />door. <br />Top & Bottom Extension at Stairs <br />s+o • As -Suit Description: <br />Stair handrail does not extend horizontally 12" <br />pCCDE ED06 <br />minimum beyond top nosing, and one tread width <br />ADAAG 4,9.4(2) <br />sloped, plus 12" minimum horizontally beyond the <br />ADA2010 505.10.2; 505103 <br />bottom nosing. <br />CSC 2010 1133B.4.2.2 <br />• Proposed Solution: <br />CBC 2013 118- 505.10.2; 1 tB <br />Extend stair handrail at top and bottom. <br />- 505.10.3 <br />• Notes: <br />middle only <br />ilIIMII7 <br />HERO ] <br />August 27, 2014 S a l l y S it a n s o n Architects, Inc. P r o f e c i g 14048 Survey Data - Page 72 <br />